Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use

VENTS 150 Silenta-M

  • Description
  • Characteristics
  • Downloads
  • Modifications
  • Dimensions
  • Designation key
  • Video
Description
Description
APPLICATION
  • Continuous or periodic exhaust ventilation of bathroom, showers, kitchens and other utility spaces.
  • Ventilation of premises with high noise level limitations.
  • Ventilation shaft mounting or duct connection.
  • Compatible with Ø 100, 125 and 150 mm air ducts.
DESIGN
  • Modern design and aesthetic look.
  • The casing and the impeller are made of high-quality durable ABS plastic, UV resistant.
  • The intellectual impeller design makes the fan efficiency high and the service life long.
  • The fan and motor are specially designed for silent operation.
  • Protection rating IP34.
MOTOR
  • Reliable motor with the minimum power consumption 7 W (for 100 mm diameter).
  • Designed for continuous operation and requires no maintenance.
  • Equipped with overheating protection.
CONTROL

Manual:

  • The fan is controlled by a room light switch. It is not included in the delivery package.
  • The fan is controlled by the built-in pull cord switch V. Not applied in case of ceiling mounting.
  • Speed control is possible through a thyristor speed controller. Several fans may connected to the same controller. Speed controllers can not be connected to the fans with T, TH, TP, VT, VTH modification.

 

Automatic:

  • By the electronic control unit BU-1-60. The control unit is supplied separately.
  • By the timer T (the built-in turn-off delay timer enables the fan operation within 2 to 30 minutes after the fan switching off).
  • By the humidity sensor and timer TH (if the humidity level in the room exceeds the sensor threshold adjustable value within 60-90 % the fan switches automatically on and operates until the humidity level drops to the standard level, after that the fan continues operating within the time period according to the timer setting, then shuts down).
  • By the motion sensor and the timer TP (in case of motion detection the fan switches automatically on and operates within the set time period from 2 to 30 minutes. The motion sensitivity area is up to 4 meters and the maximum detection angle is 100°).
MOUNTING FEATURES
  • The fan is mounted directly into the ventilation shaft.
  • Fixed to wall by self-tapping screws.
  • Suitable for ceiling mounting.
  • Flexible duct application is recommended in case of remote location of the ventilation shaft. The air duct is connected to the fan exhaust flange through a clamp.
MOUNTING EXAMPLE
Characteristics
Characteristics
Parameter VENTS 150 Silenta-M
VENTS 150 Silenta-M L
VENTS 150 Silenta-MT
VENTS 150 Silenta-MTH
VENTS 150 Silenta-MTP
VENTS 150 Silenta-MVT K
VENTS 150 Silenta-MT L
Measurement unit
Voltage 220-240 220-240 220-240 220-240 220-240 220-240 220-240 V
Frequency 50 50 50 50 50 50 50 Hz
Power consumption 20 20 20 20 20 20 20 W
Air capacity 242 242 242 242 242 242 242 m³/h
Current 0.14 0.14 0.14 0.14 0.14 0.14 0.14 A
Sound pressure level at 3 m 33 33 33 33 33 33 33 dBА
Weight 0.82 0.82 0.82 0.82 0.82 0.82 0.82 kg
Spigot size 150 150 150 150 150 150 150 mm
Engine Type 220-240V / 50Hz 220-240V / 50Hz 220-240V / 50Hz 220-240V / 50Hz 220-240V / 50Hz 220-240V / 50Hz 220-240V / 50Hz -
Design axial axial axial axial axial axial axial -
Duct diameter 150 150 150 150 150 150 150 mm
IP Code IP 34 IP 34 IP 34 IP 34 IP 34 IP 34 IP 34 -
Type exhaust exhaust exhaust exhaust exhaust exhaust exhaust -
Mounting wall mounting, ceiling mounting wall mounting, ceiling mounting wall mounting, ceiling mounting wall mounting, ceiling mounting wall mounting, ceiling mounting wall mounting, ceiling mounting wall mounting, ceiling mounting -
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
"VENTS Silenta-M" product description 02-2020 (pdf 3.57Mb)
Download high quality image "VENTS Silenta-M" (psd 2.49Mb)
Download image "Silenta-M" for your website (png 537.74Kb)
"VENTS domestic fans" user's manual 07-2023 (V01EN_16-01) (pdf 3.9Mb)
“VENTS Silenta-M, Silenta-S” user's manual 2011 (V01-(SILENTA M-S)-03) (pdf 4.57Mb)
"VENTS Silenta-M, Silenta-S" leaflet 09-2015 (pdf 407.23Kb)
Modifications
Modification name Backdraft damper Humidity sensor Timer Motion sensor Pull-cord switch Ball bearing motor
VENTS 150 Silenta-M - - - - - -
VENTS 150 Silenta-M L - - - - -
VENTS 150 Silenta-MT - - - - -
VENTS 150 Silenta-MTH - - - -
VENTS 150 Silenta-MTP - - - -
VENTS 150 Silenta-MVT K - - -
VENTS 150 Silenta-MT L - - - -
+
+
+
+
+
+
+
Dimensions
Characteristics
VENTS 150 Silenta-M
Parameter Value Measurement unit
Ø D 150 mm
B 206 mm
H 182 mm
L 106 mm
L1 26 mm
Designation key
Designation key
PICTURE SYMBOL DESIGNATION MODIFICATION DESCRIPTION
Silenta-M K Fan is equipped with a backdraft damper for back flow preventing.
Silenta-M L The motor is equipped with ball bearings for long service life (appr. 40 thousand hours) and fan mounting at any angle. The bearings are maintenance-free and contain enough grease for the entire operating period.
Silenta-MT Equipped with a regulated timer with the operating time from 2 to 30 minutes.
Silenta-MTH Equipped with a timer with the operating time from 2 to 30 minutes and a humidity sensor with the threshold value from 60 to 90 %.
Silenta-MV Equipped with a pull cord switch.
Silenta-MVT Equipped with a pull cord switch and a regulated timer with the operating time adjustable from 2 to 30 minutes.
Silenta-MVTH Equipped with a pull cord switch, regulated timer with the operating time adjustable from 2 to 30 minutes and a humidity sensor with the operating threshold range from 60 to 90 %.
Silenta-MTP Equipped with a regulated timer and a motion sensor with the sensitivity area from 1 to 4 m and the detection angle up to 100°.
Video
Video

Accessories Similar products
Share your opinion

Questionnaire
Basic parameter for domestic fan selection