Centralised ventilation unit for small apartments Uni Max
Decentralized unit for the small offices, facilities, classrooms and living spaces. Air flow: up to 160 m³/h. Heat recovery efficiency: up to 95 %.
Model features
- Description
- Modifications
- Downloads
- Automation functions
- Product range
- Accessories
Description
Description
FEATURES | ||||||
|
|
|||||
CASING | PREHEATING | |||||
|
|
|||||
BYPASS | ||||||
|
||||||
AIR DAMPERS | HEAT RECOVERY | |||||
|
|
|||||
FANS | ||||||
|
||||||
AIR DISTRIBUTION | ||||||
CONTROL AND AUTOMATION | ||||||
|
|
|||||
MOUNTING | ||||||
Modifications
Downloads
Downloads
Select document type
Automation functions
Automation functions
Functions |
Uni Max A21 | Uni Max A14 | ||||
Unit control via Wi-Fi using a mobile application | + | – | ||||
Unit control via a wired remote control panel |
|
|
||||
Unit control via a wireless remote control panel |
|
– | ||||
Unit control via a remote wired LCD control panel |
|
– | ||||
BMS (Building Management System) | RS-485 | – | ||||
Wi-Fi | – | |||||
Ethernet | – | |||||
MODBUS (RTU, TCP) | – | |||||
Speed selection | + | + | ||||
Filter replacement indication | by filter timer | by filter timer | ||||
Alarm indication | full alarm description in the mobile application | + | ||||
Week-scheduled operation | + | – | ||||
Bypass | automatic | manual | ||||
manual | – | |||||
Timer | + | – | ||||
Boost mode | + | – | ||||
Fireplace mode | + | – | ||||
Freeze protection | through cyclic stops of the supply fan | through cyclic stops of the supply fan | ||||
through preheating (option) | – | |||||
Reheater connection | option | – | ||||
Cooler connection | option | – | ||||
Minimum supply air temperature control | option | – | ||||
Humidity control | option | option | ||||
CO2 control | option | option | ||||
VOC control | option | option | ||||
PM2.5 control | option | option | ||||
Fire alarm sensor connection | option | – |
Product range
Product range
Heat exchanger | Air dampers | Preheater | Bypass | |
Uni Max S14 | HRV | • | • | |
Uni Max S21 | • | • | ||
Uni Max E S21 | • | • | • | |
Uni Max ERV S14 | ERV | • | • | |
Uni Max ERV S21 | • | • | ||
Uni Max E ERV S21 | • | • | • |
Accessories
Accessories
Uni Max S14 Uni Max ERV S14 |
Uni Max S21 Uni Max E S21 |
Uni Max ERV S21 Uni Max E ERV S21 |
||
Coarse 90% / G4 panel filter | SF 233x175x22 Coarse 90% / G4 | |||
ePM1 70% / F7 panel filter | SF 233x175x22 ePM1 70% / F7 | |||
Control panel | - | A22 | ||
Wireless control panel | - | A22 Wi-Fi | ||
LCD control panel | - | A25 | ||
Humidity sensor | HV2 | |||
Humidity sensor | HR-S | |||
Humidity sensor | - | DPWC11200 | ||
CO₂ sensor with indication | CO2-1 | |||
CO₂ sensor | CO2-2 | |||
CO₂ sensor | CO2-3 | |||
CO₂ sensor | - | DPWQ40200 | ||
VOC sensor | - | DPWQ30600 | ||
Electric reheater | NKD 125 A21 V.2 series | |||
Outer grille | MVMA 125 bVn Al |