Description
APPLICATION  
  • Continuous or periodic exhaust ventilation of bathroom, showers, kitchens and other utility spaces.
  • Ventilation of premises with high noise level limitations.
  • Mounting into ventilation shafts or connection to Ø100 and 150 mm air ducts.
DESIGN  
  • The casing and the impeller are made of highquality durable ABS plastic, UV resistant.
  • Specially designed impeller aerodynamic profile provides high air flow and low noise.
  • The fan is equipped with a back valve to prevent back flow and heat losses during the fan standby.
  • The fan exhaust spigot incorporates specially designed air rectifiers to reduce air turbulence, increase air pressure and lower noise level.
MOTOR  
  • Low energy demand from 8 W due to new high-efficient motor.
  • Designed for continuous operation and requires no maintenance.
  • Motor equipped with overheating protection.
CONTROL  

Manual control:

  • Manual control by a room light switch. The switch is not included into the delivery set.
  • The fan is controlled by the built-in pull cord switch V. Not applied in case of ceiling mounting.
  • Speed control is possible through a thyristor/speed controller (see Electrical Accessories). Speed controllers can not be connected to the fans with the T, TH, TP, VT, VTH modification.

Automatic:

  • By the electronic control unit BU-1-60. The control unit is supplied separately.
  • By the timer T (the built-in adjustable turn-off delay timer enables the fan to operate within 2 to 30 minutes after the fan switching off).
  • By the timer T1 (the built-in adjustable turnon and turn-off delay timer turns on the fan in 0…2 min after the switch provides a control signal and allows it to operate from 2 to 30 minutes after opening of the switch).
  • By a humidity sensor and timer TH (if the humidity level in the room exceeds the sensor threshold adjustable value within 60-90% the fan switches automatically on and operates until the humidity level drops to the standard level, after that the fan continues operating within the time period according to the timer setting, then shuts down).
MOUNTING FEATURES  
  • The fan is mounted directly into the ventilation shaft.
  • Flexible duct application is recommended in case of remote location of the ventilation shaft.
  • The air duct is connected to the fan exhaust flange through a clamp.
  • Fixed to the wall by self-tapping screws.
  • Can be ceiling mounted in case the fan is ordered with ball bearings (Casto L modification).
MOUNTING EXAMPLE  
Modifications
Turn-off delay timer
Turn-on delay timer
Humidity sensor
Pull-cord switch
Ball bearing motor
Safe voltage (12 V)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Downloads
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
"VENTS Casto" product description 12-2019 (pdf 3.21Mb)
Download high quality image "VENTS Casto" (psd 2.34Mb)
Download image "VENTS Casto" for your website (png 588.01Kb)
"VENTS Casto" user’s manual 10-2020 (V215EN-01) (pdf 1.86Mb)
Certificates
Certificates
<p>
	Mark of conformity to the European Quality Standards and Electrical Safety issued by Association for Technical Inspection (Technischer Überwachungsverein, Germany).</p>

Mark of conformity to the European Quality Standards and Electrical Safety issued by Association for Technical Inspection (Technischer Überwachungsverein, Germany).

<p>
	Mark of conformity to the Polish Quality Standards and electrical safety issued by PCBC (Polish center for testing and certification). </p>

Mark of conformity to the Polish Quality Standards and electrical safety issued by PCBC (Polish center for testing and certification).

<p>
	Mark of conformity to the Slovak Quality Standards and electrical safety issued by EVPU (Slovakia).</p>

Mark of conformity to the Slovak Quality Standards and electrical safety issued by EVPU (Slovakia).

<p>
	Mark of conformity to the Ukrainian Quality Standards and electrical safety issued by UkrTEST.</p>

Mark of conformity to the Ukrainian Quality Standards and electrical safety issued by UkrTEST.

<p>
	Mark of conformity of the goods subject to obligatory certification in DSTR system as well as technical norms and standards acting in Russian Federation. Confirmed by the RosTEST certificates (Moscow). </p>

Mark of conformity of the goods subject to obligatory certification in DSTR system as well as technical norms and standards acting in Russian Federation. Confirmed by the RosTEST certificates (Moscow).

<p>
	Insulation class: double insulation.</p>

Insulation class: double insulation.

<p>
	Equipment protection rating.</p>

Equipment protection rating.

CE mark means that the equipment is produced in compliance with the quality and safety standards provided by EU regulations for the given product type (marked by manufacturer). CE mark means that the equipment is produced in compliance with the quality and safety standards provided by EU regulations for the given product type (marked by manufacturer).
Designation key
Designation key
PICTURE SYMBOL DESIGNATION MODIFICATION DESCRIPTION
Casto L The motor is equipped with ball bearings for long service life (appr. 40 thousand hours) and fan mounting at any angle. The bearings are maintenance-free and contain enough grease for the entire operating period.
Casto T An adjustable turn-off delay timer modification with operating time from 2 to 30 min.
Casto T1 Modification with a turnon delay timer (adjustable from 0 to 2 minutes) and a turn-off delay timer (adjustable from 2 to 30 minutes).
Casto TH An adjustable timer modification with the operating time from 2 to 30 min and a humidity sensor with threshold from 60 to 90%.
Casto V A pull-cord switch modification.
Casto VT Modification with a pull-cord switch and an adjustable timer with operating time from 2 to 30 min.td>
Casto VTH Modification with a pullcord switch, an adjustable timer with operating time from 2 to 30 min and a humidity sensor with threshold from 60 to 90%.