VENTS VUTR 900 EH EC


Air handling unit in heat- and sound-insulated casing with an electric heater. Air flow up to 900 m³/h. Heat recovery efficiency up to 95 %.

  • Description
  • Characteristics
  • Capacity diagram
  • Downloads
  • Dimensions
  • Designation key
  • Accessories
Description
Description
DESCRIPTION
  • The air handling units VUTR EH EC with an electric heater are the fully-featured ventilation units that ensure air filtration, fresh air supply and stale air extract.
  • Used in ventilation and air conditioning systems in commercial, office and other public or industrial premises that require an economical solution and a controlled ventilation system.
CASING
  • The casing consists of a frame and three-layer 20 mm (VUTR 1500 and 2000 – 25 mm) thick panels made of zinc aluminium internally filled with mineral wool for reliable heat- and sound-insulation.
MOTOR
  • The air handling units are equipped with high-efficiency electronically commutated (EC) direct current motors with an external rotor and backward-curved blades.
ROTARY HEAT EXCHANGER
  • Units equipped with a rotary heat exchanger.
  • As compared to plate heat exchangers, the rotary heat exchangers are distinguished with no condensate forming, ability to maintain comfortable air humidity and extremely low freezing danger.

HEATER
  • The air handling units are equipped with electric heaters to operate at low outside temperatures.
  • The heaters are equipped with protecting devices to ensure safe and reliable operation of the unit.
FILTER
  • The two integrated G4 filters ensure sufficient supply and extract air purification.

CONTROL AND AUTOMATION
  • The VUTR EH EC A17 units are equipped with a th-Tune control panel.

  • The VUTR EH EC A18 units are equipped with a pGD1 control panel.

AUTOMATION FUNCTIONS
  • Speed selection: low, medium, high.
  • Speed is individually adjusted from 0 to 100 % for the supply and the extract fans.
  • Filter maintenance indication.
  • Alarm indication.
  • Timer-based operation.
  • Week-scheduled operation.
  • Supply air temperature control.
  • CCU control.
  • Air damper actuator controlling.
APPLICATION OPTIONS  

Characteristics
Characteristics
Parameter VUTR 900 EH EC
Measurement unit
Frequency 50/60 Hz
Phase 3 ˜
Voltage 400 V
Maximum fan power 2 x 135 W
Electric heater power 4500 W
Sound pressure level at 3 m distance 58 dBА
Total unit current 7.2 A
Maximum air capacity 900 m³/h
Total unit power 4940 W
RPM 2600 min-1
Heat recovery efficiency 72...95 %
Transported air temperature -25 ... +40 °С
Casing material aluzinc -
Insulation 20 mm mineral wool -
Filter: extract G4 -
Filter: supply G4 -
Connected air duct size 250 mm
Weight 130 kg
Heat exchanger type rotary -
Heat exchanger material aluminium -
SEC Class A -
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
Download high quality image "VENTS VUTR 400, 700, 900 EH/WH EC (ErP 2016, 2018)" (psd 4.08Mb)
"VENTS VUTR EH/WH EC" product description 01-2023 (pdf 3.51Mb)
"VENTS VUTR EH EC" user's manual 02-2019 (V76EN-06) (pdf 8.53Mb)
Download image "VENTS VUTR 400, 700, 900 EH/WH EC (ErP 2016, 2018)" for your website (png 215.48Kb)
Download high quality image "VENTS VUTR 1200, 1500 EH/WH EC (ErP 2016, 2018)" (psd 4.49Mb)
Download image "VENTS VUTR 1200, 1500 EH/WH EC (ErP 2016, 2018)" for your website (png 356.99Kb)
Download high quality image "VENTS VUTR 2000 EH/WH EC (ErP 2016, 2018)" (psd 4.5Mb)
Download image "VENTS VUTR 2000 EH/WH EC (ErP 2016, 2018)" for your website (png 220.47Kb)
"BMS parameter table for PCOS004850 module for VUTR units" user’s manual 10-2020 (V197-3EN-02) (pdf 65.99Kb)
Dimensions
Characteristics
VENTS VUTR 900 EH EC
Parameter Value Measurement unit
∅D 249 mm
A 1210 mm
E 243 mm
F 180 mm
G 340 mm
J 580 mm
H 700 mm
L 745 mm
L1 260 mm
Designation key
Designation key
Series Heat exchanger type Rated air flow [m³/h] Heater type Pipe modification Motor type Control panel
VENTS VUT R: rotary heat exchanger 400; 700; 900; 1200; 1500; 2000 E: electric H: horizontal ЕС: synchronous motor with electronic control А17: th-Tune
А18: pGD1
Accessories
Accessories
Model G4 supply pocket filter G4 extract panel filter Module Modbus-RS485 Outdoor air quality sensor Outdoor CO2 sensor Outdoor humidiry sensor Outdoor humidiry sensor Indoor humidiry sensor (0-10 V) Back valves Air damper Electric actuator
 
VUTR 400 EH ЕС SFK 393x235x27 G4 SF 600x324x48 G4 PCOS004850 DPWQ30600 DPWQ40200 DPWC11200 HR-S HV-2 KOM 160 KRV 160 CM230
VUTR 700 EH ЕС SFK 700x333x27 G4 SF 700x332x48 G4 KOM 250 KRV 250
VUTR 900 EH ЕС
VUTR 1200 EH ЕС SFK 700x423x27 G4 SF 700x410x48 G4 KOM 315 KRV 315
VUTR 1500 EH ЕС SFK 800x477x27 G4 SF 800x477x47 G4
VUTR 2000 EH ЕС KOM1 500x300 KR 500x300