VENTS VUTR 200 V6EK EC
Air handling unit in a heat- and sound-insulated casing
Air flow is up to 270 m³/h
Heat recovery efficiency is up to 92 %
With an electric heater
Air flow is up to 270 m³/h
Heat recovery efficiency is up to 92 %
With an electric heater
- Description
- Characteristics
- Capacity diagram
- Downloads
- Dimensions
- Additional characteristics
- Designation key
- Accessories
Description
Description
DESCRIPTION
|
AUTOMATION
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
APPLICATION OPTIONS | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Characteristics
Characteristics
Parameter |
VUTR 200 V6EK EC |
Measurement unit |
---|---|---|
Frequency | 50/60 | Hz |
Phase | 1 | ˜ |
Voltage | 230 | V |
Maximum unit power | 818 | W |
Maximum unit current | 4.0 | A |
Max. unit current without electric heater | 1.0 | A |
Max. power of electric heater | 700 | W |
Max. unit current of electric heater | 3.0 | A |
Air capacity | 270 | m³/h |
RPM | 1800 | min-1 |
Transported air temperature | -25 ... +40 | °С |
Max. unit power without electric heater | 118 | W |
Heat recovery efficiency | 75...92 | % |
Sound pressure level at 3 m distance | 28 | dBА |
Insulation | 20 mm, mineral wool | - |
Heating | electric heating | - |
Casing material | painted steel | - |
Filter: extract | G4 | - |
Filter: supply | G4, F7 | - |
Weight | 48 | kg |
Heat exchanger type | rotary | - |
Heat exchanger material | aluminium | - |
SEC Class | A | - |
Connection diameter | 125 | mm |
Type | supply and exhaust with heat recovery | - |
Mounting | wall mounting | - |
Capacity diagram
Capacity diagram
- Selection method:
- Air flow:
- Pressure:
Operating point
- Air flow: --
- Pressure: ---
Files archieve
Downloads
Select document type
Dimensions
Characteristics
Parameter | Value | Measurement unit |
---|---|---|
Ø D | 125 | mm |
B | 348 | mm |
B1 | 371 | mm |
H | 791 | mm |
H1 | 865 | mm |
L | 598 | mm |
Additional characteristics
Additional characteristics
Calculation of air temperature downstream of the heat exchanger: |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Designation key
Designation key
Series | Heat exchanger type | Rated air flow [m³/h] | Mounting type | Casing design | Additional equipment | Motor type | Control panel |
VENTS VUT | P: rotary | 200 | V: vertical | 6: casing with a thin kitchen hood | E: with an electric heater K: kitchen hood |
EC: synchronous motor with electronic control | A21 |
Accessories
Accessories
Model | G4 panel filter | F7 panel filter | LCD control panel | Control panel | Control panel with Wi-Fi | VOC sensor 0-10 V |
CO2 sensor 0-10 V |
Humidity sensor 0-10 V |
Humidity sensor NO |
VUTR 200 V6K EC A21 | SF 284x103x60 G4 | SF 284x103x60 F7 | A25 | A22 | A22 Wi-Fi | DPWQ30600 | DPWQ40200 | DPWC11200 | HR-S |
VUTR 200 V6EK EC A21 |
Model | Humidity sensor | External CO2 sensor with indication | External CO2 sensor | Silencers | Back valves | Air dampers | Clamps | Electric actuator | ||
VUTR 200 V6K EC A21 | HV-2 | CO2-1 | CO2-2 | SR 125 | SRF 125 | KOM 125 | KRV 125 | C 125 | LF230 | TF230 |
VUTR 200 V6EK EC A21 |
Similar products