VENTS VUT 800 WH-4
Air handling unit with the air flow up to 780 m³/h and heat recovery efficiency up to 78 % in sound-proof and heat-insulated casing with water heater
- Description
- Characteristics
- Capacity diagram
- Downloads
- Dimensions
- Additional characteristics
- Designation key
- Accessories
Description
Description
DESCRIPTION
|
AUTOMATION AND CONTROL SYSTEM
|
Characteristics
Characteristics
Parameter |
VUT 800 WH-4 |
Measurement unit |
---|---|---|
Frequency | 50/60 | Hz |
Phase | 1 | ˜ |
Voltage | 230 | V |
Maximum fan power | 2 pcs. x 245 | W |
Air capacity | 780 | m³/h |
Number of water (glycol) coil rows | 2 or 4 | - |
Fan current | 2 pcs. x 1.08 | A |
Total unit power | 490 | W |
Total unit current | 2.16 | A |
RPM | 1650 | min-1 |
Transported air temperature | -25...+40 | °С |
Sound pressure level at 3 m distance | 48 | dBА |
Heating | water heating | - |
Casing material | aluzinc | - |
Insulation | 50 mm mineral wool | - |
Filter: extract | G4 | - |
Filter: supply | G4 | - |
Connected air duct size | 250 | mm |
Weight | 88 | kg |
Heat recovery efficiency | up to 78 | % |
Heat exchanger material | polystyrene | - |
Heat exchanger type | cross-flow | - |
SEC Class | E | - |
Type | supply and exhaust with heat recovery | - |
Mounting | floor mounting | - |
Capacity diagram
Capacity diagram
- Selection method:
- Air flow:
- Pressure:
Operating point
- Air flow: --
- Pressure: ---
Files archieve
Downloads
Select document type
"Control system for air supply and air handling units based on Freemax controllers and AC208A2 sensor control panels" user's manual 07-2023 (V99EN-03) (pdf 7.14Mb)
Dimensions
Characteristics
Parameter | Value | Measurement unit |
---|---|---|
∅D | 249 | mm |
B | 613 | mm |
B1 | 460 | mm |
B2 | 306 | mm |
B3 | 386 | mm |
H | 698 | mm |
H1 | 832 | mm |
H2 | 154 | mm |
H3 | 280 | mm |
L | 1071 | mm |
L1 | 1117 | mm |
L2 | 1171 | mm |
Additional characteristics
Additional characteristics
Sound-power level | Octave-frequency band [Hz] | |||||||||
Hz | Gen | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 | |
LwA to inlet | dBA | 56 | 58 | 56 | 57 | 59 | 54 | 50 | 51 | 44 |
LwA to outlet | dBA | 57 | 58 | 61 | 60 | 55 | 53 | 51 | 48 | 45 |
LwA to environment | dBA | 35 | 43 | 46 | 38 | 43 | 29 | 29 | 26 | 23 |
Designation key
Designation key
Series | Rated air flow [m³/h] | Heater type | Duct connection | Row number of the heater | Service side (for VUT 1500 WH, VUT 2000 WH) |
VENTS VUT | 350; 500; 530; 600; 800; 1000; 1500; 2000 | W: water | H: horizontal | 2: two rows 4: four rows |
L: left side R: right side |
Accessories
Accessories
Model | G4 panel filter | Silencers | Back valves | Air dampers | Clamps | Summer blocks | |
VUT 800 WH-4 | SF 550x253x48 G4 | SR 250 600/900/1200 | SRF 250 600/900/1200 | KOM 250 | KR 250 | C 250 | VL C4 300/300*2 |
VUT 1000 WH-4 | SF 780x273x48 G4 | SR 315 600/900/1200 | SRF 315 600/900/1200 | KOM 315 | KR 315 | C 315 | VL C4 300/384 |
VUT 1500 WH-4 | SF 550x253x48 G4 | SR 250 600/900/1200 | SRF 250 600/900/1200 | KOM 250 | KR 250 | C 250 | VL C4 300/300*2 |