Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use

VENTS VKP 300x150 M1 EC


Centrifugal fans with the air capacity up to 565 m³/h for rectangular ducts.

  • Description
  • Characteristics
  • Capacity diagram
  • Downloads
  • Dimensions
  • Additional diagrams
  • Designation key
Description
Description
APPLICATIONS INTEGRATED FUNCTIONS AND CONTROL
  • Supply and exhaust ventilation and air conditioning systems for various premises requiring cost-effective solution and controlled ventilation.
  • EC motors in VKP fan reduce energy consumption by 1,5-3 times and ensure high performance and low noise level.
  • Such characteristics are of special importance for ventilation of banks, supermarkets, restaurants, hotels and other public facilities including swimming pool ventilation.
  • The fans are compatible with 300х150, 400х200, 500х250, 500х300, 600х300, 600х350, 700х400, 800х500, 900х500, 1000х500 mm rectangular ducts.
  • The fan is controlled with the external control signal 0-10 V (air capacity as a function of temperature level, pressure and smoke conditions etc).
  • Should the control value factor get changed the EC-motor changes its speed and the fan boosts as much air capacity to the ventilation system as required.
  • Maximum speed of the fan does not depend on the current frequency and it can operate at 50 or 60 Hz mains supply.
  • The fans can be integrated to the unified PC control system. The respective software allows controlling all the fan units with high accuracy and setting particular operation mode for each fan.
 DESIGN  MOTOR
  • Fan casing is made of galvanized steel.
  • All inner components are interconnected by means of rivets.
  • The fan is equipped with 20 mm standard flanges.
 MOUNTING
  • The fans are mounted into the rectangular ducts.
  • The fans can be mounted in any position with respect to the airflow direction which is indicated with a pointer on the casing.
  • Access for the fan maintenance shall be provided.
  • The casing is equipped with a removable access door for inspection and maintenance purposes.
  • The impellers with backward-curved blades are powered with high efficient electronically commutated (EC) direct current motors with external rotor. As of today, such motor type is the most advanced solution for energy saving. 
  • EC motors in VKP fan reduce energy consumption by 1,5-3 times and ensure high performance and low noise level.
  • EC-motors are featured by high performance and the optimal control over the whole range of fan speeds.
  • Premium efficiency reaching up to 90% is an absolute advantage of electronically commutated motors.
  
   
 VENTS VKP EC fan school class ventilation example  VENTS VKP EC fan car parking stand ventilation example
   
   
Characteristics
Characteristics
Parameter VKP 300x150 M1 EC
Measurement unit
Frequency 50/60 Hz
SEC class* * The EC norm 1254/2014 does not apply if maximum air capacity is >1000 m³/h B -
Phase 1 ˜
Voltage 230 V
Power consumption 97 W
Maximum air capacity 565 m³/h
RPM 3300 min-1
Current 0.73 A
EC motor yes -
Max. transported air temperature -25 +50 °С
Protection rating IP X4 -
Design centrifugal -
Weight 5.5 kg
Sound pressure level at 3 m distance 44 dBА
Casing material galvanized steel -
Duct for rectangular air ducts -
Type supply and exhaust -
Mounting Inline -
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
"VENTS VKP EC" product description 09-2023 (pdf 4.18Mb)
Download high quality image "VENTS VKP EC (ErP 2018)" (psd 2.42Mb)
"VENTS VKP EC" user's manual 11-2022 (V197EN-02) (pdf 1.9Mb)
Download image "VENTS VKP EC (ErP 2018)" for your website (png 397.26Kb)
"VENTS VKP, VKPI, VKPF, VKPFI, VKP EC, VKPI EC" user's manual 08-2022 (V07EN-05) (pdf 3.61Mb)
Dimensions
Characteristics
VENTS VKP 300x150 M1 EC
Parameter Value Measurement unit
В 300 mm
B1 320 mm
B2 340 mm
H 150 mm
H1 170 mm
H2 190 mm
H3 228 mm
L 350 mm
Additional diagrams
Additional diagrams
Sound power level, A-filter applied Sound pressure level at 3 meters, A-filter applied Sound pressure level at 1 meter, A-filter applied
Sound-power level, A - weighted General Octave frequency band [Hz]
  Hz 63 125 250 500 1000 2000 4000 8000 LpA, 3 m [dBA] LpA, 1 m [dBA]
LwA to inlet dBA 75 53 63 69 72 63 62 63 55 54 64
LwA to outlet dBA 78 57 63 70 73 69 71 68 60 57 67
LwA  to environment dBA 64 35 51 53 62 58 54 48 40 44 54

 

Designation key
Designation key
Series Flange diameter [WxH] Motor modification Phase Motor
VENTS VKP 300х150, 400х200, 500х250, 500х300, 600х300, 600х350, 700х400, 800х500, 900х500, 1000х500

M: medium pressure motor
L: high pressure motor

1: single phase
3: three phase
ЕС - synchronous electronically commutated motor
Accessories Similar products
Share your opinion

Questionnaire
Please evaluate our updated site user friendliness