Description
APPLICATION DESIGN
  • The LF series actuators with actuating torque 4 Nm are designed for controlling air dampers with cross section up to 0.8 m² installed in various ventilation and air conditioning systems and performing protection functions, as freezing protection, smoke detection, etc.
  • The actuator moves the damper to its operating position while tensioning the return spring at the same time.
  • In case of power supply cut-off, the damper moves back to its safe position by the spring energy.
  • The actuator is installed directly on the damper axis and locked with a special spindle clamp to prevent its turning-through.
  • The actuator overload protection stops the actuator once it reaches the end positions.
  • The turning angle may be adjusted by a mechanical end stop.
Characteristics
Characteristics
Parameter LF24
Measurement unit
Voltage Voltage AC/DC 24 V
Frequency Frequency 50/60 Hz
Nominal voltage range Nominal voltage range

AC 19,2…28,8 / DC 21,6…28,8

V
Rated power Rated power 7 (макс. I 5,8 А при t = 5 мс) VA
Power consumption in operation Power consumption in operation 5 W
Power consumption at rest Power consumption at rest 2.5 W
Connecting cable Connecting cable

1 m long, 2 x 0.75 mm2

-
Rotation direction Rotation direction выбирается установкой L/R -
Torque motor Torque motor 4 (при номинальном напряжении) Nm
Torque spring Torque spring 4 Nm
Rotation angle: Rotation angle:

max. 95°, adjustable 37…100% with a mechanical end stop

-
Running time motor Running time motor

40…75 (0…4 Nm)

sec
Running time spring Running time spring

~20 at -20…50 °C

sec
Service life Service life 60 000 срабатываний -
Protection rating Protection rating IP 54 -
Electrical protection class Electrical protection class -
Operation temperature Operation temperature -30...+50 °С
Storage temperature Storage temperature -40…+80 °С
Ambient humidity Ambient humidity 95%, без конденсации -
Noise level motor Noise level motor 50 dBА
Noise level spring Noise level spring ~62 dBА
Maintenance Maintenance not required -
Weight Weight 1.4 kg
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
"BELIMO LF230/LF24" product description 02-2020 (pdf 213.67Kb)
Download image "BELIMO LF230/LF24" for your website (png 556.22Kb)
Download high quality image "BELIMO LF230/LF24" (psd 1.81Mb)
Dimensions
Characteristics
VENTS LF24
Parameter Value Measurement unit
Wiring plan
Wiring plan

Share your opinion

Questionnaire
How often do you use equipment selection program?