VENTS TT Silent-M 150
Inline mixed-flow fans in sound- and heat-insulated casing with the air flow up to 555 m³/h.
- Description
- Characteristics
- Capacity diagram
- Downloads
- Dimensions
- Additional diagrams
- BIM
- Designation key
Description
Description
APPLICATION | |
|
|
DESIGN | |
|
|
|
|
MOTOR | |
|
|
CONTROL | |
|
|
TT Silent-M fan with a three-position speed switch | |
|
|
TT Silent-M fan with a built-in speed controller | |
MOUNTING | |
|
|
THE FAN WITH ELECTRONIC MODULE OF THE TEMPERATURE SENSOR AND SPEED CONTROLLER («U» OPTION) | |
|
|
The front panel of the electronic module has the following control knobs: | |
|
|
The fan is available in two modifications: | |
|
|
CONTROL LOGIC OF THE FAN WITH THE ELECTRONIC TEMPERATURE AND SPEED CONTROL MODULE | |
|
|
There are two switch delay control logics for various cases: | |
|
|
Characteristics
Characteristics
Parameter |
TT Silent-M 150 min |
TT Silent-M 150 max |
Measurement unit |
---|---|---|---|
Speed | min | max | - |
Phase | 1 | 1 | ˜ |
Voltage | 230 | 230 | V |
Frequency | 50/60 | 50/60 | Hz |
Fan power | 45 | 52 | W |
RPM | 1970 | 2645 | min-1 |
Current | 0.20 | 0.23 | A |
Maximum air capacity | 405 | 555 | m³/h |
Max. transported air temperature | 60 | 60 | °С |
Sound pressure level at 3 m | 26 | 33 | dBА |
Protection rating | IP X4 | IP X4 | - |
Duct diameter | 150 | 150 | mm |
Sound- and heat-insulated casing | yes | yes | - |
Casing material | polymer coated steel | polymer coated steel | - |
Weight | 6.1 | 6.1 | kg |
SEC Class | C | C | - |
Duct | for round air ducts | for round air ducts | - |
Type | supply and exhaust | supply and exhaust | - |
Mounting | floor mounting, wall mounting, ceiling mounting, Inline | floor mounting, wall mounting, ceiling mounting, Inline | - |
* | To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). | To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). | - |
Capacity diagram
Capacity diagram
- Selection method:
- Air flow:
- Pressure:
Operating point
- Air flow: --
- Pressure: ---
Files archieve
Downloads
Select document type
"TT-M, TT-MD, TT-MD EC, TT Silent-M, TT Silent-MD, TT Silent-MD EC" user's manual 06-2018 (V135EN-03) (pdf 3.41Mb)
Dimensions
Characteristics
Parameter | Value | Measurement unit |
---|---|---|
∅D | 147 | mm |
B | 247 | mm |
B1 | 274 | mm |
H | 260 | mm |
L | 580 | mm |
Additional diagrams
Additional diagrams
Low speed | Gen. | Octave-frequency band [Hz] | LpA, 3 m dBA | LpA, 1 m dBA | ||||||||
Sound-power level | dBA | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 | |||
LwA to inlet | dBA | 59 | 32 | 49 | 55 | 53 | 52 | 38 | 28 | 15 | 38 | 48 |
LwA to outlet | dBA | 62 | 36 | 41 | 44 | 61 | 53 | 44 | 44 | 29 | 41 | 51 |
LwA to environment | dBA | 46 | 37 | 40 | 41 | 40 | 38 | 29 | 22 | 19 | 26 | 36 |
High speed | Gen. | Octave-frequency band [Hz] | LpA, 3 m dBA | LpA, 1 m dBA | ||||||||
Sound-power level | dBA | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 | |||
LwA to inlet | dBA | 68 | 37 | 58 | 65 | 62 | 61 | 44 | 33 | 18 | 48 | 58 |
LwA to outlet | dBA | 66 | 38 | 43 | 47 | 65 | 57 | 47 | 47 | 31 | 45 | 55 |
LwA to environment | dBA | 53 | 44 | 47 | 48 | 47 | 45 | 34 | 26 | 23 | 33 | 43 |
Designation key
Designation key
|
|
Accessories
Similar products