VENTS VC 100 Q*
- Description
- Characteristics
- Capacity diagram
- Downloads
- Dimensions
- Additional diagrams
- Legend
Description
Description
APPLICATIONS | |
|
|
DESIGN | |
|
|
MOTOR | |
|
|
SPEED CONTROL | |
|
|
MOUNTING | |
|
|
Characteristics
Characteristics
Parameter |
VC 100 Q* |
Measurement unit |
---|---|---|
Low-powered motor | yes | - |
Highpowered motor | no | - |
Phase | 1 | ˜ |
Voltage | 230 | V |
Frequency | 50 | Hz |
Sound pressure level at 3 m distance | 36 | dBА |
Power consumption | 60 | W |
Current | 0.37 | A |
RPM | 2620 | min-1 |
Max. transported air temperature | -25...+55 | °С |
Protection rating | IP X4 | - |
Design | centrifugal | - |
Weight | 3.1 | kg |
Maximum air capacity | 210 | m³/h |
Duct diameter | 100 | mm |
Casing material | polymer coated steel | - |
Outdoor mounting | yes | - |
SEC Class | C | - |
Duct | for round air ducts | - |
Type | exhaust, supply | - |
Mounting | outdoor mounting, wall mounting, Inline | - |
Capacity diagram
Capacity diagram
- Selection method:
- Air flow:
- Pressure:
Operating point
- Air flow: --
- Pressure: ---
Files archieve
Downloads
Select document type
Dimensions
Characteristics
Parameter | Value | Measurement unit |
---|---|---|
∅D | 98 | mm |
∅d | 6.1 | mm |
ØD1 | 249 | mm |
H | 310 | mm |
H1 | 295 | mm |
L | 115 | mm |
Additional diagrams
Additional diagrams
Sound-power level | Octave-frequency band [Hz] | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Hz | General | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 | |||||||||||
LwA to inlet | dBA | 62 | 52 | 60 | 56 | 66 | 48 | 48 | 41 | 28 | ||||||||||
LwA to outlet | dBA | 67 | 49 | 57 | 58 | 68 | 54 | 52 | 45 | 30 | ||||||||||
LwA to environment | dBA | 55 | 19 | 16 | 23 | 40 | 39 | 42 | 30 | 19 |
* Compliant to the ErP-regulation (EC) 327/2011, the power consumption at optimum efficiency is < 125W.
Legend
Legend
Fan series | Flange diameter, mm | Modification | Mounting options | Options |
---|---|---|---|---|
VENTS VC S – high-powered motor |
100; 125; 150; 160; 200; 250; 315 | V - exhaust; P - supply |
N - surface wall mounting; К - through-the-wall duct mounting |
Q - low-powered motor |
ErP data | |
Overall efficiency | η,[%] |
Measurement category | MC |
Efficiency category | EC |
Efficiency grade | N |
Variable speed drive | VSD |
Power | [kW] |
Current | [A] |
Air flow | [m3/h] |
Static pressure | [Pa] |
Speed | [n/min-1] |
Specific ratio | SR |
Accessories