Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use

VENTS TwinFresh Easy RL7-50-17


Single-room heat regeneration unit. Air capacity up to 50 m³/h

  • Description
  • Characteristics
  • Downloads
  • Dimensions
  • Dimensions
  • Ecodesign
  • Accessories
  • Video
Description
Description
Efficient, reliable and energy saving ventilators 24/7:

Provide fresh air supply Prevent excessive indoor humidity and mould build-up
Extract stale air from the room Reduce heating and air conditioning costs
Consume little energy Attenuate indoor noise
Maintain heat regeneration and indoor humidity balance Clean air of dust and insects
APPLICATION  
  • The ventilators are designed to ensure continuous mechanical air exchange in flats, cottages, hotels, cafés and other domestic and public premises.
  • The ventilators are equipped with a regenerator that enables supply of fresh filtered air heated by means of extract air heat regeneration.
  • The ventilators are designed for through-the-wall mounting and are rated for continuous operation.
  • Transported air must not contain any flammable or explosive mixtures, evaporation of chemicals, sticky substances, fibrous materials, coarse dust, soot and oil particles or environments favourable for the formation of hazardous substances (toxic substances, dust, pathogenic germs).
VENTILATOR DESIGN VENTS TwinFresh Easy RL7-50-17  
VENTILATOR DESIGN VENTS TwinFresh Easy-D RL7-50-17  
CERAMIC ENERGY REGENERATOR  
  • The high-tech ceramic energy accumulator with regeneration efficiency up to 97 % ensures extract air heat recovery for warming of supply air flow.
  • Due to the cellular structure the unique regenerator has a large air contact surface and high heat-conducting and heat-accumulating properties.
  • The ceramic regenerator is treated with an antibacterial composition which prevents bacteria growth inside of the energy regenerator.
  • The antibacterial properties last for 10 years.
AIR FILTERS  
  • The two integrated air filters with total filtration rate G3 provide supply and extract air filtration.
  • The filters prevent ingress of dust and insects into the supply air and contamination of the ventilator parts. The filters also have antibacterial treatment.
  • The filter cleaning is done with a vacuum cleaner or water flushing. The antibacterial solution is not removed.
  • F8 filter is available as a specially ordered accessory, but when installed, it reduces the air flow down to 40 m3/h.
REVERSIBLE DC-FAN  
  • The reversible axial fan with a DC motor and power supply voltage of 12 V serves for air supply and exhaust.
  • Due to the applied DC technology the fan is featured with low power consumption.
  • The fan motor has integrated thermal overheating protection and ball bearings for long service life.
CONTROL AND OPERATION MODES  
  • The ventilator is operated with the wall-mounted control panel or the remote control for your convenience.
  OPERATION MODES:
  • Ventilation mode. The ventilator runs in the air extract or air supply mode with a set speed. In case of synchronous operation of two connected ventilators one unit operates in the supply mode and the other one in the extract mode.
  • Regeneration mode. The ventilator runs in two cycles, 70 seconds each, to provide heat and moisture regeneration.
  • interval 1. The warm polluted air is extracted from the room and flows through the ceramic regenerator, which gradually absorbs heat and moisture. In 70 seconds after warming is started the ventilator switches to the air supply mode.
  • interval 2. The fresh and cold outdoor air flows through the heat regenerator and absorbs the accumulated moisture and heat so that the supply air flow has the room temperature. In 70 seconds, when the energy regenerator gets cold, the ventilator switches to the air extract mode. The cycle starts from the beginning. If two ventilators are installed, they run in opposite phases. While one ventilator supplies fresh air, the second one extracts air from the room.
FUNCTIONING OF THE VENTILATORS  

The reversible operation of the ventilator enables energy regeneration and consists of two cycles:

CYCLE I
  • The polluted warm air is extracted from the room and while passing the ceramic energy regenerator, it transfers the heat and moisture to it. In 70 seconds, as the energy regenerator gets warmed, the ventilator automatically switches to the supply mode. 
CYCLE II
  • The fresh, but cold outdoor air flows through the heat regenerator and absorbs the accumulated moisture and heat so that the supply air flow has the room temperature. In 70 seconds, when the energy regenerator gets cold, the ventilator switches to the air extract mode. The cycle starts from the beginning. The changeover between the supply and extract modes takes place each 70 seconds.
VENTILATION ARRANGEMENT EXAMPLE  
  • The ventilation system based on the TwinFresh ventilators provides for one ventilator in each room.
  • To ensure balanced ventilation, it is advisable to use a paired number of ventilators and connect those into a single network.
  • Some ventilators must be set to operate in the supply mode and the other ventilators must be set to operate in the extract mode.
  • For bigger rooms two and more ventilators are recommended.
  • TwinFresh may be used as an individual unit.  In this case the ventilation mode must be selected individually for each room.
  • Air moves between the rooms through the door openings and corridors and this way the required air circulation in the house is arranged.
  • The ventilation system with energy regeneration based on the TwinFresh ventilators significantly reduces heating and air conditioning costs.
  • iFan WiFi fans are recommended for very efficient extract ventilation in the kitchen and bathroom.
  • Polluted air is extracted automatically in case of actuation of the motion or humidity sensors.
INSTALLATION EXAMPLE  

Mounting into a wall with a standard thickness
using the EH-14 outer grille

Flush mounting using the angular
mounting kit NP

Mounting into a thin wall using the EH-2
outer hood

Characteristics
Characteristics
Parameter TwinFresh Easy RL7-50-17
1 speed
TwinFresh Easy RL7-50-17
2 speed
TwinFresh Easy RL7-50-17
3 speed
Measurement unit
Speed 1 2 3 -
Voltage 100-240 100-240 100-240 V
Power 1 2.1 4.3 W
Frequency 50/60 50/60 50/60 Hz
Current 0.017 0.025 0.041 A
SFP 0.48 0.50 0.62 W/l/s
F8 filter filtration rate PM2.5 99 99 99 %
Air flow with F8 filter applied 40 40 40 m³/h
Regeneration efficiency ≤ 92 ≤ 92 ≤ 92 %
Air flow in ventilation mode 15 30 50 m³/h
Air flow in ventilation mode 4 8 14 l/s
Air flow in energy recovery mode 8 15 25 m³/h
Air flow in energy recovery mode 2 4 7 l/s
Shutters manual manual manual -
Filter G3 (F8 optionally) G3 (F8 optionally) G3 (F8 optionally) -
SEC Class A A A -
Transported air temperature -15 ... +40 -15 ... +40 -15 ... +40 °С
Sound pressure level at 1 m distance 21 27 29 dBА
Sound pressure level at 3 m distance 12 18 20 dBА
Outdoor sound pressure attenuation according to DIN EN 20140 41 41 41 dBА
The classification of the indoor/outdoor air tightness, according to EN 13141-8 D1 D1 D1 -
The classification of the airflow sensitivity to pressure variations, according to EN 13141-8 [%] S3 S3 S3 -
Functions Filter replacement indication, Timer Filter replacement indication, Timer Filter replacement indication, Timer -
Remote control panel LCD LCD LCD -
Duct 160 160 160 -
Type supply and exhaust supply and exhaust supply and exhaust -
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
Сatalogue "Single-room energy recovery units TwinFresh" (pdf 26.52Mb)
"VENTS TwinFresh Easy RL7-50-17" product description 08-2018 (pdf 7.24Mb)
Download image "VENTS TwinFresh Easy RL7-50-17" for your website (png 240.95Kb)
Download high quality image "VENTS TwinFresh Easy RL7-50-17" (psd 1.48Mb)
"Outer ventilation hood with frost protection EH-13" installation instruction 05-2018 (V113-10EN-01) (pdf 1.21Mb)
"VENTS TwinFresh Easy-D RL7-50-17" product description 11-2018 (pdf 7.23Mb)
Download image "VENTS TwinFresh Easy-D RL7-50-17" for your website (png 248.44Kb)
Download high quality image "VENTS TwinFresh Easy-D RL7-50-17" (psd 1.48Mb)
"VENTS TwinFresh Easy" user's manual 06-2022 (V127-1EN-01) (pdf 3.29Mb)
Dimensions
Characteristics
VENTS TwinFresh Easy RL7-50-17
Parameter Value Measurement unit
Dimensions
Dimensions

Ecodesign
Ecodesign
Specific energy consumption (SEC), kWh/(m2.a) Cold Average

Warm

-76 А+ -37 А -14 Е
Type of ventilation unit Bidirectional
Type of drive installed Three-speed
Type of heat recovery system Regenerative
Thermal efficiency of heat recovery [%] 76
Maximum air flow rate [m3/h] 25
Power [W] 4.3
Sound power level [dBA] 38
Reference air flow rate [m3/s] 0.004
Reference pressure difference [Pa] 0
Specific power input (SPI) [W/(m3/h)] 0.14
Control typology Clock control
Maximum internal leakage rates [%] 2.7
Maximum external leakage rates [%] 0
Mixing rate of bidirectional units [%] 1
The classification of the airflow sensitivity to pressure variations, according to EN 13141-8 [%] 26
The classification of the indoor/outdoor air tightness, according to EN 13141-8 [m3/h] 2.4
Internet address http://ventilation-system.com/
The annual electricity consumption (AEC) [kWh electricity/a] Cold Average Warm
179 179 179
The annual heating saved (AHS) [kWh primary energy/a] Cold Average Warm
8024 4140 1855
Specific energy consumption (SEC), kWh/(m2.a) Cold Average

Warm

-76.2 А+ -37 А -15 Е
Type of ventilation unit Bidirectional
Type of drive installed Three-speed
Type of heat recovery system Regenerative
Thermal efficiency of heat recovery [%] 76
Maximum air flow rate [m3/h] 50
Power [W] 7.6
Sound power level [dBA] 38
Reference air flow rate [m3/s] 0.008
Reference pressure difference [Pa] 0
Specific power input (SPI) [W/(m3/h)] 0.127
Control typology Clock control
Maximum internal leakage rates [%] 2.7
Maximum external leakage rates [%] 0
Mixing rate of bidirectional units [%] 1
The classification of the airflow sensitivity to pressure variations, according to EN 13141-8 [%] 26
The classification of the indoor/outdoor air tightness, according to EN 13141-8 [m3/h] 2.4
Internet address http://ventilation-system.com/
The annual electricity consumption (AEC) [kWh electricity/a] Cold Average Warm
162 162 162
The annual heating saved (AHS) [kWh primary energy/a] Cold Average Warm
8024 4140 1855
Accessories
Accessories
SF TwinFresh Easy R-50 F8
F8 Filter  

 SF TwinFresh Easy R-50 G3
G3 filter set (2 pcs.)

 MVM 152 bVsN
Round stainless steel outer hood 
MVMO 150 bV1s An
Round metal grille
       
 RK TwinFresh Easy RL-50
Remote control
KV TwinFresh Easy RL-50
LCD control panel 

EH-2 grey 160
Grey painted stainless steel outer hood for thin walls

EH-2 chrome 160
Brushed stainless steel outer hood for thin walls
       
NP white 160
Angular mounting kit
 NP chrome 160
Angular mounting kit  
Duct 160-500
Air duct 500 mm
 Duct 160-700
Air duct 700 mm
       

MVVM 162 05
Outer hood for mounting from indoor 

EH-14 white 160
White plastic outer hood
EH-14 chrome 160
Grey plastic outer hood with a brushed stainless steel cover 
 S3 TwinFresh
Cartridge for cold climate 
     
SF TwinFresh Easy R-50 F8
F8 Filter (complete with a plastic cup) 
 EH-13 white 160
White painted aluminium outer hood for cold climate
 EH-13 chrome 160
Brushed stainless steel outer hood for cold climate
EH-14 brown 160
Brown plastic outer hood 
   
 EH-14 black 160
Black plastic outer hood
 EH-14 grey 160
Grey plastic outer hood
EH-14 beige 160
Beige plastic outer hood
EH-14 terracotta 160
Terracotta plastic outer hood
 
EH-17 white 160
White plastic outer hood
 EH-17 brown 160
Brown plastic outer hood
EH-17 black 160
Black plastic outer hood
EH-17 grey 160
Grey plastic outer hood
     
EH-17 beige 160
Beige plastic outer hood
EH-17 terracotta 160
Terracotta plastic outer hood
   
Video
Video

Share your opinion

Questionnaire
Where have you learned about us?