VENTS TwinFresh Comfo RA1-85 V.3
- Description
- Characteristics
- Downloads
- Dimensions
- Dimensions
- Ecodesign
- Accessories
TWINFRESH COMFO RA1-50 V.3 | TWINFRESH COMFO RA1-85 V.3 |
Power from 4.5 W | Power from 4.74 W |
Air flow up to 50 m3/h | Air flow up to 85 m3/h |
Sound pressure level from 13 dBA | Sound pressure level from 19 dBA |
UNIVERSAL | EFFICIENT | USER-FRIENDLY | ||||||||||||||||||||||||
Many units can be connected to one network. | The ventilator can operate in a passive supply mode: the air shutters are open providing a natural air flow. | The design of the unit allows easy maintenance of the ventilator. | ||||||||||||||||||||||||
The humidity threshold in the room can be controlled by choosing one of three modes on the remote control. | Night mode The ventilator switches to the first speed in the dark time of the day. |
Easy mounting of the mounting plate by means of magnets. | ||||||||||||||||||||||||
EASY CONTROL | ||||||||||||||||||||||||||
The TwinFresh Comfo series ventilators are equipped with a remote control. |
Operation modes: - Night mode The integrated light sensor sends a signal to switch the ventilator to low speed mode. - Speed switching - Passive air supply In this mode the shutters are open, but the fan does not operate. - Air supply In this mode all ventilators will operate in supply mode irrespective of the maximum air supply setting. - Ventilation All the ventilators in the network operate in permanent air extract or air supply mode. To ensure balanced ventilation at the stage of installation it is advisable to set one half of the ventilators to air supply mode and the other part of the ventilators to air extract mode. - Ventilation with heat recovery - Humidity control mode selection |
|||||||||||||||||||||||||
|
||||||||||||||||||||||||||
ADVANTAGES | ||||||||||||||||||||||||||
|
||||||||||||||||||||||||||
OPERATION IN A NETWORK | ||||||||||||||||||||||||||
|
||||||||||||||||||||||||||
HOW IS IT DESIGNED? | ||||||||||||||||||||||||||
Parameter |
TwinFresh Comfo RA1-85 V.3 1 Speed |
TwinFresh Comfo RA1-85 V.3 2 Speed |
TwinFresh Comfo RA1-85 V.3 3 Speed |
Measurement unit |
---|---|---|---|---|
Speed | 1 | 2 | 3 | - |
Voltage | 100-240 | 100-240 | 100-240 | V |
Frequency | 50/60 | 50/60 | 50/60 | Hz |
Power | 4.74 | 6.56 | 9.65 | W |
Current | 0.034 | 0.05 | 0.071 | A |
SFP | 0.59 | 0.8 | 0.82 | W/l/s |
Air flow in ventilation mode | 36 | 59 | 85 | m³/h |
Air flow in ventilation mode | 10 | 16 | 24 | l/s |
Air flow in energy recovery mode | 18 | 30 | 43 | m³/h |
Air flow in energy recovery mode | 5 | 8 | 12 | l/s |
Shutters | automatic | automatic | automatic | - |
SEC Class | A | A | A | - |
Filter | G3 (G4, F7 optional) | G3 (G4, F7 optional) | G3 (G4, F7 optional) | - |
Transported air temperature | -20*...+40 | -20*...+40 | -20*...+40 | °С |
Sound pressure level at 1 m distance | 29 | 35 | 44 | dBA (sone) |
Sound pressure level at 3 m distance | 19 | 25 | 34 | dBА |
Outdoor sound pressure attenuation according to DIN EN 20140 | 40 | 40 | 40 | dBА |
Heat recovery efficiency according to DIBt LÜ-A 20 | ≤ 90 | ≤ 90 | ≤ 90 | % |
IP Code | IP 24 | IP 24 | IP 24 | - |
Functions | Filter replacement indication, Timer, Humidity sensor | Filter replacement indication, Timer, Humidity sensor | Filter replacement indication, Timer, Humidity sensor | - |
Remote control panel | - | - | - | - |
Duct | 150 | 150 | 150 | - |
* | -30 °C when the EH-13 hood is applied | -30 °C when the EH-13 hood is applied | -30 °C when the EH-13 hood is applied | - |
Parameter | Value | Measurement unit |
---|
TWINFRESH Comfo RA1-85 V.3 | TWINFRESH Comfo RA1-85-2 V.3 with a hood for thin walls |
|
|
Name | Description | ||||||||
EH-14 white 160 | Plastic hood.
|
||||||||
EH-14 chrome 160 | Grey plastic outer hood with a brushed stainless steel cover | ||||||||
EH-17 white 160 | Plastic hood.
|
||||||||
EH-2 grey 160 | Grey painted stainless steel outer hood for thin walls | ||||||||
EH-2 chrome 160 | Polished stainless steel hood for thin walls | ||||||||
EH-13 white 160 | White painted aluminium outer hood for cold climate | ||||||||
EH-13 chrome 160 | Stainless steel ventilation hood for cold climate | ||||||||
MVVM 162 05 | Hood for mounting from inside | ||||||||
MVMO 150 bV1s An | Round metal grille | ||||||||
MVM 152 bVs N | Round stainless steel hood | ||||||||
NP 60x204-0021 | Kit for angular mounting with white colour grille | ||||||||
NP 60x204-0082 | Kit for angular mounting with stainless steel outer grille | ||||||||
3805 | Round telescopic air duct 300-500 mm | ||||||||
3810 | Round telescopic air duct 500-1000 mm | ||||||||
TwinFresh R-50 pre-installation kit | Kit for pre-installation | ||||||||
TwinFresh Comfo RA1-50 V.3 completion kit | Completion kit (for the TwinFresh Comfo RA1-50 V.3 model) | ||||||||
RC TwinFresh Comfo R-50 | Remote control | ||||||||
SF TwinFresh R50 G3 | G3 filter kit (2 pcs.) | ||||||||
SFC 150x50 F7 | F7 filter | ||||||||
SFC 150x50 G4 | G4 filter |