VENTS MPA 1800 E3


Supply unit with the air flow up to 2000 m³/h in the compact sound- and heat-insulated casing with electric heater

  • Description
  • Characteristics
  • Downloads
  • Dimensions
  • Additional characteristics
  • Designation key
  • Accessories
Description
Description
DESCRIPTION CASING
  • Air supply MPA unit is a complete ventilation unit for air filtration, air heating and supply to premises.
  • Steel casing covered with aluzinc coating internally filled with 25 mm heat- and sound-insulating layer made of mineral wool.
FILTER HEATER
  • Integrated panel G4 filter ensures sufficient supply air purification.
  • Electric heater is used for heating of supply air in cold season.
FAN CONTROL AND AUTOMATION
  • Centrifugal double-inlet fan with forward curved blades and built-in overheating protection with automatic restart.
  • The ball bearings in the electric motor are maintenance free and designed for at least 40,000 hours operation.
  • Integrated control and automation system for threespeed (air flow) control and setting supply air temperature.
  • The unit may be controlled from the external control panel fixed on 10 m wire delivered as a standard.
MPA...E CONTROL AND PROTECTION FUNCTIONS  
  • Switching the unit on/off from the control panel.
  • Setting the supply air temperature from the remote control panel and maintaining it by the triac heater control.
  • Fan speed control from the control panel.
  • Tracking the set operating control logic while turning the unit on and off.
  • Unit operation according to daily and week schedule.
  • Overheating protection of the electric heating elements.
  • Disabling electric heater operation when the fans are not running.
  • Electric heater overheating protection by two overheating thermostats, one thermostat activated at 60 °C with automatic reset and another thermostat activated at 90 °C with automatic reset.
  • Actuating the air damper.
  • Input for alarm fire fighting signal.
  • Input from external humidity sensor, CO2 sensor, etc (normally opened dry contact). On sensor’s output signal the unit switches to the maximum speed.
MOUNTING  
  • The supply unit can be mounted on the floor, suspended to the ceiling by means of a seat angle with a flexible connector or fixed to the wall using brackets.
  • The unit can be installed either in such service spaces as balcony, storeroom, basement, roof space or in main premises above the suspended ceiling, in the pocket or placed directly in the room.
  • The unit can be mounted in any position but the vertical one with air downstream because the heating elements are not allowed under the fan.
  • Access for the unit maintenance and filter cleaning shall be provided.
OFFICE VENTILATION EXAMPLE  
  • Air supply and exhaust ventilation in the modern office can be arranged as follows.
  • Air handing MPA unit, exhaust fan complying with MPA unit characteristics, intake and exhaust main air ducts are mounted in the hall behind the suspended ceiling.
  • The branchings are laid into the office premises and air distribution units. Intake air from outside flows through the external grille, is filtered in the air handling unit, heated to the required temperature and supplied to the office rooms through the branch duct system.
  • Exhaust air is extracted outside through the external grille by means of the exhaust fan.
  • Thus the office has the permanent fresh air supply, controllable air exchange, no draughts when opened windows, no dust and no noise.
MPA unit office air exchange example
Characteristics
Characteristics
Parameter MPA 1800 E3
Measurement unit
Frequency 50 Hz
Phase 3 ˜
Voltage 400 V
Maximum fan power 490 W
Electric heater power 18000 W
Total unit power 18490 W
Fan current 2.15 A
Electric heater current 26.0 A
Total unit current 28.15 A
Air capacity 2000 m³/h
RPM 1100 min-1
Noise level at 3 m 40 dBА
Transported air temperature -25 ... +40 °С
Heating electric heating -
Casing material aluzinc -
Insulation 25 mm mineral wool -
Filter G4 -
Connected air duct size 500х250 mm
Weight 61.5 kg
Outdoor mounting no -
Duct for rectangular air ducts -
Type supply -
Mounting floor mounting, wall mounting, ceiling mounting -
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
"VENTS MPA...E, MPA...W" product description 01-2023 (pdf 5.26Mb)
Download high quality image "VENTS MPA...E (ErP 2016, 2018)" (psd 3.28Mb)
Certificate GS "MPA (230V)" (pdf 180.41Kb)
Certificate GS "MPА (3-400V)" (pdf 183.89Kb)
Declaration of сonformity "MPA" (pdf 1.55Mb)
"VENTS MPA E" user's manual 08-2021 (V27EN-04) (pdf 3.95Mb)
Certificate LVD "MPA (230V)" (pdf 227.41Kb)
Certificate LVD "MPА (3-400V)" (pdf 227.69Kb)
Download image "VENTS MPA...E (ErP 2016, 2018)" for your website (png 411.28Kb)
Dimensions
Characteristics
VENTS MPA 1800 E3
Parameter Value Measurement unit
B 500 mm
B1 520 mm
B2 649 mm
B3 600 mm
H 250 mm
H1 270 mm
H2 480 mm
L 800 mm
L1 680 mm
L2 mm
Additional characteristics
Additional characteristics
Sound-power level Octave-frequency band [Hz]
  Hz Gen 63 125 250 500 1000 2000 4000 8000
LwA to inlet dBA 74 79 76 74 67 67 64 64 54
LwA to outlet dBA 75 82 78 74 68 73 66 70 67
LwA to environment dBA 52 64 62 54 48 44 40 36 34
Designation key
Designation key
Series Rated air flow, m³/h Heater type Phase Integrated control system
VENTS MPA 800; 1200; 1800; 2500; 3200; 3500; 5000 Е: electric;
W: water
1: single phase;
3: three phase
LCD: integrated automation with A16 control panel
Accessories
Accessories
Type Replaceable filter Filter type
MPA 800 E1 SF 442x275x47 G4 panel filter
MPA 1200 E3
MPA 1800 E3 SF 390x545x47 G4 panel filter
MPA 2500 E3
MPA 3200 E3 SF 653x440x47 G4 panel filter
MPA 3500 E3