VENTS MPA 5000 W
Supply unit with the air flow up to 6500 m³/h in the compact sound- and heat-insulated casing with water heater
- Description
- Characteristics
- Downloads
- Dimensions
- Additional characteristics
- Hot water coil parameters
- Designation key
- Accessories
Description
Description
DESCRIPTION | CASING |
|
|
FILTER | HEATER |
|
|
FAN | CONTROL AND AUTOMATION |
|
|
MPA...W CONTROL AND PROTECTION FUNCTIONS | |
|
|
MOUNTING | |
|
|
OFFICE VENTILATION EXAMPLE | |
|
|
MPA unit office air exchange example |
Characteristics
Characteristics
Parameter |
MPA 5000 W |
Measurement unit |
---|---|---|
Frequency | 50 | Hz |
Phase | 3 | ˜ |
Voltage | 400 | V |
Maximum fan power | 1800 | W |
Fan current | 4.5 | A |
Total unit power | 1800 | W |
Total unit current | 4.5 | A |
Air capacity | 6500 | m³/h |
Number of water (glycol) coil rows | 4 | - |
RPM | 1400 | min-1 |
Noise level at 3 m | 55 | dBА |
Transported air temperature | -25 ... +40 | °С |
Casing material | aluzinc | - |
Filter | G4 | - |
Insulation | 25 mm mineral wool | - |
Connected air duct size | 800х500 | mm |
Weight | 136 | kg |
Outdoor mounting | no | - |
Duct | for rectangular air ducts | - |
Type | supply | - |
Mounting | floor mounting, wall mounting, ceiling mounting | - |
Files archieve
Downloads
Select document type
"Control system for air supply and air handling units based on Freemax controllers and AC208A2 sensor control panels" user's manual 07-2023 (V99EN-03) (pdf 7.14Mb)
Dimensions
Characteristics
Parameter | Value | Measurement unit |
---|---|---|
B | 800 | mm |
B1 | 820 | mm |
B2 | 971 | mm |
B3 | 925 | mm |
H | 500 | mm |
H1 | 520 | mm |
H2 | 670 | mm |
L | 1299 | mm |
L1 | 720 | mm |
L2 | 360 | mm |
Additional characteristics
Additional characteristics
|
Hot water coil parameters
Hot water coil parameters
How to use water heater diagrams
System Parameters: Air flow = 6000 m³/h. Outside air temperature = -25 °C. Water temperature (in/out) = 70/50 °C.
- Air Speed. Starting from 6000 m³/h on the air flow scale draw a vertical line ① till the air speed axis which makes about 4.15 m/s.
- Supply air temperature. Prolong the line ① up to the point where it crosses the outside air temperature (blue curve), e.g. -25 °C; then draw a horizontal line ② from this point to the left till crossing water in/out temperature curve (70/50 °C). From this point draw a vertical line ③ to the supply air temperature axis on top of the graphic (+27 °C).
- Heating coil capacity. Prolong the line ① up to the point where it crosses the outside air temperature -25 °C (red curve) and draw a horizontal line ④ from this point to the right until it crosses water in/out temperature curve (70/50 °C), from here draw a vertical line ⑤ up to the scale representing the heating coil capacity (121 kW).
- Water flow. Prolong the line ⑤ down to water flow axis at the bottom of the graphic ⑥ (1.52 l/s).
- Water pressure drop. Draw the line ⑦ from the point where line ⑥ crosses the black curve to the pressure drop axis. (31.0 kPa).
Designation key
Designation key
Series | Rated air flow, m³/h | Heater type | Integrated control system |
VENTS MPA | 800; 1200; 1800; 2500; 3200; 3500; 5000 | W: water | LCD: integrated automation with A16 control panel |
Accessories
Accessories
Type | Replaceable filter | Filter type |
MPA 800 W | SF 442x275x47 G4 | panel filter |
MPA 1200 W | ||
MPA 1800 W | SF 390x545x47 G4 | panel filter |
MPA 2500 W | ||
MPA 3200 W | SF 653x440x47 G4 | panel filter |
MPA 3500 W | ||
MPA 5000 W | SFK 868x573x27 G4 | pocket filter |
Accessories
Similar products