VENTS AOE 18

  • Description
  • Characteristics
  • Downloads
  • Dimensions
  • Designation key
Description
Description

APPLICATION

  • Designed for air heating in the room with electric heater and air uniform distribution due to an integrated fan and louvre shutters.
  • The air heating units enable quick air heating of large premises or provide local heating of a work zone, for example, in big airplane shed or production facilities.
  • The air heating units are designed for installation in manufacturing workshops, garages, car showrooms, stock houses, trade facilities, super- and hypermarkets, shops, sport halls, conference halls, poultry and cattle farms, greenhouses and other similar premises.
  • The unit design enables quick and easy mounting and its operation reduces total investment costs for heating system.

DESIGN

  • The AOE unit consists of an axial fan and an electric heater enclosed into a steel polymer coated casing.
  • The electric heater is equipped with two overheating thermostats:
    • the main overheating protection with automatic reset is activated at +50 °C. After the heater cooling the thermostat closes the heater control circuit.
    • the alarm overheating protection with manual reset is activated at +90 °C. In case of alarm thermostat activation power supply to the heater is posible after manual alarm reset only.

FAN MOTOR

  • AC motors with external rotor and built-in thermal overheating protection with automatic reset.

ADVANTAGES OF AIR HEATING:

  • quick temperature increase in the room up to set point;
  • low inertance of the system allows to provide alternating heating mode or heating in some zones;
  • high heating efficiency;
  • capital investments for air heating system is much less as compared to the similar water heating system.

CONTROL AND REGULATION

  • For safe and correct operation the air heating unit must be controlled with integral control and protection automatic control system to provide the following functions:
    • automatic power and heating temperature adjustment;
    • power supply cut-off to the heater in case of the fan shutdown, low air flow or if integrated motor overheating thermostats are activated;
    • air supply to the electric heating elements for heating removal after shutoff of the heating unit;
    • power supply to the heater via an integrated automatic circuit breaker with tripping current depending on the heater power.
  • The heating unit operation modes are controlled from UET-15D or UET-30D (available upon separate order) control unit.

  • Air flow temperature is controlled by the heater on/off switch time (full heating power) in compliance with a set heating point.
  • The control unit controls the fan speed and cuts off power supply to the heater in case of the fan shutdown or very low air flow.
  • The control unit is designed for joint operation with digital TST-1-300 thermostats with sensor display (TSTD-1-300 model is equipped with a remote controller) or RTS-1-400 with LCD display (RTSD-1-400 is equipped with a remote controller). The thermostats are available on separate order.
  • The thermostat is designed for indoor installation in the room heated by the air heating unit to determine its operation mode.
  • The thermostat installation place must not be influenced by windows, doors and heating radiators.
  • One thermostat is capable to control several connected air heating units in one room (max. 10 AOE units per each thermostat).

ACCESSORY SELECTION TABLE:

 
Air heating unit model Control unit Digital thermostat Mounting accessories
    with sensor display with LCD display Mounting angles Mounting brackets
 
АОЕ 9 UET-15D

TST-1-300

TSTD-1-300

RTS-1-400

RTSD-1-400

MKP-AOW MK-AOW 25
АОЕ 12
АОЕ 15
АОЕ 18 UET-30D MK-AOW 45
АОЕ 24
АОЕ 30

WARM AIR DISTRIBUTION

MOUNTING WARNING!
  • The air heating unit is suitable for vertical installation on the walls (beams) or horizontal installation on the ceiling (beams).
While mounting AOE units provide free air supply to the fan suction vent by keeping the minimum distance from the units to the wall or ceiling 300 mm.
Characteristics
Characteristics
Parameter AOE 18
Measurement unit
Voltage Voltage 400 V
Frequency 50 Hz
Fan power 253 W
Fan current 1.1 A
Total unit power 18250 W
Total unit current 27.1 A
Air capacity 4000 m³/h
Air capacity 4000 m³/h
Sound pressure level at 3 m Sound pressure level at 3 m 61 dBА
Protection rating Protection rating IP 21 -
Phase Phase 3 -
Weight Weight 48 kg
Electric heater power Electric heater power 18000 W
Electric heater current Electric heater current 26 A
Casing material Casing material -
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
"VENTS AOE" product description 05-2023 (pdf 1.24Mb)
Download high quality image "VENTS AOE (front view)" (psd 2.6Mb)
Download image "VENTS AOE (front view)" for your website (png 584.55Kb)
"Air heating (cooling) units" product description 05-2013 (pdf 2.43Mb)
"Control unit for VENTS AOE" user's manual 10-2020 (V98-1EN-01) (pdf 2.37Mb)
"VENTS AOE" user's manual 01-2021 (V98EN-01) (pdf 2.72Mb)
Download high quality image "VENTS AOE (back view)" (psd 2.72Mb)
Download image "VENTS AOE (back view)" for your website (png 647.98Kb)
Dimensions
Characteristics
VENTS AOE 18
Parameter Value Measurement unit
Designation key