Air heating unit VENTS AOE
- Description
- Modifications
- Downloads
- Designation key
Description
Description
APPLICATION
- Designed for air heating in the room with electric heater and air uniform distribution due to an integrated fan and louvre shutters.
- The air heating units enable quick air heating of large premises or provide local heating of a work zone, for example, in big airplane shed or production facilities.
- The air heating units are designed for installation in manufacturing workshops, garages, car showrooms, stock houses, trade facilities, super- and hypermarkets, shops, sport halls, conference halls, poultry and cattle farms, greenhouses and other similar premises.
- The unit design enables quick and easy mounting and its operation reduces total investment costs for heating system.
DESIGN
- The AOE unit consists of an axial fan and an electric heater enclosed into a steel polymer coated casing.
- The electric heater is equipped with two overheating thermostats:
- the main overheating protection with automatic reset is activated at +50 °C. After the heater cooling the thermostat closes the heater control circuit.
- the alarm overheating protection with manual reset is activated at +90 °C. In case of alarm thermostat activation power supply to the heater is posible after manual alarm reset only.
FAN MOTOR
- AC motors with external rotor and built-in thermal overheating protection with automatic reset.
ADVANTAGES OF AIR HEATING:
- quick temperature increase in the room up to set point;
- low inertance of the system allows to provide alternating heating mode or heating in some zones;
- high heating efficiency;
- capital investments for air heating system is much less as compared to the similar water heating system.
|
CONTROL AND REGULATION
- For safe and correct operation the air heating unit must be controlled with integral control and protection automatic control system to provide the following functions:
- automatic power and heating temperature adjustment;
- power supply cut-off to the heater in case of the fan shutdown, low air flow or if integrated motor overheating thermostats are activated;
- air supply to the electric heating elements for heating removal after shutoff of the heating unit;
- power supply to the heater via an integrated automatic circuit breaker with tripping current depending on the heater power.
- The heating unit operation modes are controlled from UET-15D or UET-30D (available upon separate order) control unit.
- Air flow temperature is controlled by the heater on/off switch time (full heating power) in compliance with a set heating point.
- The control unit controls the fan speed and cuts off power supply to the heater in case of the fan shutdown or very low air flow.
- The control unit is designed for joint operation with digital TST-1-300 thermostats with sensor display (TSTD-1-300 model is equipped with a remote controller) or RTS-1-400 with LCD display (RTSD-1-400 is equipped with a remote controller). The thermostats are available on separate order.
- The thermostat is designed for indoor installation in the room heated by the air heating unit to determine its operation mode.
- The thermostat installation place must not be influenced by windows, doors and heating radiators.
- One thermostat is capable to control several connected air heating units in one room (max. 10 AOE units per each thermostat).
|
ACCESSORY SELECTION TABLE:
|
|
Air heating unit model |
Control unit |
Digital thermostat |
Mounting accessories |
|
|
with sensor display |
with LCD display |
Mounting angles |
Mounting brackets |
|
|
|
|
|
|
АОЕ 9 |
UET-15D |
TST-1-300
TSTD-1-300
|
RTS-1-400
RTSD-1-400
|
MKP-AOW |
MK-AOW 25 |
АОЕ 12 |
АОЕ 15 |
АОЕ 18 |
UET-30D |
MK-AOW 45 |
АОЕ 24 |
АОЕ 30 |
WARM AIR DISTRIBUTION
|
|
MOUNTING |
WARNING! |
- The air heating unit is suitable for vertical installation on the walls (beams) or horizontal installation on the ceiling (beams).
|
While mounting AOE units provide free air supply to the fan suction vent by keeping the minimum distance from the units to the wall or ceiling 300 mm. |
Designation key
Designation key
Series |
Rated power [kW] |
VENTS AOE |
9; 12; 15; 18; 24; 30 |