VENTS VUTR 280 VE EC


Air handling unit in heat- and sound-insulated casing
Air flow up to 300 m³/h
Heat recovery efficiency up to 90 %

  • Description
  • Characteristics
  • Capacity diagram
  • Downloads
  • Dimensions
  • Additional characteristics
  • Designation key
  • Accessories
Description
Description
DESCRIPTION
  • The VUTR VE EC air handling units are the fully-featured ventilation units that ensure air filtration, fresh air supply and stale air extraction.
  • Used in ventilation that require an economical solution and a controlled ventilation system.
CASING
  • Made of polymer-coated steel, internally filled with a mineral wool heat- and sound-insulating layer.
KITCHEN HOOD
  • All units are equipped with a 5th spigot for connection of a kitchen hood (see the «Application options» section).
  • The distinctive feature of the VUTR 200 VE2 EC unit is the ability to connect a KH-1 kitchen hood (available upon separate order) directly to the unit.

FILTER
  • The two integrated G4 and F7 filters ensure sufficient intake air purification.
  • Extract air is cleaned by the integrated G4 filter.

MOTOR
  • The units are equipped with high-efficient EC motors with an external rotor and a centrifugal impeller.
  • These state-of-the-art motors offer the very best in energy efficiency today.
ROTARY HEAT EXCHANGER
  • Unit equipped with a rotary heat exchanger.
  • As compared to plate heat exchangers, the rotary heat exchangers are distinguished with no condensate forming, ability to maintain comfortable air humidity and extremely low freezing danger.

HEATER
  • Units are equipped with an electric heater.
  • The heaters are equipped with protecting devices to ensure safe and reliable operation of the unit.
MOUNTING
  • The unit is designed for wall or floor mounting.
  • The access for unit and filter maintenance is available from the front panel.
  • The service and the back panels can be rearranged allowing connection both on the right and on the left side.
AUTOMATION
  • The VUTR V(2)E EC 21 units are equipped with an integrated control system.
  • The A21 controller allows integrating the unit into the Smart Home system or BMS (Building Management Systems).
  • To control the unit using a mobile application via Wi-Fi, you need to download the VENTS Home mobile application.
CONTORL AND AUTOMATION
Functions A21
Control via Wi-Fi using a mobile application +
Control via a wired remote control panel А22 (option)
Control via a wireless remote control panel А22 Wi-Fi (option)
Control via a wired remote LCD control panel А25 (option)
BMS RS-485
Wi-Fi
Ethernet
MODBUS (RTU, TCP)
Service Vents Cloud Server +
Speed selection +
Filter replacement indication according to hour meter readings
Alarm indication full alarm description in the mobile application
Week-scheduled operation +
Timers +
Boost mode +
Fireplace mode +
Reheater connection integrated in E models, external reaheater cannot be connected
Cooler connection option
Kitchen hood connection option
Minimum supply air temperature control +
Humidity control option
CO2 controller option
VOC controller option
Fire alarm sensor connection option
*Option. The functionality is available when you purchase the appropriate accessory.
APPLICATION OPTIONS  
Characteristics
Characteristics
Parameter VUTR 280 VE EC
Measurement unit
Frequency 50/60 Hz
Phase 1 ˜
Voltage 230 V
Maximum unit power 845 W
Maximum unit current 4.7 A
Max. power of electric heater 650 W
Max. unit current without electric heater 1.9 A
Max. unit current of electric heater 2.8 A
Air capacity 300 m³/h
RPM 2050 min-1
Max. unit power without electric heater 195 W
Heat recovery efficiency 81...90 %
Transported air temperature -25 ... +40 °С
Sound pressure level at 3 m distance 26 dBА
Casing material painted steel -
Insulation 40 mm mineral wool -
Filter: extract G4 -
Filter: supply F7 -
Connected air duct size 125 mm
Weight 64 kg
Heat exchanger type rotary -
Heat exchanger material aluminium -
SEC Class A -
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
"VENTS VUTR VE EC" product description 01-2023 (pdf 3.42Mb)
"VENTS VUTR 200 V2(E) EC" user's manual 08-2021 (V140-1EN-04) (pdf 3.52Mb)
"VENTS VUTR 400(600) V(E) EC" user's manual 07-2020 (V140EN-04) (pdf 3.24Mb)
Download high quality image "VENTS VUTR VE EC (ErP 2015, 2016, 2018)" (psd 4.42Mb)
Download image "VENTS VUTR VE EC (ErP 2015, 2016, 2018)" for your website (png 346.36Kb)
"VENTS VUTR 280 V(E) EC" user's manual 06-2020 (V140-2EN-02) (pdf 2.31Mb)
"Wireless control system A21" user’s manual 09-2022 (V55-8EN-04) (pdf 415.1Kb)
"Modbus table for connecting A21 automation to BMS" user’s manual 09-2022 (V55-8-1EN-02) (pdf 162.96Kb)
"BMS parameter table for PCOS004850 module for VUTR units" user’s manual 10-2020 (V197-3EN-02) (pdf 65.99Kb)
Dimensions
Characteristics
VENTS VUTR 280 VE EC
Parameter Value Measurement unit
∅D 122 mm
B 508 mm
H 630 mm
H1 754 mm
L 598 mm
Additional characteristics
Additional characteristics
A-weighted sound power level Gen. Octave-frequency band [Hz] LpA, 3 m dBA LpA, 1 m dBA
dBA 63 125 250 500 1000 2000 4000 8000    
LwA to supply inlet dBA 54 47 42 50 44 41 39 39 31    
LwA to supply outlet dBA 69 63 56 65 59 55 50 52 46    
LwA to exhaust inlet dBA 54 47 41 41 43 33 31 34 30    
LwA to exhaust outlet dBA 65 61 50 61 55 46 43 46 40    
LwA to environment dBA 47 42 37 43 36 31 28 26 21 26 36
Designation key
Designation key
Series Heat exchanger type Rated air flow [m³/h] Mounting type Insulation thickness Heater type Motor type Control panel
VENTS VUT R: rotary 200; 280; 400; 600 V: vertical _: 40 mm
2: 20 mm
E: with an electric heater ЕС: synchronous motor with electronic control
A21
Accessories
Accessories
Model G4 panel filter F7 panel filter LCD control panel Control panel Control panel with Wi-Fi VOC sensor
(0-10 V)
CO2 sensor
(0-10 V)
Humidity sensor
(0-10 V)
Humidity sensor NO
VUTR 200 V2E EC A21 SF 284x103x60 G4 SF 284x103x60 F7 A25 A22 A22 Wi-Fi DPWQ30600 DPWQ40200 DPWC11200 HR-S
VUTR 280 VE EC A21 SF 400x196x40 G4 SF 400x196x40 F7
VUTR 400 VE EC A21 SF 436x196x40 G4 SF 436x196x40 F7
VUTR 600 VE EC A21 SF 536x220x40 G4 SF 536x220x40 F7

 

Model Humidity sensor
(0-10 V)
Kitchen hood Silencers Back valves Air dampers Clamps Electric actuator
VUTR 200 V2E EC A21 HV-2 KH-1 SR 125 SRF 125 KOM 125 KRV 125 C 125 LF230 TF230
VUTR 280 VE EC A21
VUTR 400 VE EC A21 SR 160 SRF 160 KOM 160 KRV 160 C 160
VUTR 600 VE EC A21 SR 200 SRF 200 KOM 200 KRV 200 C 200
Share your opinion

Questionnaire
Basic parameter for domestic fan selection