Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use

VENTS MICRA 100 WiFi


Air flow up to 100 m³/h.

3D model
Gallery
  • Description
  • Characteristics
  • Capacity diagram
  • Downloads
  • Dimensions
  • Dimensions
  • Ecodesign
  • Accessories
  • Video
Description
Description
FEATURES  
  • Efficient solution for supply and exhaust ventilation of separate spaces.
  • Electric pre-heater or re-heater modification available for cold climate conditions.
  • Heat exchanger with an enthalpy membrane modification available for humid and hot climate conditions.
  • Low-energy ЕС fans.
  • Supply air purification ensured with two built-in G4 and F8 filters (optional H13, F8 Carbon).
  • Excellent noise control (25-38 dBA).
  • Upgradeable with an exhaust duct to provide air extraction from the bathroom.
  • Easy installation.
  • Compact size.
  • Modern design.
  • Control with the mobile application Android / IOS.
DESIGN  
CASING FANS
  • Polymer coated metal casing decorated with an acrylic front panel. Thanks to the modern design the unit can seamlessly blend with most interior design. Heat and sound insulation is provided with 10 mm cellular synthetic rubber layer. The front panel ensures convenient access for filter maintenance and has a lock for extra security. The unit has two ø 100 mm inlet and outlet spigots for fresh air intake and stale air extraction outside. The third ø 100 mm spigot (included) can be additionally fitted to the unit to connect an exhaust air duct from the bathroom.
  • The units feature efficient electronically commutated (ЕС) motors with external rotor and impellers with forward curved blades. The state-of-the-art motor design offers the very best energy efficiency performance. EC motors are distinguished with high performance and totally controllable speed range. In addition to that the efficiency of electronically commutated motors reaches very impressive levels of up to 90 %.
AIR DAMPERS NE MICRA 100 HEATER FOR CONDENSATE FREEZING PROTECTION (OPTIONAL)
  • The unit is equipped with supply and exhaust air dampers, which activate automatically to prevent drafts while the unit is off.
  • Operation in a cold climate may result in condensate freezing in the exhaust air duct and the external hood. Therefore, it is recommended to install the NE MICRA 100 heater (purchased separately) to prevent icing.
AIR FILTRATION PRE-HEATING
  • G4 and F8 panel filters provide supply air filtration (PM2.5 > 75 %). To meet more stringent air purity requirements a F8 filter can be replaced with an H13 (PM2.5 > 95 %) or F8 Carbon (purchased separately).
  • G4 panel filter provides extract air filtration.
  • MICRA 100 E WiFi, MICRA 100 E2 WiFi units are equipped with an electric pre-heater for freeze protection of the heat exchanger.
RE-HEATING
  • MICRA 100 E1 WiFi, MICRA 100 E2 WiFi units feature an electric re-heater to raise the supply air temperature as necessary.
HEAT EXCHANGER  
  • MICRA 100 WiFi units are equipped with a counter-flow heat exchanger with a polystyrene core.
  • In the cold season the extract air heat is captured and transferred to the supply air stream, which reduces the ventilation-generated heat losses. However, this process may be associated with condensation, which is collected in a special drain pan and evacuated outside via the exhaust air duct.
  • In the warm season the ambient air heat is transferred to the exhaust air stream. This allows for a considerable reduction of the supply air temperature, which reduces operation load for the air conditioners.
  • MICRA 100 ERV WiFi units are equipped with a counter-flow heat exchanger with an enthalpy membrane.
  • In the cold season the extract air heat and moisture are transferred to the supply air stream through the enthalpy membrane reducing the heat losses from ventilation.
  • Consequently, the heat and moisture of the ambient air is transferred to the exhaust air stream through the enthalpy membrane in the warm season. This allows for a considerable reduction of the supply air temperature and humidity, which reduces operation load for the air conditioners.
FUNCTIONING CONTROL PANEL
CONTROL  
  • The unit is equipped with a control panel
  • The remote control is supplied as standard
  • Wi-Fi communication
  • Controlled by Android or iOS smartphone or tablet

1. Turning unit on/off
2. Speed selection
3. Increasing temperature set point for the re-heater (available for the models with a re-heater)
4. Turning re-heater on/off (available for the models with a re-heater)
5. Decreasing temperature set point for the re-heater (available for the models with a re-heater)
6. Turning timer on/off
7. Activation/deactivation of the scheduled operation mode

FUNCTIONS
 

VENTS MICRA app is available
at Google Play Market and App Store

  • Speed changeover
  • Filter replacement indication
  • Alarm indication
  • Speed setting
  • Timer
  • Weekly schedule
FREEZE PROTECTION
  • MICRA 100 (ERV) WiFi features an exhaust air temperature sensor downstream of the heat exchanger, which disables the supply fan to let the warm extract air warm up the heat exchanger. After that the supply fan turns on and the unit reverts to the normal operation mode.
  • Overheating protection for MICRA 100 E WiFi and MICRA 100 E2 WiFi is implemented with a pre-heater.
Following functions are available:  
  MICRA 100 WiFi
MICRA 100 E WiFi
MICRA 100 E1 WiFi
MICRA 100 E2 WiFi
Speed selection + +
Filter replacement indication + +
Alarm indication + +
Speed setup + +
Timer + +
Week scheduler + +
Re-heater enabled/disabled - +
Supply air temperature setup - +
Control with the mobile application VENTS MICRA Android / IOS + +
MOUNTING EXAMPLE  
  • Each space requiring ventilation is equipped with one or several MICRA 100 WiFi units.
  • A single unit is capable to ensure efficient ventilation in spaces with floor area up to 100 m2.
  • MICRA 100 WiFi units can be upgraded with a bathroom exhaust air duct. To enable such a configuration the units can be additionally equipped with the optional ø 100 mm spigot (supplied as standard).
MICRA 100 WiFi deployment in a compact residential space 
MICRA 100 WiFi mounting example in the office
Characteristics
Characteristics
Parameter MICRA 100 WiFi
1 speed
MICRA 100 WiFi
2 speed
MICRA 100 WiFi
3 speed
MICRA 100 WiFi
4 speed
MICRA 100 WiFi
5 speed
Measurement unit
Speed 1 2 3 4 5 -
Phase 1 1 1 1 1 ˜
Maximum unit power without an electric heater 20 23 29 37 53 W
Voltage 110-240 110-240 110-240 110-240 110-240 V
Max. unit current without electric heater 0.4 0.4 0.4 0.4 0.4 A
Electric preheater power - - - - - W
Electric reheater power - - - - - W
Max. unit current with electric heater - - - - - A
Frequency Frequency 50/60 50/60 50/60 50/60 50/60 Hz
Maximum air capacity Maximum air capacity 30 44 60 75 100 m³/h
Air capacity Air capacity 30 44 60 75 100 m³/h
RPM 2200 2200 2200 2200 2200 min-1
Heat recovery efficiency 96 94 92 89 87 %
Sound pressure level at 3 m distance 13 20 27 33 39 dBА
Functions Wi-Fi, Filter replacement indication, Timer, Weekly schedule Wi-Fi, Filter replacement indication, Timer, Weekly schedule Wi-Fi, Filter replacement indication, Timer, Weekly schedule Wi-Fi, Filter replacement indication, Timer, Weekly schedule Wi-Fi, Filter replacement indication, Timer, Weekly schedule -
Casing material polymer coated steel polymer coated steel polymer coated steel polymer coated steel polymer coated steel -
Heating without heating without heating without heating without heating without heating -
Remote control panel Sensor Wi-Fi Sensor Wi-Fi Sensor Wi-Fi Sensor Wi-Fi Sensor Wi-Fi -
Insulation 10 mm 10 mm 10 mm 10 mm 10 mm -
Filter: extract G4 G4 G4 G4 G4 -
Filter: supply G4, F8, * F8 Carbon; H13 G4, F8, * F8 Carbon; H13 G4, F8, * F8 Carbon; H13 G4, F8, * F8 Carbon; H13 G4, F8, * F8 Carbon; H13 -
Weight 31 31 31 31 31 kg
Heat exchanger material polystyrene polystyrene polystyrene polystyrene polystyrene -
Heat exchanger type counter-flow counter-flow counter-flow counter-flow counter-flow -
Duct 100 100 100 100 100 -
Type supply and exhaust supply and exhaust supply and exhaust supply and exhaust supply and exhaust -
SEC Class A A A A A -
Option* -
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
Сatalogue "Single-room air handling units with heat recovery MICRA" (pdf 6.4Mb)
"VENTS MICRA 100 WiFi" product description 05-2020 (pdf 6.41Mb)
Download image "VENTS MICRA 100 WiFi" for your website (png 415.95Kb)
Download high quality image "VENTS MICRA 100 WiFi" (psd 4.5Mb)
"VENTS MICRA 100 WiFi" user's manual 07-2023 (V73-9EN-07) (pdf 3.04Mb)
"VENTS MICRA 100 WiFi" connection guide 12-2019 (V73-9-1EN-01) (pdf 557.38Kb)
"Electric heater NE Micra" user's manual 11-2022 (V73-8EN-03) (pdf 1.8Mb)
Dimensions
Characteristics
Parameter Value Measurement unit
Dimensions
Dimensions

Ecodesign
Ecodesign
Trade mark VENTS
Model MICRA 100 WiFi
Specific energy consumption (SEC), kWh/ (m².a) Cold Average Warm
-79.4 А+ -39.7 А -14.3 Е
Type of ventilation unit Bidirectional
Type of drive installed Variable speed
Type of heat recovery system Recuperative
Thermal efficiency of heat recovery, % 92
Maximum flow rate, m³/h 100
Electric power input, W 53
Sound power level, dB(A) 47
Reference flow rate, m³/s 0.017
Reference pressure difference, Pa N/A
Specific power input (SPI), W/(m³/h) 0.483
Control typology Local demand control
Maximum internal leakage rates, % 0.1
Maximum external leakage rates, % 0.9
Mixing rate of bidirectional units, % 20
Airflow sensitivity at +20 Pa and -20 Pa 0.93
The indoor/outdoor air tightness, m³/h 7
Internet address www.ventilation-system.com
Annual electricity consumption (AEC), kWh electricity/a Cold Average Warm
863 326 281
Annual heating saved (AHS), kWh primary energy/a Cold Average Warm
9230 4718 2133
Accessories
Accessories
Name Picture Description
MK Micra 100 white Mounting kit:
Two plastic Ø 100 mm air ducts 500 mm long;
Outdoor box (white);
Cardboard template
MK Micra 100 chrome Mounting kit:
Two plastic Ø 100 mm air ducts 500 mm long;
Outdoor box made of hairline stainless steel;
Cardboard template
NB Micra 100 white Outdoor box (white)
NB Micra 100 chrome Hairline stainless steel outdoor box
NE Micra 100 Heater to prevent condensate freezing in the drain pipe and the outdoor box
SF 193x158x18 G4 PPI G4 filter
SF 193x158x47 F8 F8 filter
SF 193x158x47 F8 C F8 carbon filter
SF 193x158x47 H13 H13 HEPA filter
HR-S HR-S humidity sensor
CO2-1 СО2 sensor with air quality indication and On/Off button
CO2-2 CO2 sensor
Video
Video

Share your opinion

Questionnaire
Basic parameter for domestic fan selection