VENTS VUE 900 PBE EC

  • Description
  • Characteristics
  • Capacity diagram
  • Downloads
  • Dimensions
  • Additional characteristics
  • Designation key
  • Accessories
Description
Description
DESCRIPTION
  • The VUT/VUE PBE EC air handling unit with an electric heater and the VUT/VUE PBW EC air handling unit with a water heater are the fully-featured ventilation units ensuring air filtration, fresh air supply and stale air extraction.
  • The units are suitable for integration into various ventilation and air conditioning networks requiring cost-effective solutions and controllable ventilation.
FILTER
  • To filter the supply and extract air, the unit has two built-in G4 filters.
  • For the VUT/VUE 300/550/900 PBE/PBW EC models, a supply filter with an F7 degree of filtration can be installed as an option.

MOTOR
  • High-efficient electronically-commutated motors with external motor and impellers with backward curved blades.
HEAT EXCHANGER
  • A plate counter-flow polystyrene heat exchanger which returns heat is used in the VUT 300/550/900 PBE/PBW EC units.

  • The VUT 2000/3000 PBE/PBW EC units are equipped with a cross-flow plate heat exchanger made of aluminium.

  • The VUE 300/550/900 PBE/PBW EC units are equipped with enthalpy counter-flow heat exchanger.

BYPASS
  • The units are equipped with a bypass for summer cooling.
HEATER
  • The electric heater (for the VUT/VUE PBE EC unit) or the water heater (for the VUT/VUE PBW EC unit), installed downstream of the heat exchanger.
  • The water heaters are designed for max. operating pressure of 1.0 MPa (10 bar) and max. heat carrier operating temperature of +95 °C.
MOUNTING
  • The unit is designed for indoor mounting.
  • While mounting the unit ensure its correct position to enable condensate collection and drainage.
MODIFICATIONS
  • VUT PBE EC – models with an electric heater and a polystyrene or aluminium heat exchanger.
  • VUE PBE EC – models with an electric heater and an enthalpy heat exchanger.
  • VUT PBW EC – models with a water heater and a polystyrene or aluminium heat exchanger.
  • VUE PBW EC – models with a water heater and an enthalpy heat exchanger.
CASING
  • The heat- and sound-insulated aluzinc casing is internally filled with mineral wool.
AUTOMATION
  • The units are equipped with an integrated automation system.
  • The A21 controller enables integration of the unit into the Smart Home System or BMS (Building Management Systems).
  • To control the unit via Wi-Fi, download the VENTS Home mobile app.
CONTROL AND AUTOMATION
Functions A21
Wi-Fi control via mobile application +
Control via wired remote control panel option (А22)
Control via wired remote LCD control panel option (А25)
Control via wireless remote control panel option (А22 Wi-Fi)
BMS RS-485
Wi-Fi
Ethernet
MODBUS (RTU, TCP)
Service Vents Cloud Server +
Speed selection +
Filter replacement indication according to a filter timer
according to a pressure switch of filter clogging for the units with DTV
Alarm indication full alarm description in the mobile application
Week-scheduled operation +
Bypass auto
manual
Timer +
Boost mode +
Fireplace mode +
Freeze protection cyclic shutdown of the supply fan
through preheating (option)
using a bypass
Cooler connection option
Reheater connection option
Control of minimum supply air temperature +
Humidity control option
CO2 control option
VOC control option
PM2.5 control option
Fire alarm sensor option
*Option. The functionality is available when you purchase the appropriate accessory.
Characteristics
Characteristics
Parameter VUE 900 PBE EC
Measurement unit
Frequency 50/60 Hz
Phase 1 ˜
Voltage 230 V
Maximum unit power without an electric heater 442 W
Electric heater power 3300 W
Maximum unit power with an electric heater 3742 W
Electric heater current 14.3 A
Max. unit current without electric heater 3.1 A
Air capacity 1030 m³/h
Max. unit current with electric heater 17.4 A
RPM 2720 min-1
Transported air temperature -25 ... +40 °С
Sound pressure level at 3 m distance 33 dBА
Heating electric heating -
Casing material aluzinc -
Insulation 20 mm mineral wool -
Filter: extract G4 -
Filter: supply G4 (F7*) -
Connected air duct size 250 mm
Heat recovery efficiency 69-85 %
Weight 111 kg
Heat exchanger type counter-flow -
Heat exchanger material enthalpy -
SEC Class A -
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
"Wireless control system A21" user’s manual 09-2022 (V55-8EN-04) (pdf 415.1Kb)
"VENTS VUT/VUE PBE/PBW EC" product description 01-2023 (pdf 3.14Mb)
Download image "VENTS VUT PBE EC, VUT PBW EC (ErP 2016, 2018)" for your website (png 241.89Kb)
Download high quality image "VENTS VUT PBE EC, VUT PBW EC (ErP 2016, 2018)" (psd 3.63Mb)
"VENTS VUT/VUE PBE EC" user’s manual 07-2023 (V217-3EN-01) (pdf 2.44Mb)
"VENTS VUT/VUE PBW EC" user’s manual 11-2023 (V217-4EN-01) (pdf 2.84Mb)
Download image "VENTS VUT 2000-3000 PBE/PBW EC (ErP 2016, 2018)" for your website (png 292.28Kb)
Download high quality image "VENTS VUT 2000-3000 PBE/PBW EC (ErP 2016, 2018)" (psd 3.85Mb)
"VENTS VUT 2000-3000 PBE EC" user’s manual 10-2023 (V225-1EN-02) (pdf 3.77Mb)
"VENTS VUT 2000-3000 PBW EC" user’s manual 10-2023 (V225-2EN-02) (pdf 4.92Mb)
Dimensions
Characteristics
VENTS VUE 900 PBE EC
Parameter Value Measurement unit
∅D 250 mm
B 1351 mm
B1 1485 mm
H 318 mm
L 1349 mm
L1 1402 mm
Additional characteristics
Additional characteristics
A-weighted sound power level Gen. Octave frequency band, Hz LpA, 3 m dBA LpA, 1 m dBA
dBA 63 125 250 500 1000 2000 4000 8000
LwA to supply inlet dBA 70 29 62 69 58 59 53 45 36    
LwA to supply outlet dBA 80 30 64 72 69 74 73 71 71    
LwA to exhaust inlet dBA 69 28 58 68 59 61 56 48 44    
LwA to exhaust outlet dBA 78 29 60 69 72 70 71 64 70    
LwA to environment dBA 53 33 42 47 49 44 41 39 43 33 43
Designation key
Designation key
Series Rated air flow [m³/h] Mounting modification Bypass Heater type Motor type Service side Control Accessories
VUT: ventilation with heat recovery
VUE: ventilation with energy recovery
300; 550; 900; 2000; 3000 P: suspended B: bypass E: electric
W: water
EC: synchronous electronically commutated motor L: left
R: right
А21 DTV: equipped with a differential pressure switch for controlling the contamination of filters
Accessories
Accessories
Model G4 pocket filter F7 pocket filter G4 panel filter Control panel Wi-Fi controlable control panel LCD control panel Humidity sensor
(0-10 V)
CO2 sensor CO2 sensor with indication Humidity sensor VOC sensor
(0-10 V)
CO2 sensor
(0-10 V)
Humidity sensor
(0-10 V)
VUT 300 PBE EC A21 SFK 208x236x27 G4 SFK 208x236x27 F7 SF 440x128x20 G4 A22 A22 WiFi A25 HV2 CO2-1 CO2-2 HR-S DPWQ 30600 DPWQ 40200 DPWC 11200
VUT 550 PBE EC A21 SFK 392x236x27 G4 SFK 392x236x27 F7 SF 782x128x20 G4
VUT 900 PBE EC A21 SFK 647x274x27 G4 SFK 647x274x27 F7 SF 647x274x20 G4
VUE 300 PBE EC A21 SFK 208x236x27 G4 SFK 208x236x27 F7 SF 440x128x20 G4
VUE 550 PBE EC A21 SFK 392x236x27 G4 SFK 392x236x27 F7 SF 782x128x20 G4
VUE 900 PBE EC A21 SFK 647x274x27 G4 SFK 647x274x27 F7 SF 647x274x20 G4
VUT 2000 PBE EC A21 SF 708x480x48 G4
VUT 3000 PBE EC A21 SF 827x741x48 G4
VUT 550 PBW EC A21 SFK 392x236x27 G4 SFK 392x236x27 F7 SF 782x128x20 G4
VUT 900 PBW EC A21 SFK 647x274x27 G4 SFK 647x274x27 F7 SF 647x274x20 G4
VUE 550 PBW EC A21 SFK 392x236x27 G4 SFK 392x236x27 F7 SF 782x128x20 G4
VUE 900 PBW EC A21 SFK 647x274x27 G4 SFK 647x274x27 F7 SF 647x274x20 G4
VUT 2000 PBW EC A21 SF 708x480x48 G4
VUT 3000 PBW EC A21 SF 827x741x48 G4

 

Model Kitchen hood Hydraulic U-trap Silencers Backdraft damper Air damper Clamps Electric actuators Mixing unit
VUT 300 PBE EC A21 KH-1 SH-32 SR 160 600/900/1200 SRF 160 600/900/1200 KOM 160 KRV 160 C 160 LF230 TF230
VUT 550 PBE EC A21 SR 200 600/900/1200 SRF 200 600/900/1200 KOM 200 KRV 200 C 200
VUT 900 PBE EC A21 SR 250 600/900/1200 SRF 250 600/900/1200 KOM 250 KRV 250 C 250
VUE 300 PBE EC A21 SR 160 600/900/1200 SRF 160 600/900/1200 KOM 160 KRV 160 C 160
VUE 550 PBE EC A21 SR 200 600/900/1200 SRF 200 600/900/1200 KOM 200 KRV 200 C 200
VUE 900 PBE EC A21 SR 250 600/900/1200 SRF 250 600/900/1200 KOM 250 KRV 250 C 250
VUT 2000 PBE EC A21 SH-32 SR 315 600/900/1200 SRF 315 600/900/1200 KOM 315 KRV 315 C 315
VUT 3000 PBE EC A21 SR 400 600/900/1200 KOM 400 KRV 400 C 400
VUT 550 PBW EC A21 SR 200 600/900/1200 SRF 200 600/900/1200 KOM 200 KRV 200 C 200 USWK
VUT 900 PBW EC A21 SR 250 600/900/1200 SRF 250 600/900/1200 KOM 250 KRV 250 C 250
VUE 550 PBW EC A21 SR 200 600/900/1200 SRF 200 600/900/1200 KOM 200 KRV 200 C 200
VUE 900 PBW EC A21 SR 250 600/900/1200 SRF 250 600/900/1200 KOM 250 KRV 250 C 250
VUT 2000 PBW EC A21 SH-32 SR 315 600/900/1200 SRF 315 600/900/1200 KOM 315 KRV 315 C 315
VUT 3000 PBW EC A21 SR 400 600/900/1200 KOM 400 KRV 400 C 400
Share your opinion