Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use

VENTS 125 VKO1

  • Description
  • Characteristics
  • Downloads
  • Dimensions
  • Wiring plan
  • Legend
  • Example of installation
  • BIM
Description
Description
APPLICATIONS  
  • Continuous or periodic exhaust ventilation of bathroom, showers, kitchens and other utility spaces.
  • Exhaust or supply ventilation depending on the fan mounting type in the system.
  • Designed for PVC ducting systems or flexible ducts.
  • Low to medium air flow motion for short distances at low air resistance.
  • Compatible with 100, 125 and 150 mm air ducts.
DESIGN  
  • The casing and the impeller are made of high-quality durable ABS plastic, UV resistant.
  • The intellectual impeller design makes the fan efficiency high and the service life long.
  • Protection rating IP X4.
MOTOR  
  • Reliable and low-watt electric motor.
  • Designed for continuous operation and requires no maintenance.
  • Equipped with overheating protection.
CONTROL  
Manual: Automatic:
  • The fan is controlled by a room light switch. It is not included in the delivery package.
  • Speed control is possible through a thyristor speed controller (see Electrical Accessories). Several fans may connected to the same controller. Speed controllers can not be connected to the fans with TTHTPVTVTH modification.
  • By the electronic control unit BU-1-60 (see Electrical Accessories). The control unit is supplied separately.
  • By the timer T (the built-in run-out timer enables the fan operation within 2 to 30 minutes after the fan switching off).
MOUNTING FEATURES  
  • The fan is mounted into a matching duct size. Fastening with clamps in case of flexible duct connection.
  • The mounting bracket enables fan installation on both horizontal and vertical flat surfaces (VKO1k model).
  • Two fans can be installed in series for higher performance.
  • For 12 V low-voltage motor fan connection to 220 V / 50 Hz power mains use the step-down transformer TRF 220/12-25 that is available upon separate order.
MOUNTING EXAMPLES  
 
   
    VENTS VKO1k fan cottage ventilation example   VENTS VKO1 fan flat ventilation example    
Characteristics
Characteristics
Parameter VENTS 125 VKO1
Measurement unit
Voltage 220-240 V
Frequency 50/60 Hz
Power consumption 16 W
Air capacity 190 m³/h
Current 0.1 A
RPM 2400 min-1
Sound pressure level at 3 m 38 dBА
Weight 0.43 kg
Spigot size 125 mm
Engine Type 220-240V / 50-60Hz -
Design axial -
Duct diameter 125 mm
IP Code IP X4 -
Type supply and exhaust -
Mounting Inline -
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
Certificate GS "VKO1" (pdf 181.37Kb)
"VENTS VKO1 and VKO1k" product description 09-2015 (pdf 3.94Mb)
Declaration of сonformity "PF,PF1,VKO,VKO1 K,+turbo" (pdf 1.69Mb)
Declaration of сonformity "PF,VKO,VKO1 K,+turbo,+press" (pdf 1.59Mb)
Download high quality image "VENTS VKO1 and VKO1k" (psd 1.61Mb)
Download image "VENTS VKO1" for your website (png 463.97Kb)
Download image "VENTS VKO1k" for your website (png 399.55Kb)
Certificate LVD "VKO1" (pdf 161.17Kb)
“Axial fans VENTS VKO, VKO1” user's manual 07-2020 (V214EN-01) (pdf 1.02Mb)
"VENTS domestic fans" user's manual 07-2023 (V01EN_16-01) (pdf 3.9Mb)
Download image "VENTS VKO1 and VKO1k" for your website (png 332.85Kb)
Download high quality image "VENTS VKO1" (psd 2.24Mb)
Download high quality image "VENTS VKO1k" (psd 1.93Mb)
Dimensions
Characteristics
VENTS 125 VKO1
Parameter Value Measurement unit
Ø D 125 mm
∅d 59 mm
L 90 mm
L1 28 mm
Wiring plan
Wiring plan
Wiring diagram for the fans equipped with a built-in switch Wiring diagram for the fans without built-in switch
Wiring diagram for the fans equipped with a timer / timer, humidity sensor and a built-in switch Wiring diagram for the fans equipped with a timer / timer with a humidity sensor without built-in switch
Wiring diagram for the fans with a light lamp. Separate activation of the fan and the built-in lamp. Wiring diagram for the fans with a light lamp. Parallel activation of the fan and the built-in lamp.
Wiring diagram for the fans with an light lamp and grounding. Separate activation of the fan and the built-in lamp. Wiring diagram for the fans with a light lamp and grounding. Parallel switching of the fan and the built-in lamp.
Wiring diagram for the fans with grounding  
 

* - only for fans designed for 12 V rated voltage (specified on the fan casing and packing).
S, S1, S2 - external switches.

Operating logic of the fans with optional equipment
  • The fan equipped with a timer is activated by the control voltage supplied to LT input. After the control voltage is disconnected the fan continues operating within the time period within 2 to 30 minutes according to the timer settings. The turn-off delay time is adjusted by turning the respective potentiometer T control knob clockwise to increase and counter-clockwise to reduce it.
  • The fan equipped with a timer and humidity sensor is activated by the control voltage supplied to LT input or in case of exceeding the preset humidity threshold value adjustable from ~60% to ~90%. After the control voltage is disconnected or as the humidity level H drops below the set threshold the fan continues operating within the time period within 2 to 30 minutes according to the timer settings.  The turn-off delay time and the threshold humidity level are adjusted by turning the control knob of the respective potentiometer T for timer and H for humidity sensor clockwise to increase and counter-clockwise to reduce the set value. To set the maximum humidity level (90%) set the potentiometer control knob for H max position.
  • The fan equipped with a timer and motion sensor is activated in case of the moving detection at the distance from 1 m to 4 m with 100° detection angle. After motion is off the fan continues operating within the time period within 2 to 30 minutes according to the timer settings. The turn-off delay time is adjusted by turning the respective potentiometer T control knob clockwise to increase and counter-clockwise to reduce it.
  • Wiring diagram for connection of the light lamp to the fan timer operated by the common switch is shown on diagram 4. Upon the light lamp disconnection the fan continues operating according to the timer setting within the set time period.
Legend
Legend
Picture symbol   Designation   Modification description
    VKO1k   Fan with a fixing bracket for flat surface mounting.
  VKO1 L   The motor is equipped with ball bearings for long service life (appr. 40  thousand hours) and fan mounting at any angle. The bearings are maintenance-free and contain enough grease for the entire operating period.
  VKO1 turbo   High-powered motor.
  VKO1 press   5-blade low-noise impeller with improved aerodynamics for higher fan capacity.
  VKO1 12   Modification with low-voltage motor. 12 V AC power supply.
  VKO1 T   Equipped with a regulated timer with the operating time from 2 to 30 minutes.
Example of installation
Example of installation

BIM
BIM

Accessories
Share your opinion

Questionnaire
Is our site helpful for your business development?