Mode CurrentVoltagePower consumptionCurrentMaximum air capacity RPMSound pressure level at 3 m distanceMaximum transported air temperatureProtection ratingWeightSound pressure level at 3 m distanceFan currentElectric heater powerHeat recovery efficiencyPhaseLow-noise designSound- and heat-insulated casing Frequency PowerVoltageCurrentRPMAir capacityWeightIP CodeSound pressure level at 3 mVoltageElectric heater currentTotal unit powerTotal unit currentMaximum air capacity RPMConnected air duct sizeWeightNumber of water (glycol) coil rowsPhaseFilter: extractFilter: supplyPressureSpigot sizeFrequencyFrequencyMaximum transported air temperaturePower consumptionSpeedRPMSound pressure level at 3 mConnected air duct diameterEngine TypeSpigot sizeVoltagePowerProtection rating CurrentMax. transported air temperatureMaximum air capacityMaximum unit currentMaximum unit powerFrequencyMax. unit power without electric heaterMax. unit current with electric heaterSound pressure level at 1 m Outdoor sound pressure attenuationRegenerator typeMaximum unit currentAir reach distanceRange of air streamInfluence areaSEC ClassSEC ClassMotor protection ratingEngine TypeDuct diameterHeatingEC motorWidthHeightCasing materialOutdoor mountingSound-insulated casingDuctConnection diameterDesignTypeMaterialMountingSmoke removalCurrentMax. transported air temperatureSound pressure level at 3 m distanceInsulationHeat recovery efficiencyHeat exchanger typeHeat exchanger materialLow-powered motorMaximum fan powerPM 2.5 filtration efficiencyHumidity recovery efficiencyElectric connection Electric preheater powerElectric reheater powerTransported air temperatureAir capacityHeat recovery efficiencySound pressure level at 1 m distanceTransported air temperatureFunctionsRemote control panelShutters*
- - - - - - - - - - - - - - - - - - - - 220 0.1 2400 179 0.73 IP 24 35 - - - - - - - - - - - - - - 60 - - 17 - - - - 220V / 60Hz 120 - - - - - - - - - - - - - - - - - - - - - - 120 - - - - - - - - - axial exhaust - wall mounting , ceiling mounting - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - 48 1,62 1,5 - - - - - - - - - - - - - 230 6.5 1700 8.12 350 3560 160 (150**) 67 - 1 G4 G4 (F7*) - - - 50/60 - - - - - - - - - - - - - - - - - - - - - - - - - - - A - - - - - - - aluzinc - - - - - - - - - - - - 20 mm mineral wool - counter-flow aluminium - 200 - - - - - - - up to 90 - -25 up to +40 - - - -
- - - - - - - - - - - - - - - - - - - - 220-240 0.085 2300 89 0.61 IP 24 33 - - - - - - - - - - - - - - 50/60 - - 16 - - - - - 100 - - - - - - - - - - - - - - - - - - - - - 220-240V / 50-60Hz 100 - - - - - - - - - axial exhaust - wall mounting , ceiling mounting - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - 12 1.5 2200 83 0.52 IP 34 33 - - - - - - - - - - - - - - 50/60 - - 14 - - - - - 100 - - - - - - - - - - - - - - - - - - - - - 12V / 50-60Hz 100 - - - - - - - - - axial exhaust - wall mounting , ceiling mounting - - - - - - - - - - - - - - - - - - - - - - - -
120 V - - - - - - - - - - - - - - - - - - - 127 0.175 2350 267 0.90 IP 34 38 - - - - - - - - - - - - - - 60 - - 25 - - - - - 150 - - - - - - - - - - - - - - - - - - - - - - 150 - - - - - - - - - axial exhaust - wall mounting , ceiling mounting - - - - - - - - - - - - - - - - - - - - - - - -
220 V - - - - - - - - - - - - - - - - - - - 220 0.388 2400 267 0.58 IP 34 36 - - - - - - - - - - - - - - 60 - - 16 - - - - - 150 - - - - - - - - - - - - - - - - - - - - - - 150 - - - - - - - - - axial exhaust - wall mounting , ceiling mounting - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - 220-240 0.085 2300 95 0.58 IP 34 34 - - - - - - - - - - - - - - 50/60 - - 14 - - - - - 100 - - - - - - - - - - - - - - - - - - - - - 220-240V / 50-60Hz 100 - - - - - - - - - axial exhaust - wall mounting , ceiling mounting - - - - - - - - - - - - - - - - - - - - - - - -
- - 230 162 - 249 - 62 25 +50 IP X4 7.1 - - - - - 1 - 60 - - - - - - - - - - - - - - - - - - - - 268.8 - - - - - - - - - 220V / 60Hz - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - 88 - - - - - - - - 58 - - - - - - - - - - - - - - - - - - - - - 2 2100 24 - - - 12 2.8 IP 24 0.018 58 - - - - - 41 - - - - - - - - - - - - - - - - 164x164 - - - - - - - - - - - - - - - - - - - - - - - - - - Mechanical - -
- - - - - - - - - - - - - - - - - - - - 220-240 0.085 2300 89 0.61 IP 24 33 - - - - - - - - - - - - - - 50/60 - - 14 - - - - - 100 - - - - - - - - - - - - - - - - - - - - - 220-240V / 50-60Hz 100 - - - - - - - - - axial exhaust - wall mounting , ceiling mounting - - - - - - - - - - - - - - - - - - - - - - - -
50 Hz - 1~ 220-240 42 - 230 2732 35 - IP X4 2.5 - - - - - - - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C - IP44 - 100 - - - - galvanized steel yes - for round air ducts - centrifugal - - outdoor mounting , wall mounting , Inline - 0.19 -25...+55 - - - - - yes - - - - - - - - - - - - - - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
60 Hz - 1~ 220-240 51 - 250 3258 36 - IP X4 2.5 - - - - - - - 60 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C - IP44 - 100 - - - - galvanized steel yes - for round air ducts - centrifugal - - outdoor mounting , wall mounting , Inline - 0.23 -25 +50 - - - - - yes - - - - - - - - - - - - - - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
- - - - - - - - - - - - - - - - - - - - 220-240 0.16 2400 317 0.8 IP X4 42 - - - - - - - - - - - - - - 50; 60 - - 36 - - - - - 150 - - - - - - - - - - - - - - - - - - - - - 220-240V / 50Hz or 220-240V / 60Hz 150 - - - - - - - - - axial supply and exhaust - Inline - - - - - - - - - - - - - - - - - - - - - - - -
127 V - - - - - - - - - - - - - - - - - - - 127 0.175 2350 270 0.89 IP 34 39 - - - - - - - - - - - - - - 60 - - 25 - - - - - 150 - - - - - - - - - - - - - - - - - - - - - - 150 - - - - - - - - - axial exhaust - wall mounting , ceiling mounting - - - - - - - - - - - - - - - - - - - - - - - -
220 V - - - - - - - - - - - - - - - - - - - 220 0.338 2350 270 0.89 IP 34 39 - - - - - - - - - - - - - - 60 - - 25 - - - - - 150 - - - - - - - - - - - - - - - - - - - - - - 150 - - - - - - - - - axial exhaust - wall mounting , ceiling mounting - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - 220-240 0.13 2400 232 0.81 IP 24 37 - - - - - - - - - - - - - - 50/60 - - 29 - - - - - 125 - - - - - - - - - - - - - - - - - - - - - 220-240V / 50-60Hz 125 - - - - - - - - - axial exhaust - wall mounting , ceiling mounting - - - - - - - - - - - - - - - - - - - - - - - -
127 V - - - - - - - - - - - - - - - - - - - 127 0.115 2500 - - IP 34 33 - - - - - - - 0.60 - - - - - - 60 - - 10 - - - - - 100 - - - - - - - - - - - - - - - - - - - - - 127-220 V/60 Hz 100 - - - - - - - - - axial exhaust - wall mounting , ceiling mounting - - - - - - - - - - - - - - - - 82 - - - - - - -
220 V - - - - - - - - - - - - - - - - - - - 220 0.054 2500 - - IP 34 33 - - - - - - - 0.60 - - - - - - 60 - - 9 - - - - - 100 - - - - - - - - - - - - - - - - - - - - - 127-220 V/60 Hz 100 - - - - - - - - - axial exhaust - wall mounting , ceiling mounting - - - - - - - - - - - - - - - - 82 - - - - - - -
- - 230 75 1340 1350 49 60 IP X4 14.5 - - - - 1 - 1 50 - - - - 1340 - - - - - - - - - - - - - - - - - - - - - - - - - 220В / 50Гц - - - - - - - - - - - - - - - - 9 8-11 50-95 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - 12 1.7 2300 165 0.46 IP X4 37 - - - - - - - - - - - - - - 50/60 - - 16 - - - - - 125 - - - - - - - - - - - - - - - - - - - - - 12V / 50-60Hz 125 - - - - - - - - - axial supply and exhaust - Inline - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - 220-240 0.12 2250 98 1.2 IP 24 36 - - - - - - - - - - - - - - 50/60 - - 16 - - - - - 100 - - - - - - - - - - - - - - - - - - - - - 220-240V / 50-60Hz 100 - - - - - - - - - centrifugal exhaust - wall mounting , ceiling mounting - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - 230 - - - - - - 95 - 1 ISO Coarse >60% (G4) ISO ePM1 60% (F7) - - - - - - - - - 250 - - - - - - - - - - 50/60 238 - - - 1.7 - - - - A+ - - - without heating - - - polymer coated steel - - - - - - - ceiling mounting - - - 34 25 mm, EPDM (polyurethane foam) 83-96 counter-flow polystyrene - - - - - - - -25 ... +40 510 - 44 - Wi-Fi , Filter replacement indication , Timer , Weekly schedule , External sensor connection - - -
50 Hz 0.38 - - - - - 36 - IP X4 - - - - - - - - - 61 - - - - - - - 230 - - - 260 2610 - 2.2 - 1 - - - - - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - C - - 125 - no 270 250 plastic no no for round air ducts - centrifugal exhaust , supply - Inline - - - - - - - - - - - - - - - - - - - - - - - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
60 Гц 0.4 - - - - - 37 - IP X4 - - - - - - - - - 64 - - - - - - - 230 - - - 270 2680 - 2.2 - 1 - - - - - 60 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 125 - no 270 250 plastic no no for round air ducts - centrifugal exhaust , supply - Inline - - - - - - - - - - - - - - - - - - - - - - - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
- - - - - - - - - - - - - - - - - - - - 220-240 0.085 2300 88 0.73 IP 34 33 - - - - - - - - - - - - - - 50/60 - - 14 - - - - - 100 - - - - - - - - - - - - - - - - - - - - - 220-240V / 50-60Hz 100 - - - - - - - - - axial exhaust - wall mounting , ceiling mounting - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - 83 - - - - - - - - - - - - 750 - - - 230 - - - - 3230 200 - - 1 G4 G4 , F7 - - - 50/60 - - - - - - - - - - - - - - 2.3 333 - - - - - - - - - - - A - - - - - - - painted steel - - - - - - - - - - - 26 40 mm mineral wool 72...92 counter-flow enthalpy - - - - - - - -25 ... +40 - - - - - - - -
- - - - - - - - - - - - - - - - - - - - 12 1.5 2200 78 0.6 IP 24 32 - - - - - - - - - - - - - - 50/60 - - 14 - - - - - 100 - - - - - - - - - - - - - - - - - - - - - 12V / 50-60Hz 100 - - - - - - - - - axial exhaust - wall mounting , ceiling mounting - - - - - - - - - - - - - - - - - - - - - - - -
speed 1 - - - - - - - - - - - - - - - - - - - 220-240 0.14 1350 63 - IP 55 30 - - - - - - - - - - - - - - 50 - 50 17 - - - - 220В / 50Гц 80 - - - - - - - - - - - - - - - - - - - - - - 80 - - - - - - - - - centrifugal exhaust - wall mounting , ceiling mounting - - - - - - - - - - - - 3×1.5 - - - - - - - - - - -
speed 2 - - - - - - - - - - - - - - - - - - - 220-240 0.18 1830 102 - IP 55 35.2 - - - - - - - - - - - - - - 50 - 50 27 - - - - 220В / 50Гц 80 - - - - - - - - - - - - - - - - - - - - - - 80 - - - - - - - - - centrifugal exhaust - wall mounting , ceiling mounting - - - - - - - - - - - - 3×1.5 - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 160 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - for round air ducts 160 - - stainless steel - - - - - - - - - - - - - - - - - - - - - - - - -
- 0.6 - - - - - 49 - - - - - - - - - - - 125 - - - - - - - 230 - - - - 2235 100 26 - 1 G4 G4 , F8 - - - 50/60 - - - - - - - - - - - - - - - - - - - - - - - - - - - D - - - - - - - polymer coated steel - - - - - - - - - - - - 5 mm, 10 mm polyurethane foam 72...87 cross-flow enthalpy - - 93 27...47 - - - -5...+40 230 - - - - - - -