VENTS DuoVent 250 EC


Centrifugal fan in a metal casing for round air ducts. Air flow up to 1390 m³/h.

  • Description
  • Characteristics
  • Capacity diagram
  • Downloads
  • Dimensions
  • Additional characteristics
  • Designation key
Description
Description
APPLICATION
  • Exhaust ventilation systems for commercial, office and other public or industrial premises with limited installation space.
  • The DuoVent EC fan ensures uninterrupted ventilation operation: if one fan fails, the second fan automatically switches on.
  • The modes are controlled by the controller, which is not included in the delivery set and must be ordered separately.
  • Designed for connection to round air ducts with a diameter of 150 to 400 mm.
DESIGN
  • The fan casing is made of galvanized sheet steel using heat- and sound-insulation material.
  • The air damper allows adjusting the direction of air flow.
  • Controlled by the air flow.
  • The round connecting spigots are rubber sealed.
  • The hinged cover gives free access to the motors, simplifies installation and maintenance of the fans and ducts without dismantling.
ELECTRIC MOTORS
  • The unit is equipped with high-efficient electronically commutated (EC) DC motors with mixed-type impellers.
  • These state-of-the-art motors are the most advanced solution in energy efficiency today.
  • The motors are equipped with built-in overheating protection.
  • Ball bearings in the motor ensure long service life (40 000 hours).
  • To achieve accurate performance, low noise levels and safe fan operation, each turbine is dynamically balanced during assembly.
  • The motor ingress protection rating is IP44.
IMPELLER
  • Thanks to the improved mixed-type impeller, which is a hybrid of axial and centrifugal impeller, the DuoVent EC unit has low power consumption and noise level with high performance.
  • The diffuser, the specially profiled impeller and the directing vanes at the outlet of the fan casing distribute air flow in such a way as to attain the best combination of high performance and high pressure at low noise level.
CONTROLLER
  • Allows tracking the motor failures and signalling them, as well as automatically switching the unit to work with a functioning motor.
  • The controller is not included in the delivery set and must be ordered separately.
Controller functions:  
  • Automatic alternation of the active fan with preset switching period.
  • Forced constant operation of the fan A.
  • Forced constant operation of the fan B.
  • Fan alarm. The failed fan is switched off, the second fan is switched on. The controller generates an error signal and corresponding indication.
  • Fan speed control.
  • Boost mode increases the performance of the fan. It is possible to set the time during which the fan will run in this mode.
  • Test mode. Automatic alternation of the active fan with a period from 1 to 12 min.
  • Checking motors at start-up.
  • Possibility of connection to BMS.
  • Possibility of connecting an external 0-10 V sensor.
  • Possibility of connecting external devices (10 V and 24 V).
MOUNTING
  • The duct fans are intended for mounting to round air ducts.
  • The fans are installed between the air ducts.
  • While mounting the fan provide enough access for servicing and repair operations.
Characteristics
Characteristics
Parameter DuoVent 250 EC
Measurement unit
Phase 1 ˜
Voltage 220-240 V
Fan current 1.29 A
Frequency 50/60 Hz
Power consumption 170 W
Maximum air capacity 386 l/s
Maximum air capacity 1390 m³/h
RPM 3282 min-1
Sound pressure level at 3 m 49 dBА
Protection rating IP X4 -
Motor protection rating IP54 -
Duct diameter 250 mm
Transported air temperature -25 ... +55 °С
Sound- and heat-insulated casing yes -
Casing material galvanized steel -
Weight 47 kg
Duct for round air ducts -
Type exhaust -
Mounting Inline -
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
"VENTS DuoVent EC" product description 07-2023 (pdf 977.37Kb)
Download high quality image "VENTS DuoVent EC (ErP 2018)" (psd 3.76Mb)
Download image "VENTS DuoVent EC (ErP 2018)" for your website (png 247.71Kb)
"VENTS DuoVent (EC)" user's manual 01-2023 (V256EN-05) (pdf 1.17Mb)
Dimensions
Characteristics
VENTS DuoVent 250 EC
Parameter Value Measurement unit
∅D 249 mm
H 417 mm
L 1062 mm
L1 939 mm
W 887 mm
W1 806 mm
Additional characteristics
Additional characteristics
A-weighted sound power level Octave frequency band [Hz] LpA, 3 m dBA LpA, 1 m dBA
  Hz Gen. 63 125 250 500 1000 2000 4000 8000
LwA to inlet dBA 72 47 67 69 56 47 44 48 39 51 61
LwA to outlet dBA 73 44 65 72 57 44 42 49 43 52 62
LwA to environment dBA 70 49 68 65 52 44 38 38 31 49 59
Designation key
Designation key
Series Spigot diameter [mm] Motor type
VENTS DuoVent: sound-insulated fan for round air ducts with two motors 150; 200; 250; 315; 350; 400 EC: synchronous electronically commutated motor