Mode | Voltage | Maximum air capacity | RPM | Weight | Voltage | Current | RPM | Air capacity | Pressure | Weight | IP Code | Sound pressure level at 3 m | Weight | Frequency | Form | Power consumption | Engine Type | Spigot size | Lamp power | Engine Type | SEC Class | Duct diameter | Design | Type | Material | Mounting | SFP | Maximum air capacity | Size | Air capacity | Panel compatibility |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | - | - | - | - | 220-240 | 0.105 | 2400 | - | - | - | IP 34 | 36 | 0.84 | 50 | - | 24 | - | 125 | - | 220-240V / 50Hz | - | 125 | axial | exhaust | - | wall mounting , ceiling mounting | - | - | - | 209 | - |
- | - | - | - | - | 220 | 0.071 | - | 65 | 50 | - | IP 24 | 37 | - | 60 | - | 10.59 | 220V / 60Hz | 100 | - | - | - | 100 | axial | exhaust | - | wall mounting , ceiling mounting | - | - | - | - | - |
- | - | - | - | - | 220 | 0.085 | 2300 | 99 | - | 0.60 | IP 24 | 33 | - | 60 | - | 14 | 220V / 60Hz | 100 | - | - | - | 100 | axial | exhaust | - | wall mounting , ceiling mounting | - | - | - | - | - |
- | - | - | - | - | 220 | 0.122 | 1506 | 161 | 45 | - | - | 41 | - | 60 | - | 18.79 | 220V / 60Hz | 125 | - | - | - | 125 | axial | supply and exhaust | - | Inline | - | - | - | - | - |
- | - | - | - | - | 220 | 0.122 | - | 195 | 52 | - | IP 34 | 39 | - | 60 | - | 17.62 | 220V / 60Hz | 125 | - | - | - | 125 | axial | exhaust | - | wall mounting , ceiling mounting | - | - | - | - | - |
- | - | - | - | - | 220 | 0.099 | - | 99 | 45 | - | IP 34 | 37 | - | 60 | - | 14.26 | 220V / 60Hz | 100 | - | - | - | 100 | axial | exhaust | - | wall mounting , ceiling mounting | - | - | - | - | - |
- | - | - | - | - | 220 | 0.097 | - | 90 | 45 | - | IP 24 | 37 | - | 60 | - | 14.82 | 220V / 60Hz | 100 | - | - | - | 100 | axial | exhaust | - | wall mounting , ceiling mounting | - | - | - | - | - |
- | - | - | - | - | 220-240 | 0.085 | 2300 | 98 | - | 0.64 | IP 34 | 34 | - | 50/60 | - | 14 | - | 100 | - | 220-240V / 50-60Hz | - | 100 | axial | exhaust | - | wall mounting , ceiling mounting | - | - | - | - | - |
- | - | - | - | - | 12 | 1.7 | 2300 | 165 | - | 0.99 | IP 24 | 34 | - | 50/60 | - | 22 | - | 125 | - | 12V / 50-60Hz | - | 125 | axial | exhaust | - | wall mounting , ceiling mounting | - | - | - | - | - |
- | - | - | - | - | 220-240 | 0.1 | 2400 | 185 | - | 0.7 | IP 34 | 35 | - | 50/60 | - | 16 | - | 125 | - | 220-240V / 50-60Hz | - | 125 | axial | exhaust | - | wall mounting , ceiling mounting | - | - | - | - | - |
- | - | - | - | - | 220-240 | 0.105 | 2400 | 232 | - | 0.72 | IP 34 | 37 | - | 50/60 | - | 22 | - | 125 | - | 220-240V / 50-60Hz | - | 125 | axial | exhaust | - | wall mounting , ceiling mounting | - | - | - | - | - |
- | - | - | - | - | 220-240 | 0.059 | - | - | - | 0.63 | IP 34 | 31 | - | 50/60 | - | 9.1 | - | 125 | - | 220-240V / 50-60Hz | - | 125 | axial | exhaust | - | wall mounting , ceiling mounting | - | - | - | 152 | - |
- | - | - | - | - | 12 | 1.5 | 2200 | 77 | - | 0.59 | IP 34 | 32 | - | 50/60 | - | 14 | - | 100 | - | 12V / 50-60Hz | - | 100 | axial | exhaust | - | wall mounting , ceiling mounting | - | - | - | - | - |
- | - | - | - | - | 220-240 | 0.1 | 2400 | 185 | - | 0.48 | IP 24 | 38 | - | 50/60 | - | 16 | - | 125 | - | 220-240V / 50-60Hz | - | 125 | axial | exhaust | - | wall mounting , ceiling mounting | - | - | - | - | - |
- | - | - | - | - | 220-240 | 0.1 | 2400 | 185 | - | 1 | IP 24 | 35 | - | 50/60 | - | 22 | - | 125 | - | 220-240V / 50-60Hz | - | 125 | axial | exhaust | - | wall mounting , ceiling mounting | - | - | - | - | - |
- | - | - | - | - | 230 | 0.05 | 2000 | 85 | - | 0.51 | IP 44 | 25 | - | 50 | - | 7.5 | - | 100 | - | - | - | - | axial | exhaust | - | wall mounting , ceiling mounting | - | - | - | - | - |
- | - | - | - | - | 120-240 | 0.24 (0.39) | 1100 | 254 | - | - | IP X4 | 23...29 | - | 50/60 | - | 26 | - | - | 2 х 10 | - | C | - | - | - | - | - | 0.37 | 71 | - | - | - |
- | - | - | - | - | 220-240 | 0.049 | - | 97 | - | 0.55 | IP X4 | 25 | - | 60 | - | 7.5 | - | - | - | - | - | 100 | axial | exhaust | - | wall mounting , ceiling mounting | - | - | - | - | - |
127 V | - | - | - | - | 127 | 0.115 | 2500 | 92 | - | 0.55 | IP 34 | 34 | - | 60 | - | 10 | - | 100 | - | - | - | 100 | axial | exhaust | - | wall mounting , ceiling mounting | - | - | - | - | - |
220 V | - | - | - | - | 220 | 0.054 | 2500 | 92 | - | 0.55 | IP 34 | 34 | - | 60 | - | 9 | - | 100 | - | - | - | 100 | axial | exhaust | - | wall mounting , ceiling mounting | - | - | - | - | - |
- | - | - | 2400 | - | 220-240 | 0.13 | - | 295 | - | 0.89 | IP 34 | 39 | - | 60 | - | 24 | - | 150 | - | - | - | 150 | axial | exhaust | - | wall mounting , ceiling mounting | - | - | - | - | - |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Square | - | - | - | - | - | - | - | - | - | ABS plastic | - | - | - | 180х180 | - | 100 Ace , 125 Ace , 100 Base , 125 Base , MV 100 FB , F4 100 FB |
- | - | - | - | - | 220-240 | 0.1 | 2400 | 179 | - | 0.73 | IP 24 | 35 | - | 50 | - | 17 | - | 120 | - | 220-240V / 50Hz | - | 120 | axial | exhaust | - | wall mounting , ceiling mounting | - | - | - | - | - |
- | - | - | - | - | 12 | 1.5 | 2200 | - | - | - | IP 34 | 32 | 0.59 | 50 | - | 14 | - | 100 | - | 12V / 50Hz | - | 100 | axial | exhaust | - | wall mounting , ceiling mounting | - | - | - | 77 | - |
speed 1 | 220-240 | 75 | - | 2.7 | - | 0.11 | - | - | - | - | IP 55 | 29 | - | 50 | - | 24 | - | 80 | - | 220-240V / 50Hz | - | 80 | centrifugal | exhaust | - | wall mounting , ceiling mounting | 1.15 | 21 | - | - | - |
speed 2 | 220-240 | 100 | - | 2.7 | - | 0.13 | - | - | - | - | IP 55 | 38 | - | 50 | - | 29 | - | 80 | - | 220-240V / 50Hz | - | 80 | centrifugal | exhaust | - | wall mounting , ceiling mounting | 1.04 | 28 | - | - | - |
- | - | - | - | - | 220-240 | 0.13 | 2400 | 302 | - | 1.08 | IP 24 | 39 | - | 50; 60 | - | 29 | - | 150 | - | 220-240V / 50Hz or 220-240V / 60Hz | - | 150 | axial | exhaust | - | wall mounting , ceiling mounting | - | - | - | - | - |
TO COMPLETE THE REGISTRATION CLICK ON THE LINK SENT YOU BY EMAIL
x
Your registration has been successfully completed. Enter your details in the login form in the Personal Area.
x
Your message
was successfully sent x
was successfully sent x
Check your inbox for further instructions
x
Share your opinion
Questionnaire
How often do you use equipment selection program?