VENTS Non-insulated air ducts Thermovent series

VENTS Non-insulated air ducts Thermovent series

Semi-flexible galvanized or stainless steel air ducts.

Model features
  • Ventilation ducts and fittings
  • Description
  • Downloads
Description
Description
DESCRIPTION FEATURES
  • Semi-flexible stainless or galvanized steel spiral seam air ducts with high aerodynamic and strength characteristics.
  • Made of incombustible, corrosion-resisting stainless steel or galvanized steel band.
  • Increased thermal resistance (up to 700°С).
  • Superdense high-quality triple locks ensure high seam tightness and total air tightness of the ducts.
  • Low dynamic losses.
  • Low weight and easy mounting.
RECOMMENDED APPLICATION
  • Applied in residential and industrial ventilation, air conditioning and heating systems with the maximum pressure 10 000 Pa.
  • For supply and exhaust ventilation.
  • Applied in the systems of hot air removal from boiler houses and smoke exhaust systems.
TECHNICAL DATA:  
   
Item Thermovent N, Zn Thermovent N Thermovent S
Diameter range [mm] 80/100/110/120/125/130/140/150/160/180/200/250/315
Material Galvanized steel Stainless steel Stainless steel
Number of layers 1 1 1
Total thickness [μm] 80 80 100
Operating temperature range [°C] -30 +700 -30 +700 -30 +700
Maximum air speed [m/s] 30 30 30
Maximum operating pressure [Pa] 10000 10000 10000
Minimum bend radius [mm] 3хD 3хD 3хD
Length [m] 1; 2; 3; 6 1; 2; 3; 6 1; 2; 3; 6
   
PRESSURE LOSS DIAGRAM PER 1 M STRETCHED AIR DUCT CALCULATION EXAMPLE:
 
  1. Select a curve that matches the air duct diameter [mm], 200 mm in this case.
  2. Find the intersection point of this line with the vertical line of the required air flow in m3/h, 500 m3/h in this case.
  3. The horizontal line that shows the pressure loss in Pa per 1 m straight air duct crosses this intersection point.
  4. Multiply pressure loss value (2.4 Pa/m at 20°С) by total air duct length to get the total pressure loss value. To calculate pressure loss in case of bends consider each bend as extra air duct meter.
Downloads
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
"Thermovent" product description 09-2015 (pdf 127.34Kb)
Download high quality image "Thermovent" (psd 1.22Mb)
Download image "Thermovent" for your website (png 322.08Kb)
Share your opinion

Questionnaire
Please evaluate our updated site user friendliness