VENTS VUT 250 VB EC L/R


Air handling unit in heat- and sound-insulated casing.
Air flow up to 390 m³/h.
Heat recovery efficiency up to 95 %.

  • Description
  • Characteristics
  • Capacity diagram
  • Downloads
  • Dimensions
  • Additional characteristics
  • Designation key
  • Accessories
Description
Description
DESCRIPTION
  • The air-handling units are the fully featured ventilation units with heat recovery for air filtration, fresh air supply and stale air extraction.
CASING
  • Made of high-quality polymer coated steel, internally filled with mineral wool layer for heat and sound insulation.
FILTER
  • Supply and exhaust air flows are purified through panel filters with filtering class G4 and F7, respectively.
  • Filters with G4 filtering class are used for supply and exhaust air purification in the VUT/VUE 250 VB EC units.
  • F7 filter is available as an option for supply air filtration.

FANS
  • The units are equipped with high-efficient EC motors with an external rotor and a centrifugal impeller with backward curved blades.
HEAT EXCHANGER
  • The VUT V(B) EC units are equipped with a counter-flow polystyrene heat exchanger.

  • The VUE V(B) EC units are equipped with a counter-flow enthalpy heat exchanger.

BYAPASS
  • The VUT/VUE VB EC units are equipped with a bypass for summer сooling.
FREEZE PROTECTION
  • In the VUT/VUE 160/350/550 VB EC A21 units it is possible to connect a preheater to protect the unit from freezing.
  • The VUT 250 VB EC A21 unit is equipped with a built-in preheater for frost protection.
MOUNTING
  • The units are designed for wall or floor mounting.
  • Access for maintenance of units and filters is possible from the right and left sides.
AUTOMATION
  • The VUT/VUE V(B) EC A21 units are equipped with a built-in automation system.
  • The A21 controller allows integrating the unit into the Smart Home system or BMS (Building Management Systems).
  • To control the unit via Wi-Fi, download the VENTS Home mobile app.
  • The VUT/VUE V(B) EC A14 units have an integrated control system with a wall-mounted control panel A14 with a LED indication.
CONTROL AND AUTOMATION
Functions A21 A14
Wired remote control panel Option (А22)
A14
Control via a wired remote LCD control panel Option (А25)
-
Wireless remote control panel Option (А22 Wi-Fi)
-
BMS RS-485
Wi-Fi
Ethernet
MODBUS (RTU, TCP)
-
Vents Cloud Server service + -
Control via Wi-Fi using a mobile application + -
Freeze protection + +
Bypass Auto + manual Manual
Week-scheduled operation + -
Filter replacement indication By the filter timer By the filter timer
According to filter clogging differential pressure switch readings (only for VUT/VUE 550 VB EC A21)
Alarm indication + +
Speed selection + +
Timers + -
RH% sensor Option Option
CO2 sensor Option Option
VOC sensor Option Option
PM2.5 sensor Option Option
Boost mode + -
Fireplace mode + -
Preheater connection Option (built-in preheater in VUT 250 VBE EC units) -
Reheater connection Option -
Cooler connection Option -
Fire alarm sensor Option Option
Minimum supply air temperature control + -
UNIT DESIGN  

VUT 350 VB EC

VUT(E) 250 VBE EC L/R

APPLICATION OPTIONS  
Characteristics
Characteristics
Parameter VUT 250 VB EC L/R
Measurement unit
Frequency 50/60 Hz
Phase 1 ˜
Voltage 230 V
Maximum unit power 180 W
Maximum unit current 1.37 A
Air capacity 390 m³/h
RPM 2600 min-1
Heat recovery efficiency 88...95 %
Transported air temperature -25 ... +40 °С
Weight 66 kg
Sound pressure level at 3 m distance 35 dBА
Casing material painted steel -
Heating without heating -
Insulation 30 mm mineral wool -
Filter: extract G4 -
Filter: supply G4 (F7*) -
Heat exchanger material polystyrene -
Heat exchanger type counter-flow -
SEC Class A+ -
Connection diameter 160 mm
Mounting floor mounting, wall mounting -
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
Software "Setting air handling units with automation A14 and A15" (rar 17.47Mb)
"VENTS VUT/VUE VB EC" product description 01-2023 (pdf 8.92Mb)
Download high quality image "VENTS VUT/VUE 160/350/550 VB EC (ErP 2015, 2016, 2018)" (psd 4.11Mb)
Download image "VENTS VUT/VUE 160/350/550 VB EC (ErP 2015, 2016, 2018)" for your website (png 326.64Kb)
"VENTS VUT/VUE 160/350/550 V(B) EC A14/A21" user's manual 10-2023 (V239EN-01) (pdf 3.05Mb)
"Sensor control panel A14/A15" user’s manual 04-2019 (V55-7EN-02) (pdf 1.16Mb)
"Wireless control system A21" user’s manual 09-2022 (V55-8EN-04) (pdf 415.1Kb)
"Modbus table for connecting A21 automation to BMS" user’s manual 09-2022 (V55-8-1EN-02) (pdf 162.96Kb)
Download image "VENTS VUT/VUE 250 VB EC (ErP 2015, 2016, 2018)" for your website (png 201.18Kb)
Download high quality image "VENTS VUT/VUE 250 VB EC (ErP 2015, 2016, 2018)" (psd 3.53Mb)
"VENTS VUT/VUE 250 VB(E) EC L/R" user's manual 01-2023 (V240EN-04) (pdf 2.45Mb)
Dimensions
Characteristics
VENTS VUT 250 VB EC L/R
Parameter Value Measurement unit
∅D 160 mm
B 560 mm
H 970 mm
L 560 mm
Additional characteristics
Additional characteristics

 

Point Power [W] Sound pressure level at 3 m distance [dBA]
1 180 35 (45)
2 179 35 (45)
3 168 35 (45)
4 63 24 (34)
5 57 24 (34)
6 52 23 (33)
7 15 18 (27)
8 15 17 (27)
9 14 17 (27)

 

A-weighted sound power level Gen. Octave frequency band [Hz] LpA, 3 m dBA LpA, 1 m dBA
dBA 63 125 250 500 1000 2000 4000 8000
LwA to supply air inlet dBA 70 51 55 59 64 65 63 54 49 59  
LwA to supply air outlet dBA 68 50 55 59 64 63 58 53 48 58  
LwA to exhaust air inlet dBA 76 28 58 66 70 68 69 62 55 65  
LwA to exhaust air outlet dBA 67 27 56 65 57 59 54 47 47 57  
LwA to environment dBA 56 24 50 49 47 45 48 45 35 45 36

  

Calculation of air temperature downstream of the heat exchanger:

t = toutd + khr * (textr - toutd) / 100,

where
toutd - outdoor air temperature [°C]
textr - extract air temperature [°C]
khr - heat exchanger efficiency (according to the diagram) [%]

Designation key
Designation key
Series Rated air flow [m³/h] Installation features Casing design Bypass Motor type Service side* Control
VUT: ventilation with heat recovery
VUE: ventilation with energy recovery
160, 250, 350, 550 V: vertical – by default
1: casing modification
_: without bypass
B: with bypass
ЕС: synchronous electronically commutated motor L: left
R:
right
А14
А21

* Only for VUT 250 VB EC L/R

Accessories
Accessories
Model G4 panel filter F7 panel filter LCD control panel Control panel Control panel with Wi-Fi Indoor humidity sensor CO2 sensor with indication CO2 sensor Humidity sensor
 
VUT 160 V ЕС A14 SF 285x195x10 G4 SF 285x195x10 F7 HV2 CO2-1 CO2-2 HR-S
VUE 160 V ЕС A14
VUT 160 VB ЕС A21 A25 A22 A22 Wi-Fi
VUT 160 VB ЕС A14
VUE 160 VB ЕС A21 A25 A22 A22 Wi-Fi
VUE 160 VB ЕС A14
VUT 160 V1 ЕС A14
VUE 160 V1 ЕС A14
VUT 160 V1B ЕС A21 A25 A22 A22 Wi-Fi
VUT 160 V1B ЕС A14
VUE 160 V1B ЕС A21 A25 A22 A22 Wi-Fi
VUE 160 V1B ЕС A14
VUT 250 VB EC A21 SF 340x170x48 G4 SF 340x170x48 F7 A25 A22 A22 Wi-Fi
VUT 250 VB EC A14
VUE 250 VB EC A21 A25 A22 A22 Wi-Fi
VUE 250 VB EC A14
VUT 350 V1B ЕС A21 SF 384х196х40 G4 SF 384х196х40 F7 A25 A22 A22 Wi-Fi
VUT 350 V1B ЕС A14
VUE 350 V1B ЕС A21 A25 A22 A22 Wi-Fi
VUE 350 V1B ЕС A14
VUT 350 VB EC A21 SF 500х196х40 G4 SF 500х196х40 F7 A25 A22 A22 Wi-Fi
VUT 350 VB EC A14
VUE 350 VB EC A21 A25 A22 A22 Wi-Fi
VUE 350 VB EC A14
VUT 550 VB ЕС A21 SF 630х198х40 G4 SF 630х198х40 F7 A25 A22 A22 Wi-Fi
VUT 550 VB ЕС A14
VUE 550 VB ЕС A21 A25 A22 A22 Wi-Fi
VUE 550 VB ЕС A14

 

Model VOC sensor
(0-10 V)
CO2 sensor
(0-10 V)
Humidity sensor
(0-10 V)
Kitchen hood Electric preheater Electric reheater Hydraulic U-trap Air damper Electric actuator Summer block
 
VUT 160 V ЕС A14 KH-1 SH-32 KRV 125 LF230 VL C6 366/285
VUE 160 V ЕС A14
VUT 160 VB ЕС A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-125 A21 V.2 NKD-125 A21 V.2 SH-32
VUT 160 VB ЕС A14
VUE 160 VB ЕС A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-125 A21 V.2 NKD-125 A21 V.2
VUE 160 VB ЕС A14
VUT 160 V1 ЕС A14 SH-32 VL C6 366/285
VUE 160 V1 ЕС A14
VUT 160 V1B ЕС A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-125 A21 V.2 NKD-125 A21 V.2 SH-32
VUT 160 V1B ЕС A14
VUE 160 V1B ЕС A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-125 A21 V.2 NKD-125 A21 V.2
VUE 160 V1B ЕС A14
VUT 250 VB EC A21 DPWQ30600 DPWQ40200 DPWС11200 NKD-160 A21 V.2 SH-32 KRV 160
VUT 250 VB EC A14
VUE 250 VB EC A21 DPWQ30600 DPWQ40200 DPWC11200 NKD-160 A21 V.2
VUE 250 VB EC A14
VUT 350 V1B ЕС A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-160 A21 V.2 NKD-160 A21 V.2 SH-32
VUT 350 V1B ЕС A14
VUE 350 V1B ЕС A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-160 A21 V.2 NKD-160 A21 V.2
VUE 350 V1B ЕС A14
VUT 350 VB EC A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-160 A21 V.2 NKD-160 A21 V.2 SH-32
VUT 350 VB EC A14
VUE 350 VB EC A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-160 A21 V.2 NKD-160 A21 V.2
VUE 350 VB EC A14
VUT 550 VB ЕС A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-200 A21 V.2 NKD-200 A21 V.2 SH-32 KRV 200
VUT 550 VB ЕС A14
VUE 550 VB ЕС A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-200 A21 V.2 NKD-200 A21 V.2
VUE 550 VB ЕС A14