Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use

VENTS Quiet 100 DC VTH

  • Description
  • Characteristics
  • Downloads
  • Options
  • Dimensions
Description
Description
APPLICATIONS  
  • Innovative extract fan with stylish design for enhanced comfort level in shower rooms, bathrooms, kitchens and other residential premises.
  • Maximum air flow combined with low noise level provide the ideal microclimate.
  • Mounting into ventilation shafts or connection to Ø 100 mm air ducts.
  • Two-speed operation modes with max. air capacity 100 m3/h.
DESIGN  
  • The casing and the impeller are made of high-quality and durable UV-resistant plastic.
  • The specially designed aerodynamic profile of the mixed-flow impeller provides high air capacity and pressure combined with low-noise operation.
  • A shortened spigot for mounting into a ventilation shaft or direct connection to Ø 100 mm air duct.
  • The fan is equipped with a specially designed backdraft damper to prevent back flow and heat losses during the fan standby.
  • The fan exhaust spigot incorporates specially designed air rectifiers to reduce air turbulance, noise level and boost air pressure.
  • High ingress protection rating makes the fan the ideal solution for ventilation of a bathroom.
  • The electronic components are protected with tight covers.
MOTOR  
  • Low energy demand max 3.5 W due to a new high-efficient motor.
  • Maintenance-free bearings contain enough grease for 40 000 hrs non-stop operation.
  • Motor equipped with electric overheating protection.
Operation modes of 100 Quiet DC fan with an integrated turn-off delay timer, humidity sensor and motion sensor.
 Operation mode selection and setup for 100 Quiet DC models with modifications TTHVTHTP is performed by setting the DIP switch to a respective position. 

Mode 1 (single-speed mode)

  • The fan is turned off by default. The fan starts operating at the low speed when the switch is closed or one of the sensors is activated.

Mode 2 (single-speed mode)

  • The fan is turned off by default. The fan starts operating at the high speed when the switch is closed or one of the sensors is activated.

Mode 3 (two-speed mode)

  • The fan operates at the low speed by default. The fan switches to the high speed when the switch is closed or the sensors are activated.

Mode 4 (two-speed mode)

  • The fan is turned off by default. The fan starts operating at the low speed when the switch is closed and switches to the high speed when the humidity or motion sensor is activated.
CONTROL  

Manual control:

  • Manual operation with a room light switch. The switch is not included in the delivery set.
  • Operation with the integrated pull cord switch V. Not applied in case of ceiling mounting.

Automatic control:

  • With the electronic control unit BU-1-60 (see Electrical Accessories). The control unit is supplied separately.
  • With the turn-off delay timer T. The built-in turn-off delay timer enables operation of the fan within 2 up to 30 minutes after turning the fan off with a switch.
  • With the humidity sensor and timer TH. If the indoor humidity exceeds the set humidity point adjustable from 60% to 90%, the fan switches automatically to the high speed and operates until the humidity level drops below the set point. After that the fan continues operating according to the timer settings and turns either to the low speed or turns off.
  • With the motion sensor and the timer TP. If the motion sensor detects motion in the reach area up to 4 m with a viewing angle up to 100°, the fan turns on and operates from 2 to 30 minutes according to the timer settings.

MOUNTING FEATURES

 
  • Installation directly inside a ventilation shaft.
  • Flexible air ducts may be used in case of remote location of the ventilation shaft. The air duct is connected to the exhaust spigot with a fixing clamp.
  • Wall mounting with screws.
  • Suitable for ceiling mounting.
Characteristics
Characteristics
Parameter max min Measurement unit
Voltage 230 230 V
Frequency 50/60 50/60 Hz
Power consumption 3.6 1.7 W
Air capacity 100 70 m³/h
Current 0.137 0.063 A
RPM 2150 1800 min-1
Sound pressure level at 3 m 26.5 22 dBА
Weight 0.55 0.55 kg
Spigot size 100 100 mm
Engine Type 220V / 50-60Hz 220V / 50-60Hz -
Design axial axial -
Duct diameter 100 100 mm
IP Code IP 45 IP 45 -
Type exhaust exhaust -
Mounting wall mounting , ceiling mounting wall mounting , ceiling mounting -
Files archieve
Downloads
Modifications
Modifications
Modification name Backdraft damperHumidity sensorTimerPull-cord switchDC Motor
VENTS Quiet 100 DC VTH
+
Dimensions
Characteristics
VENTS Quiet 100 DC
Parameter Value Measurement unit
Ø D 99 mm
B 158 mm
H 136 mm
L 81 mm
L1 26 mm
Legend
Legend
Picture symbol   Designation   Modification description
  Quiet DC T   Modification with a turnoff delay timer regulated from 2 up to 30 minutes. All the Quiet DC fans have this timer by default.
  Quiet DC TH   Modification with a turn-off delay timer regulated from 2 up to 30 minutes and a humidity sensor with an adjustable threshold from 60% to 90%.
  Quiet DC VT   Modification with a pull cord switch and a turn-off delay timer regulated from 2 up to 30 minutes.
  Quiet DC VTH   Modification with a pull cord switch, a turn-off delay timer regulated from 2 up to 30 minutes and a humidity sensor with an adjustable threshold from 60% to 90%.
  Quiet DC TP   Modification nwith a turn-off delay timer regulated from 2 up to 30 minutes and a motion sensor with reach distance up to 4 m and viewing angle up to 100°.
Share your opinion

Questionnaire
Basic parameter for domestic fan selection