Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use

VENTS PL-10-1A series

VENTS PL-10-1A series
Normally open fire-resisting duct damper with thermal fuse and return spring.
Model features
  • For commercial buildings
  • For industrial buildings
  • Smoke extraction ventilation
  • Description
  • Downloads
  • BIM
Description
Description
APPLICATION INSTALLATION
  • A fire safety damper prevents the spread of smoke and fire via ventilation and air conditioning system ducts in the event of fire. Such units are installed in ventilation duct channels which cross fire-separation walls and ceilings. The fire resistance rating according to EN 1366-2 is EIS 60 or EIS 120.
DESIGN
  • The PL series dampers are made in the general-purpose industrial version with a minimized variety of hardware components using low-alloy galvanized steel. The flap is made of fire-resistant material (vermiculite) with thermoexpansive fireproof sealing. The duct design implies two connection ports for integration into a ventilation duct (duct system).
  • The PL-10-1A series dampers are equipped with mechanical actuating unit with a thermal fuse and a return spring.
  • The fire safety damper remains open in the protective position. The damper is set to the operating position upon the thermal fuse breakdown resulting from a temperature increase. In the event of fire, the fusible element will melt upon the temperature reaching 72°C and the spring will set the flap to the closed position.
  • During the fire safety damper installation make sure that the release mechanism and the inspection hole face an easily accessible side of the wall or ceiling. This will ensure convenient control of the thermally sensitive release mechanism and its internals. The damper can be embedded into brick or concrete walls with the appropriate fire resistance rating. Wooden spreader bars should be used to avoid casing deformation during the installation.
Use of wooden spreader bars during installation
  • Upon completing the installation remove the wooden spreader bars.
Recommended damper positions
  • The damper may not be installed:
    • Into air ducts and on premises rated explosion and fire safety category A and B.
    • Into air ducts of local intakes for flammable and explosive mixtures.
    • Into systems which are do not undergo periodic cleaning pursuant to the established regulations for prevention of flammable deposit buildup.
INSTALLATION RECOMMENDATIONS  
in vertical building structures in horizontal building structures
Downloads
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
"VENTS PL-10" product description 03-2023 (pdf 1.06Mb)
Download high quality image "PL-10-1A" (psd 2.03Mb)
Download image "PL-10-1A" for your website (png 618.95Kb)
"Dampers KP, PL" user's manual 05-2023 (V58-1EN-04) (pdf 3.41Mb)
RFA models "PL-10" (rfa 956Kb)
BIM
BIM

Share your opinion

Questionnaire
Basic parameter for domestic fan selection