VENTS OKW 400x200-3

  • Description
  • Characteristics
  • Downloads
  • Dimensions
  • Additional diagrams
  • Legend
Description
Description
APPLICATION

Duct water coil air coolers are designed for cooling of supply air in rectangular ventilation systems and can be applied in supply or supply and exhaust ventilation systems.

DESIGN

The water coolers are available in OKW and OKW1 mofications. The OKW1 cooler has a simplified design.

The cooler casing is made of galvanized sheet steel, the manifold is made of copper tubes and the heat exchange surface is made of aluminium plates. The cooling coils are available in 3 rows modification and designed for the maximum operating pressure 1.5 MPa (15 bar). It is equipped with a droplet separator and a drain pan for condensate collection and removal.

For OKW and OKW1 models by default the service side is located on the right side from the air stream direction. The OKW cooler service side location can be changed by coil turning by 180°. The OKW1 modification does not have this option.

MOUNTING
  • Mounting is effected by means of flange connection. The water cooling coils can be installed only horizontally to enable the unit deaeration and condensate draining.
  • The installation shall be performed in such a way as to enable the uniform air distribution along the entire cross section.
  • The air filter shall be installed at the cooler inlet to protect the cooler against dirt and dusting.
  • The cooler can be installed both at the fan inlet or outlet. If the cooling coils are located at the fan outlet the air duct between the cooler and the fan shall have the lehgth 1 to 1.5 m to ensure the air flow stabilization.
  • To attain the maximum cooling capacity the cooler must be connected on counter-flow basis. All the nomographic charts in the catalogue are valid for such connection.
  • If water serves as a cooling agent, the coolers are suitable for indoor installation only in the premises with the indoor temperature not below 0 °C. For outdoor installation use an antifreeze mixture, i.e.ethylene glycol solution.
  • The droplet separator is made of polypropylene profile and prevents condensate dripping from the cooling tubes by the cooling air flow. While selecting a cooler type consider that the most suitable speed of the air flow for the efficient droplet separator operation is up to 4 m/s.
  • Condensate drain from the cooler shall be performed through the U-trap. The U-trap height depends on the total pressure in the fan and can be calculated using the figures and the table below.

 


H (mm) K (mm) P (Pa)
100 55 600
200 105 1100
260 140 1400

 

  

Н - U-trap height

К - drain height

Р - total pressure in the fan

  • To ensure the correct and safe cooler operation use the automation system providing the complex control and automatic regulation of the cooling capacity and air cooling temperature.
Counter flow connection Parallel flow connection

Air pressure loss in water coolers 

Rectangular OKW series

Characteristics
Characteristics
Parameter OKW 400x200-3
Measurement unit
Casing material Casing material -
Rectangular duct size Rectangular duct size 400х200 mm
Width 400 mm
Height 200 mm
Weight 10.4 kg
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
"OKW, OKW1" product description 02-2016 (pdf 7.2Mb)
Download high quality image "OKW" (psd 1.69Mb)
"OKW, OKW1, OKF, OKF1" user's manual 01-2024 (V63EN-05) (pdf 2.14Mb)
Download image "OKW" for your website (png 345.61Kb)
Dimensions
Characteristics
VENTS OKW 400x200-3
Parameter Value Measurement unit
B 400 mm
B1 420 mm
B2 440 mm
B3 470 mm
H 200 mm
H1 220 mm
H2 240 mm
H3 295 mm
H4 124 mm
L 56 mm
K G 3/4'' mm
Additional diagrams
Additional diagrams

How to use water cooling coils diagrams:

Air Speed.  Starting from 900 m3/h on the air flow scale draw a vertical line 1 till the air speed axis. It makes 3.2 m/s.

  • Supply air temperature. Prolong the line 1 up to the point where it crosses the outside air temperature (e.g. +32°C); then draw a horizontal line 2 from this point to the left till  crossing  the outside air humidity (e.g. 50%). From this point draw a vertical line 3 to the supply air temperature at cooler outlet axis on top of the graphic (+20.1°C).
  • Cooling capacity. Prolong the line 1 up to the point where it crosses the outside air temperature (e.g. +32°C) and draw a horizontal line 4 from this point to the right until it crosses the outside air humidity curve (e.g., 50%), from here draw a vertical line 5 up to the scale representing the cooler capacity (6.5 kW).
  • Water flow. Prolong the line 5 down to water flow  axis at the bottom of the graphic 6 (0.26 l/s).
  • Water pressure drop. Draw the line 7 from the point where the line 6 crosses the black curve to the pressure drop axis (15.0 kPa).

Legend
Legend
Series   Flange designation (WxH) [mm]   Number of cooling coils
OKW
  400х200; 500х250; 500х300; 600х300; 600х350; 700х400; 800х500; 900х500; 1000х500   3
Accessories