Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use

Centrifugal fan VENTS VN-1 80

  • Description
  • Modifications
  • Capacity diagram
  • Downloads
  • Certificates
  • Options description
Description
Description
APPLICATIONS  
  • Suitable for premises with mono-pipe ventilation system.
  • Mounting in kitchens, bathrooms, toilets, storerooms and other household areas.
DESIGN  
  • For wall surface mounting.
  • The front panel and the casing are made of high-quality durable ABS plastic.
  • Equipped with the plastic backdraft damper.
  • Connected with the main ventilation shaft with a flexible air duct.
  • Сonnecting branch pipe diameter 80 mm.
MOTOR  
  • Energy-efficient 2-speed motor on ball bearings with minimum energy demand.
  • Independent maintenance of pressure and air flow rate in the duct.
  • For precise characteristics, low noise level and safe operation each turbine is dynamically balanced while assembly.
MODIFICATIONS AND OPTIONS  
VN-1A(E) 80 T— the fans are equipped with a timer.
VN-1A(E) 80 TR —
 the fans are equipped with an adjustable timer.

VN-1A(E) 80 I — the fans are equipped with an interval switch.
VN-1A(E) 80 H — 
the fans are equipped with a humidity sensor.

CONTROL  
  • Speed switch is performed with the external manual switch. P3-1-300 speed switch for the three speed fan models and P2-1-300 for the two speed fan models. The speed switches are not included into the delivery set and are available upon order.
MOUNTING EXAMPLE
 
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Downloads
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
"VENTS VN" user's manual 11-2023 (V22EN-09) (pdf 2.34Mb)
Download high quality image "VENTS VN-1 80" (psd 2.63Mb)
"VENTS VN-1 80, VN 80" product description 09-2021 (pdf 321.87Kb)
Download image "VENTS VN-1 80" for your website (png 507.33Kb)
"VENTS VN E 80" user's manual 01-2022 (V22-1EN-07) (pdf 1.9Mb)
"VENTS VN. High-rise residential buildings ventilation" catalog 2021 (pdf 8.97Mb)
Certificates
Certificates
<p>
	Mark of conformity to the European Quality Standards and Electrical Safety issued by Association for Technical Inspection (Technischer Überwachungsverein, Germany).</p>

Mark of conformity to the European Quality Standards and Electrical Safety issued by Association for Technical Inspection (Technischer Überwachungsverein, Germany).

<p>
	CE mark means that the equipment is produced in compliance with the quality and safety standards provided by EU regulations for the given product type (marked by manufacturer).</p>

CE mark means that the equipment is produced in compliance with the quality and safety standards provided by EU regulations for the given product type (marked by manufacturer).

<p>
	Mark of conformity to the Polish Quality Standards and electrical safety issued by PCBC (Polish center for testing and certification). </p>

Mark of conformity to the Polish Quality Standards and electrical safety issued by PCBC (Polish center for testing and certification).

<p>
	Mark of conformity to the Slovak Quality Standards and electrical safety issued by EVPU (Slovakia).</p>

Mark of conformity to the Slovak Quality Standards and electrical safety issued by EVPU (Slovakia).

<p>
	Mark of conformity to the Ukrainian Quality Standards and electrical safety issued by UkrTEST.</p>

Mark of conformity to the Ukrainian Quality Standards and electrical safety issued by UkrTEST.

<p>
	Mark of conformity of the goods subject to obligatory certification in DSTR system as well as technical norms and standards acting in Russian Federation. Confirmed by the RosTEST certificates (Moscow). </p>

Mark of conformity of the goods subject to obligatory certification in DSTR system as well as technical norms and standards acting in Russian Federation. Confirmed by the RosTEST certificates (Moscow).

<p>
	Insulation class: double insulation.</p>

Insulation class: double insulation.

<p>
	Equipment protection rating.</p>

Equipment protection rating.

<p>
	Applicance protection class.</p>

Applicance protection class.

<p>
	Equipment protection rating.</p>

Equipment protection rating.

<p>
	Equipment protection rating.</p>

Equipment protection rating.

RoHS (Restriction of Hazardous Substances Directive) is the directive on the restriction of the use of certain hazardous substances, was adopted in February 2003 by the European Union. RoHS (Restriction of Hazardous Substances Directive) is the directive on the restriction of the use of certain hazardous substances, was adopted in February 2003 by the European Union.
<p>
	Equipment protection rating.</p>

Equipment protection rating.

<p>
	Equipment protection rating.</p>

Equipment protection rating.

<p>
	Equipment protection rating.</p>

Equipment protection rating.

Options description
Options description
Name Description
T
timer modification
The fan is switched on to the maximum speed manually with the external switch, turn-on delay time is 50 seconds. The return to default position is performed with the timer, run-out time is 6 minutes. Continuous low speed operation is possible.
TR
adjustable timer modification
The fan can be switched to the maximum speed manually with the external switch. Turn-on delay time is set with the internal regulator ranging from 0 to 150 seconds. Run-out time is set with the internal regulator from 2 to 30 minutes. Continuous low speed operation is possible.
I
interval switch modification
The fan switches periodically to the maximum speed while operation. The switching interval is set by means of the internal regulator ranging between 0.5 and 15 hours. Run-out time is 10 minutes. The fan can be switched manually with the external switch, turn-on delay time is 50 seconds. Continuous low speed operation is possible.
H
humidity sensor modification
The fan switches to the maximum speed as relative humidity level in the room increases. It switches off as relative humidity level drops by 10 % below the set level. The humidity threshold is adjusted in the range between 60 % and 90 %. Force switching to the maximum speed is provided, in this case the turn-on delay time is 50 seconds, and the run-out time is set by the internal regulator between 2 and 30 minutes. Continuous low speed operation is possible.
Share your opinion

Questionnaire
Please evaluate our updated site user friendliness