Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use

VENTS VUT 3000 PE EC

  • Description
  • Characteristics
  • Downloads
  • Dimensions
  • Additional diagrams
  • Accessories
  • Legend
Description
Description
DESCRIPTION
  • The VUT PE EC air handling units with the electric heater are the fully-featured ventilation units ensure air filtration, fresh air supply and stale air extract.

  • The heat energy contained in extract air is transferred to supply air through the plate heat exchanger.

  • The units are suitable for integration into various ventilation and air conditioning networks requiring cost-effective solutions and controllable ventilation.

  • The integrated EC motors reduce energy demand by half up to three-fold and provide high air flow and low noise level.

  • All the models are compatible with round 160 (150), 200, 250, 315 and 400 mm air ducts.

MODIFICATIONS CASING
  • VUT PE EC – models with the electric heater.

  • The aluzinc casing is internally filled with 20 mm mineral wool for VUT 350, 600, 1000 PE EC and 25 mm for VUT 2000, 3000 PE EC units.

FILTER  
  • Supply and extract air flows are purified through two panel filters with filtering class G4. 

  • Supply filter F7 can be supplied with the few models.
MOTOR  
  • High-efficient electronically-commutated motors with external motor and impellers with backward curved blades.

  • Such motors are the most state-of-the-art energy-saving solution.

  • EC motors are featured with high performance and total speed controllable range.

  • High efficiency reaching 90% is the premium advantage of the electronically-commutated motors.

HEAT EXCHANGER  
  • VUT 350, 600 and 1000 PE EC models are fitted with a counter-flow heat exchanger made of aluminum. VUT 2000 and 3000 PE EC models are fitted with a cross-flow plate heat exchanger made of aluminum.

  • All the units are equipped with a drain pan for condensate drainage.

HEATER CONTROL AND AUTOMATION
  • The electric heater (for the unit VUT PE) the heat exchanger is designed for warming up of supply air up to the set level if heat recovery is not enough to attain the set supply air temperature.

  • The unit includes an integrated automation and a multifunctional control panel with a remote LCD control panel.
  • The delivery set includes a 10 m connecting cable for connection of the unit to the control panel.
  • The freezing protection function is performed by means of the bypass and the heater.
  • In case of a freezing danger according to the temperature sensor readings the bypass damper is opened to let supply air flow through the bypass duct and not come in contact with the heat exchanger.
  • The heater warms up supply air up to the required temperature and meanwhile the heat exchanger is heated by the warm extract air.
  • After the heat exchanger defrosting the bypass damper closes the bypass duct and the air handling unit reverts to the standard operation mode.

The VUT PE EC unit incorporates a LCD control panel

with a colour sensor display PU SENS 01.

VUT PE EC CONTROL AND PROTECTION FUNCTIONS  

Control panel:

  • Turning air handling unit on/off, room temperature indication, low-medium-high speed selection.
  • Opening/closing bypass for summer ventilation; timer mode activation, setting week scheduled operation (applicable only for PU SENS 01).
  • Supply and exhaust fan speed stage adjustment from 0 up to 100% during the system set-up.
  • Set indoor air maintaining by feedback of the sensor on the control panel.
  • Overheating protection for the electric heating elements according to feedback of the duct temperature sensor as well as signal from the two thermal switches, one of self-resetting type actuated at +60°C and the other one of manual reset type actuated at +90°C.
  • Cooling of the electric heating elements at the end of the heating cycle;
  • Actuating external air dampers.
  • Maintaining set indoor or room air temperature.
  • Control according to the duct humidity sensor feedback HV1 (special accessory) or according to the humidity sensor in the control panel.
  • Filter clogging control by filter timer.
  • Ventilation system shutdown at signal from the fire alarm system.
  • Cooler connection possibility.
MOUNTING
 
  • The unit is designed for indoor mounting. While mounting the unit ensure its correct position to enable condensate collection and drainage.

  • Access for servicing and cleaning of the filter is from the right or left side panel for the dimension types 350, 600 and 1000 and from the bottom for the dimension types 2000 and 3000.
ACCESSORIES  
  • For attenuation of sound generated by the fans it is recommended to install the duct silencer (refer SR) from inside before the unit.

  • For absorbing of vibration in the air duct it is recommended to install the flexible anti-vibration connectors (refer VVG) on both sides of the unit.

  • To disable uncontrollable air backdrafting during the fan standby and to prevent the water heater freezing the units must be equipped with automatic air dampers.
Characteristics
Characteristics
Parameter VUT 3000 PE EC
Measurement unit
Frequency 50/60 Hz
Phase 1 ˜
Voltage 400 V
Electric heater power 21,0 W
Maximum fan power 2 pcs. x 990 W
Electric heater current 30 A
Fan current 2 pcs. x 1.7 A
Total unit power 23000 W
Total unit current 33.4 A
Maximum air capacity 4000 m³/h
RPM 2580 min-1
Sound pressure level at 3 m distance 59 dBА
Transported air temperature -25 up to +40 °С
Casing material aluzinc -
Insulation 20 mm mineral wool -
Filter: extract G4 -
Filter: supply G4 -
Connected air duct size 400 mm
Number of water (glycol) coil rows - -
Weight 290 kg
Heat recovery efficiency up to 75 %
Heat exchanger type cross-flow -
Heat exchanger material aluminium -
SEC Class - -
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
Download high quality image "VENTS VUT 350, 600, 1000 PE EC (ErP 2016, 2018)" (psd 3.63Mb)
"VENTS VUT PE EC, VUT PW EC" product description 01-2019 (pdf 4.44Mb)
"VENTS VUT 350-600-1000 PE EC" user's manual 02-2019 (V68EN-10) (pdf 3.29Mb)
"VENTS VUT 2000-3000 PE EC" user's manual 05-2019 (V68-1EN-06) (pdf 4.28Mb)
"Control system for air supply and air handling units based on Freemax controllers and AC208A2 sensor control panels" user's manual 07-2023 (V99EN-03) (pdf 7.14Mb)
"LCD Control Panel PU JK 01" user's manual 11-2020 (V55-5EN-03) (pdf 4.85Mb)
Download high quality image "VENTS VUT 2000, 3000 PE EC (ErP 2016)" (psd 3.83Mb)
Download image "VENTS VUT 350, 600, 1000 PE EC (ErP 2016, 2018)" for your website (png 241.9Kb)
Download image "VENTS VUT 2000, 3000 PE EC (ErP 2016)" for your website (png 282.18Kb)
Dimensions
Characteristics
VENTS  VUT 3000 PE EC
Parameter Value Measurement unit
∅D 399 mm
B 1265 mm
B1 - mm
B2 563 mm
B3 347 mm
B4 570 mm
H 881 mm
H1 427 mm
L 1835 mm
L1 1888 mm
L2 - mm
Additional diagrams
Additional diagrams
Sound-power level Octave-frequency band [Hz]
  Hz General 63 125 250 500 1000 2000 4000 8000
LWA to inlet dBA 80 85 83 82 75 75 72 70 64
LWA to outlet dBA 86 87 86 83 77 80 75 75 74
LWA to environment dBA 61 70 69 63 58 51 48 42 41

 

Accessories
Accessories
Model G4 pocket filter F7 pocket filter G4 panel filter Outdoor humidity sensor Silencer Backdraft damper Air damper Clamps Electric actuators Mixing unit
   
VUT 350 PE ЕC SFK 208х236х27 G4 SFK 208х236х27 F7 SF 440х128х20 G4 HV1 SR 160 600/900/1200 SRF 160 600/900/1200 KOM 160  KRV С 160  LF 230 TF 230 -
VUT 600 PE ЕC SFK 392х236х27 G4 SFK 392х236х27 F7 >SF 782х128х20 G4 SR 200 600/900/1200 SRF 200 600/900/1200 КОМ 200 KRV 200 С 200 LF 230 TF 230 -
VUT 1000 PE ЕC SFK 647х274х27 G4 SFK 647х274х27 F7 SF 647х274х20 G4 SR 250 600/900/1200 SRF 250 600/900/1200 КОМ 250 KRV 250 С 250 LF 230 TF 230 -
VUT 2000 PE ЕC - - SF 708х480х48 G4 SR 315 600/900/1200 SRF 315 600/900/1200 КОМ 315 KRV 315 С 315 LF 230 TF 230 -
VUT 3000 PE ЕC - - SF 827х741х48 G4 SR 400 600/900/1200 SRF 400 600/900/1200 КОМ 400 KRV 400 С 400 LF 230 TF 230 -
Legend
Legend
Series Rated air flow, [m3/h] Mounting modification Heater type Motor type Service side Control
VENTS VUT 350; 600; 1000; 2000; 3000 P: suspended E: electric ЕС:synchronous electronically commutated motor
L: left
R: right
: PU SENS 01 control panel
Share your opinion

Questionnaire
How often do you use equipment selection program?