VENTS KSD 250-4E
- Description
- Characteristics
- Downloads
- Dimensions
- Legend
APPLICATIONS | |
|
|
DESIGN | |
|
|
MOTOR | |
|
|
SPEED CONTROL | |
|
|
MOUNTING | |
|
|
The fan with electronic temperature and control module (U option)
|
|
|
|
|
|
Control logic of the fan with the electronic temperature and speed control module
|
|
|
|
There are two switch delay patterns for various cases: | |
|
|
Example for temperature sensor delay: | Example for timer delay: |
|
|
|
|
↓ | ↓ |
|
|
↓ | ↓ |
|
|
↓ | ↓ |
|
|
↓ | ↓ |
|
|
↓ | |
|
|
↓ | |
|
|
↓ | |
|
|
|
Parameter |
KSD 250-4E |
Measurement unit |
---|---|---|
Number of intake spigots | 1 | - |
Exhaust flange diameter | 250 | - |
Intake flange diameter | 250 | - |
Highpowered motor | no | - |
Phase | 1 | ˜ |
Voltage | 230 | V |
Frequency | 50 | Hz |
Sound pressure level at 3 m distance | 44 | dBА |
Power consumption | 243 | W |
Current | 1.06 | A |
Maximum air capacity | 1520 | m³/h |
RPM | 1320 | min-1 |
Max. transported air temperature | -20 +50 | °С |
Protection rating | IP X4 | - |
Design | centrifugal | - |
Weight | 30 | kg |
Number of poles | 4 | - |
Sound- and heat-insulated casing | yes | - |
Casing material | galvanized steel | - |
Duct | for round air ducts | - |
Type | supply and exhaust | - |
Mounting | Inline | - |
Parameter | Value | Measurement unit |
---|---|---|
∅D | 248 | mm |
∅d | 20 | mm |
B | 453 | mm |
B1 | 400 | mm |
H | 433 | mm |
H1 | 298 | mm |
H2 | 216 | mm |
H4 | 470 | mm |
L | 568 | mm |
L1 | 470 | mm |
L2 | 400 | mm |
Series | Exhaust flange diameter [mm] | Intake flange diameter [mm] * | Number of intake flanges | Number of poles | Phase | Options |
VENTS KSD |
250; 315 | 250 | 2 | 4; 6 | E - single phase | S - high-powered motor; R - power cord with IEC C14 electric plug; U – speed controller with electronic thermostat and temperature sensor integrated into the air duct. Equipped with power cord and IEC C14 electric plug. Temperature-based operation logic; Un – speed controller with electronic thermostat and external temperature sensor fixed on 4 m cable. Equipped with power cord and IEC C14 electric plug. Temperature-based operation logic; U1 – speed controller with electronic thermostat and temperature sensor integrated into the air duct. Equipped with power cord and IEC C14 electric plug. Timer-based operation logic; U1n – speed controller with electronic thermostat and external temperature sensor fixed on 4 m cable. Equipped with power cord and IEC C14 electric plug. Timer-based operation logic. |
* no intake flange diameter if it is equal to the exhaust flange diameter