VENTS TT 125 S
- Description
- Characteristics
- Downloads
- Dimensions
- Additional characteristics
- Designation key
- BIM
Description
Description
APPLICATION | |
|
|
DESIGN | |
|
|
|
|
MOTOR | |
|
|
SPEED CONTROL | |
|
|
MOUNTING | |
|
|
THE FAN WITH ELECTRONIC MODULE OF THE TEMPERATURE SENSOR AND SPEED CONTROLLER (U OPTION) | |
|
|
OPERATING LOGIC OF THE FAN WITH THE ELECTRONIC MODULE OF THE TEMPERATURE SENSOR AND SPEED CONTROLLER | |
|
|
There are two switch delay patterns for various cases: | |
|
|
TT FANS APPLICATIONS | |
bathroom ventilation example | office ventilation example |
parallel installation of fans in the storehouse to increase the air capacity |
Characteristics
Characteristics
Parameter |
TT 125 S min |
TT 125 S max |
Measurement unit |
---|---|---|---|
Voltage | 1~230 | 1~230 | V |
Frequency | 50/60 | 50/60 | Hz |
Current | 0.14 | 0.27 | A |
Sound pressure level at 3 m distance | 31 | 42 | dBА |
Power consumption | 32 | 60 | W |
Maximum air capacity | 295 | 440 | m³/h |
RPM | 1850 | 2510 | min-1 |
Maximum transported air temperature | -25 +60 | -25 +60 | °С |
Protection rating | IP X4 | IP X4 | - |
Design | mixed-flow | mixed-flow | - |
Weight | 3.14 | 3.14 | kg |
Duct diameter | 125 | 125 | mm |
Casing material | plastic | plastic | - |
SEC Class | C | C | - |
Duct | for round air ducts | for round air ducts | - |
Mounting | Inline | Inline | - |
* | To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). | To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). | - |
Files archieve
Downloads
Select document type
Dimensions
Characteristics
Parameter | Value | Measurement unit |
---|---|---|
∅D | 123 | mm |
B | 223 | mm |
H | 250 | mm |
L | 295 | mm |
Additional characteristics
Additional characteristics
Sound power level, A-filter applied | Sound pressure level at 3 meters, A-filter applied | Sound pressure level at 1 meters, A-filter applied | ||||||||||
Gen. | Octave-frequency band [Hz] | |||||||||||
Hz | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 | LpA, 3 m [dBA] | LpA, 1 m [dBA] | ||
Min speed | ||||||||||||
LwA to inlet | dBA | 56 | 28 | 38 | 53 | 51 | 49 | 46 | 37 | 24 | 36 | 46 |
LwA to outlet | dBA | 55 | 27 | 37 | 52 | 50 | 48 | 45 | 37 | 23 | 35 | 45 |
LwA to environment | dBA | 52 | 23 | 33 | 47 | 46 | 44 | 42 | 34 | 21 | 31 | 41 |
Max speed | ||||||||||||
LwA to inlet | dBA | 67 | 38 | 49 | 63 | 63 | 60 | 57 | 50 | 38 | 47 | 57 |
LwA to outlet | dBA | 66 | 38 | 48 | 61 | 62 | 59 | 56 | 48 | 37 | 46 | 56 |
LwA to environment | dBA | 63 | 34 | 45 | 58 | 58 | 56 | 53 | 46 | 35 | 42 | 52 |
Designation key
Designation key
Series | Air duct diameter | Options |
VENTS TT | 100; 125; 150; 160 | S: high-powered motor; Т: adjustable timer from 2 to 30 minutes; U: speed controller with an electronic thermostat and a temperature sensor integrated inside an air duct. Temperature-based operation logic; Un: speed controller with an electronic thermostat and a temperature sensor fixed on a 4 m cable. Temperature-based operation logic; U1: speed controller with an electronic thermostat and a temperature sensor integrated inside an air duct. Timer-based operation logic; U1n: speed controller with an electronic thermostat and a temperature sensor fixed on a 4 m cable. Timer-based operation logic; U2n: speed controller with an electronic thermostat and a temperature sensor fixed on a 4 m cable. Temperature-based switching on/off; R1: power cord with mains plug; V: threeposition speed switch; P: integrated smooth speed controller. |