VENTS VNV-1A 80
- Description
- Characteristics
- Capacity diagram
- Downloads
- Dimensions
- Additional characteristics
- Dimensions
- Options description
- Video
Description
Description
APPLICATION | |
|
|
DESIGN | |
|
|
MOTOR | |
|
|
MODIFICATIONS AND OPTIONS | |
VNV-1A(E) 80 T— the fan is equipped with a timer. |
VNV-1A(E) 80 I — the fan is equipped with an interval switch. |
CONTROL | |
|
|
The grille fixation to the fan while mounting provides regulation of tne front panel rotation angle with respect to the casing to conceal possible mounting inaccuracies. |
|
MOUNTING EXAMPLE | |
|
Characteristics
Characteristics
Parameter |
VENTS VNV-1A 80 speed 1 |
VENTS VNV-1A 80 speed 2 |
Measurement unit |
---|---|---|---|
Engine Type | 220В / 50Гц | 220В / 50Гц | - |
Voltage | 220-240 | 220-240 | V |
Frequency | 50 | 50 | Hz |
Power consumption | 12 | 17 | W |
Air capacity | 35 | 63 | m³/h |
Current | 0.12 | 0.14 | A |
RPM | 890 | 1350 | min-1 |
Sound pressure level at 3 m | 26.6 | 30 | dBА |
Maximum transported air temperature | 50 | 50 | °С |
Electric connection | 3×1.5 | 3×1.5 | mm² |
Spigot size | 80 | 80 | mm |
Design | centrifugal | centrifugal | - |
Duct diameter | 80 | 80 | mm |
IP Code | IP 55 | IP 55 | - |
Type | exhaust | exhaust | - |
Mounting | wall mounting, ceiling mounting | wall mounting, ceiling mounting | - |
Capacity diagram
Capacity diagram
- Selection method:
- Air flow:
- Pressure:
Operating point
- Air flow: --
- Pressure: ---
Files archieve
Downloads
Select document type
Dimensions
Characteristics
Parameter | Value | Measurement unit |
---|
Additional characteristics
Additional characteristics
Dimensions
Dimensions
Options description
Options description
Name | Description |
T timer modification |
The fan is switched on to the maximum speed manually with the external switch, turn-on delay time is 50 seconds. The return to default position is performed with the timer, run-out time is 6 minutes. Continuous low speed operation is possible. |
TR adjustable timer modification |
The fan can be switched to the maximum speed manually with the external switch. Turn-on delay time is set with the internal regulator ranging from 0 to 150 seconds. Run-out time is set with the internal regulator from 2 to 30 minutes. Continuous low speed operation is possible. |
I interval switch modification |
The fan switches periodically to the maximum speed while operation. The switching interval is set by means of the internal regulator ranging between 0.5 and 15 hours. Run-out time is 10 minutes. The fan can be switched manually with the external switch, turn-on delay time is 50 seconds. Continuous low speed operation is possible. |
H humidity sensor modification |
The fan switches to the maximum speed as relative humidity level in the room increases. It switches off as relative humidity level drops by 10 % below the set level. The humidity threshold is adjusted in the range between 60 % and 90 %. Force switching to the maximum speed is provided, in this case the turn-on delay time is 50 seconds, and the run-out time is set by the internal regulator between 2 and 30 minutes. Continuous low speed operation is possible. |
Video
Video
Accessories