Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use

VENTS VUT 270 V5B EC


Air handling unit in heat- and sound-insulated casing.
Air flow up to 300 m³/h.
Heat recovery efficiency up to 98 %.

3D model
Gallery
  • Description
  • Characteristics
  • Capacity diagram
  • Downloads
  • Dimensions
  • Additional characteristics
  • Automation unit dimensions
  • Designation key
  • Video
  • Accessories
Description
Description
DESCRIPTION CASING
  • The air handling units are the fully featured ventilation units with heat recovery for air filtration, fresh air supply and stale air extract.
  • The casing is made of 15-26 mm thick expanded polypropylene (EPP), possessing high heat- and sound-insulating properties.
FILTER FANS
  • Supply and extract air flows are purified through G4 panel filters.
  • For extra supply air filtration a F8 filter is available as a specially ordered accessory.
  • High-efficient electronically commutated motors with external motor and impeller with backward curved blades.
 
HEAT EXCHANGER  
  • The VUT 270 V5B EC units are equipped with a counter- flow polystyrene heat exchanger.

  • The VUE 270 V5B EC units are equipped with an enthalpy counter-flow heat exchanger.

BYPASS AUTOMATION
  • The VUT/VUE 270 V5B EC units are equipped with a bypass for summer ventilation (cooling of the premise with a cool outside air).
FREEZE PROTECTION
  • For VUT/VUE 270 V5B EC A14 the freeze protection is realized by means of shutdown the supply fan.
  • For VUT/VUE 270 V5B EC A21 the freeze protection is realized by means of turning the preheater (available as an accessory) on.
INSTALLATION
  • The units are designed for wall and floor mounting.
  • The access for unit and filter maintenance is available on the right and left side.
  • The VUT/VUE 270 V5B EC A21 units are equipped with control system.
  • The A21 controller allows integrating the unit into the Smart Home system or BMS (Building Management Systems).
  • The unit is controlled via Wi-Fi by means of the VENTS Home mobile application that must be downloaded.
  • The VUT/VUE 270 V5B EC A14 units are equipped with integrated control system and wall-mounted sensor control panel A14 with LED indication.
CONTROL AND AUTOMATION  
Functions A21 A14
External wired control panel option (A22)
А14
Wired remote LCD control panel option (А25)
-
External wireless control panel option (A22 Wi-Fi)
-
BMS RS-485
Wi-Fi
Ethernet
MODBUS (RTU, TCP)
-
Service Vents Cloud Server + -
Wi-Fi control via mobile application + -
Speed selection + +
Filter replacement indication according to filter timer according to filter timer
according to pressure switch of filter clogging -
Alarm indication full alarm description in the mobile application alarm LED indication
Week scheduled operation + -
Bypass auto -
manual manual
Timer + -
Boost mode + -
Fireplace mode + -
Freeze protection cyclic shutdown of supply fan cyclic shutdown of supply fan
preheating (option) -
Reheater connection option -
Cooler connection option -
Control of minimum supply air temperature + -
Humidity control option option
CO2 control option option
VOC control option -
PM2.5 control option -
Fire detector option option
*Option. The function is available in case of mounting a respective accessory.
UNIT DESIGN  
APPLICATION OPTIONS  
Characteristics
Characteristics
Parameter VUT 270 V5B EC
Measurement unit
Frequency 50/60 Hz
Phase 1 ˜
Voltage 230 V
Maximum unit power 162 W
Maximum unit current 1.2 A
Air capacity 300 m³/h
RPM 3200 min-1
Heat recovery efficiency 87...98 %
Transported air temperature -25 ... +40 °С
Sound pressure level at 3 m distance 34 dBА
Insulation EPP 15…26 mm -
Casing material expanded polypropylene -
Filter: extract G4 -
Filter: supply G4, * F8 -
Connected air duct size 125 mm
Weight 13 kg
Heat exchanger type counter-flow -
Heat exchanger material polystyrene -
SEC class for A14, A21 A+ -
Option* -
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
Software "Setting air handling units with automation A14 and A15" (rar 17.47Mb)
"VENTS VUT/VUE 270 V5B EC" product description 01-2023 (pdf 1.9Mb)
"VENTS VUT/VUE 270 V5(B) EC" user's manual 08-2023 (V170-1EN-08) (pdf 2.4Mb)
Download high quality image "VENTS VUT/VUE 270 V5B EC (ErP 2015, 2016, 2018)" (psd 4.6Mb)
Download image "VENTS VUT/VUE 270 V5B EC (ErP 2015, 2016, 2018)" for your website (png 469.58Kb)
"Wireless control system A21" user’s manual 09-2022 (V55-8EN-04) (pdf 415.1Kb)
"Modbus table for connecting A21 automation to BMS" user’s manual 09-2022 (V55-8-1EN-02) (pdf 162.96Kb)
Dimensions
Characteristics
VENTS VUT 270 V5B EC
Parameter Value Measurement unit
∅D 125 mm
B 590 mm
H 893 mm
L 316 mm
Additional characteristics
Additional characteristics
A-weighted sound power level Gen. Octave-frequency band [Hz] LpA, 3 m dBA LpA, 1 m dBA
dBA 63 125 250 500 1000 2000 4000 8000    
LwA to supply inlet dBA 82 65 63 65 80 74 74 68 64    
LwA to supply outlet dBA 66 60 56 55 63 58 49 40 33    
LwA to exhaust inlet dBA 85 64 67 71 81 77 79 75 67    
LwA to exhaust outlet dBA 71 51 64 62 68 60 60 50 42    
LwA to environment dBA 55 37 45 44 53 43 43 40 38 34 44

 

Calculation of air temperature at heat exchanger outlet:

t = toutd + khr * (textr - toutd) / 100,

where
toutd is outdoor air temperature [°C]
textr is extract air temperature [°C]
khr is heat exchanger efficiency (according to the diagram) [%]

Exhaust air spigot configuration Air flow [l/s] Specific fan power [W/l/s] Recovery efficiency [%]
Kitchen + 1 additional wet room 21 0.73 85
Kitchen + 2 additional wet rooms 29 0.86 84
Kitchen + 3 additional wet rooms 37 1.08 82
Kitchen + 4 additional wet rooms 45 1.39 81
Automation unit dimensions
Automation unit dimensions
  Dimensions [mm]
  L1 L2 L3 H1 H2 H3
External automation unit (only units with A21 automation) 324 313 93 180 330 196
Designation key
Designation key
Series Rated air flow [m³/h] Installation type Casing design Bypass Motor type Control
VUT: ventilation with heat recovery
VUE: ventilation with energy recovery
270 V: vertical 5: expanded polypropylene (EPP) B: integrated bypass ЕС: synchronous electronically commutated motor A14
А21
Video
Video

Accessories
Accessories
Model G4 panel filter F8 panel filter LCD control panel Control panel Wi-Fi controllable control panel Internal humidity sensor CO2 sensor with indication CO2 sensor Humidity sensor
VUT 270 V5B EC A21 SF 264x182x18 G4 SF 264x182x18 F8 А25 А22 А22 Wi-Fi HV2 CO2-1 CO2-2 HR-S
VUE 270 V5B EC A21
VUT 270 V5B EC A14
VUE 270 V5B EC A14

 

Model VOC sensor
(0-10 V)
CO2 sensor
(0-10 V)
Humidity sensor
(0-10 V)
Reheater Preheater Syphon kit Air damper Electric actuator
VUT 270 V5B EC A21 DPWQ 30600 DPWQ 40200 DPWС 11200 NKD 125  NKP 125 SH-32 KRV 125 LF230
VUE 270 V5B EC A21
VUT 270 V5B EC A14 SH-32
VUE 270 V5B EC A14
Share your opinion

Questionnaire
Is our site helpful for your business development?