Equipment selection

x x м
м 3
м/час
Categories
All subcategories
  • Fans for round ducts
  • Fans for rectangular ducts
  • Special fans
  • Sound-insulated fans
  • Centrifugal fans
  • Axial fans
  • Roof fans
Additionally
Show ×
Air capacity
Mounting
Type
Design
Duct
Sound-insulated casing
Outdoor mounting
Casing material
Height
Width
EC motor
Duct diameter
Hide filters
Error
%
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Print version
Search results
Selected products
Mode PowerCurrentVoltagePower consumptionCurrentMaximum air capacity RPMSound pressure level at 3 m distanceMaximum transported air temperatureProtection ratingWeightARPMNoise level at 3 mSpigot sizePhaseNumber of polesSound- and heat-insulated casing Impeller diameterImpeller widthFrequency SpeedCurrentPowerRPMAir capacityIP CodeModificationVoltageMaximum air capacity RPMConnected air duct sizeWeightPhaseFilter: extractFilter: supplyPressureFrequencyCurrent Engine TypeCurrentMaximum unit powerMaximum unit currentProtection ratingSEC ClassPowerSEC ClassSEC ClassMotor protection ratingDuct diameterEC motorWidthHeightCasing materialOutdoor mountingSound-insulated casingDuctDesignTypeMountingSmoke removalMaximum air capacityCurrentMax. transported air temperatureCurrentSound pressure level at 3 m distanceInsulationHeat recovery efficiencyHeat exchanger typeHeat exchanger materialLow-powered motorHighpowered motorHigh-power versionSound- and heat-insulated casing Low-powered motorExternal rotorHigh powered external rotor motorTwo-speed with external rotorDouble-speed motorLow noise and low-powered motorPM 2.5 filtration efficiencyTransported air temperatureAir capacityTurbine protection rating*
- - - 230 32 - 350 1335 37 - IP X2 7.8 - - - - 1 - - - - 50 - - - - - - FFK - - - - - - - - - - - - - - - - - - - - - 125 - - - galvanized steel - - for round air ducts centrifugal supply for chimney - - 0.14 150 - - - - - - - - - yes - yes no no - - - - - - -
50 Hz - - 1~ 220-240 64 - 455 2780 44 - IP X4 3.2 - - - - - - - - - 50 - - - - - - - - - - - - - - - - - - - - - - - C - - - IP44 150 - - - galvanized steel yes - for round air ducts centrifugal - outdoor mounting , wall mounting , Inline - - 0.29 -25 +50 - - - - - - no - - - - - - - - - - - - - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
60 Hz - - 1~ 220-240 78 - 475 3216 45 - IP X4 3.2 - - - - - - - - - 60 - - - - - - - - - - - - - - - - - - - - - - - - - - - IP44 150 - - - galvanized steel yes - for round air ducts centrifugal - outdoor mounting , wall mounting , Inline - - 0.34 -25 +50 - - - - - - no - - - - - - - - - - - - - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
- - - 400 250 - 1275 1415 66 25 +40 IP X4 29 - - - 400х200 3 4 1 - - 60 - - - - - - - - - - - - - - - 387.5 - - 220V / 60Hz - - - - - - - - - - - 400 200 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - 120 - - 399 - 56 - - - - - - 125 - - - - - 60 - - - - - - - - - - - - - - - 510.1 - - 220V / 60Hz - - - - - - - - - 125 no - - plastic - no for round air ducts centrifugal , Inline - - - - - - - - - - - - - - - - - - - - - - - - -
- - - 200-277 - - - - 49 - - 16 - 2600 - - 1 - - - - 50/60 - - - - - - - - - - - - - - - - - 1.72 - - - - IPX4 - 391 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -20 … +60 3100 IP54 -
- - - 230 810 - 2000 1330 63 - IP X4 16.3 - - - - 1 4 - 250 102 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - polymer coated steel yes - for round air ducts , for rectangular air ducts centrifugal - outdoor mounting , wall mounting - - 3.65 -40 +70 - - - - - - - - - - - - - - - - - - - - -
- - - 230 419 - - 870 42 - IP X4 56 - - - - 1 6 - - - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 600 300 galvanized steel - - for rectangular air ducts centrifugal - Inline - - 2.05 - - - - - - - - - - yes - - - - - - - -20 … +70 2260 - -
50 Hz - - 400 250 - 5280 1360 56 - IP X4 9.1 - - - - 3 - - - - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 0.6 - - - - - - - - - - - - - - - - - - - -
60 Hz - - 400 275 - 5350 1620 56 - IP X4 9.1 - - - - 3 - - - - 60 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 0.65 - - - - - - - - - - - - - - - - - - - -
min - - 230 34 - 160 700 14 - IP X4 16.5 - - - - - - - - - 50 min - - - - - - - - - - - - - - - - - - - - - - C - - - - 100 - - - polymer coated steel - yes for round air ducts - supply wall mounting , ceiling mounting - - 0.15 - - - - - - - - - - - - - - - yes no 98 - - - -
max - - 230 42 - 190 1200 23 - IP X4 16.5 - - - - - - - - - 50 max - - - - - - - - - - - - - - - - - - - - - - C - - - - 100 - - - polymer coated steel - yes for round air ducts - supply wall mounting , ceiling mounting - - 0.19 - - - - - - - - - - - - - - - yes no 97 - - - -
- - - 230 - - 600 3390 38 - IP X4 6.0 - - - - 1 - - - - 50/60 - - - - - - - - - - - - - - - - - - - - - - - B 55 - - - - - - - - - - - - - - - - - -25...+55 0.48 - - - - - - - - - - - - - - - - - - - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
- - - - - - - - 30-45 - - 83 - - - - - - - - - - - - - - - - - 220-240 810 2860 250 - 1 G4 G4 , F7 - 50/60 - - - 334 2.2 - - - A - - - - - - aluzinc - - - - - - - - - - - - 25 mm mineral wool 74...93 counter-flow enthalpy - - - - - - - - - - - - - - -
- - 0.76 - - - - - 40 - IP X4 - - - - - - - - - - - - - 85 - 454 - - 200-277 - 3600 - 12 1 - - - 50/60 - - - - - - - - B - - 160 yes - - aluzinc no yes for round air ducts centrifugal supply and exhaust Inline - - - - - - - - - - - - - - - - - - - - - -25 ... +55 - - -
- - - 230 92.6 - - 3200 - - IP X4 - - - - - 1 - - - - 50/60 - 0.75 - - - - - - - - - - - - - - - - - - - - - C - - - - 125 yes - - galvanized steel - - for round air ducts centrifugal supply and exhaust Inline - - - -25 +60 - 34 - - - - - - - yes - - - - - - - - 357 - -
- 49 - - - - - - - - - - 0.22 1400 45 - - 4 - - - - - - - - - IP X4 - 230 - - - 7 1 - - - 50 - - - - - - - - - B IP44 - no - - - yes no - centrifugal exhaust for roof - - - - - - - - - - - - - - - - - - - - - -25 ... +50 738 - -
- - - 400 1508 - - 1440 58 - IP X4 54 - - - - 3 4 - - - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 800 500 galvanized steel - - for rectangular air ducts centrifugal supply and exhaust Inline - - 2.71 - - - - - - - - - - - - - - - - - - -30 … +60 7800 - -
- - - 1~ 220-240 - - 700 - 39 - IP X4 - - - - - - - - - - 50/60 - - - 3700 - - - - - - - - - - - - - - - 0.48 - - - - 54 - - IP44 150 - - - polymer - - for round air ducts mixed-flow - Inline - 194 - -25...+55 - - - - - - - - - - - - - - - - - - - - -
50 Hz - - 220-240 47 - 326 2760 37 - IP X4 2.9 - - - - - - - - - 50 - - - - - - - - - - - - 1 - - - - - - - - - - C - - - - 125 - - - polymer coated steel - - for round air ducts centrifugal supply and exhaust Inline - - 0.25 -25 +45 - - - - - - - - - - - - - - - - - - - - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
60 Hz - - 220-240 54 - 370 3240 38 - IP X4 2.9 - - - - - - - - - 60 - - - - - - - - - - - - 1 - - - - - - - - - - - - - - - 125 - - - polymer coated steel - - for round air ducts centrifugal supply and exhaust Inline - - 0.24 -25 +45 - - - - - - - - - - - - - - - - - - - - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
- - - 400 282 - - 1300 43 - IP X4 29 - - - - 3 4 - - - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 400 200 galvanized steel - - for rectangular air ducts centrifugal - Inline - - 0.60 - - - - - - - - - - yes - - - - - - - -25 ... +45 1470 - -
- - - 230 82 - 360 - 56 25 +55 IP X4 3.2 - - - 125 - - - - - 60 - - - - - - - - - - - - - - - 425 - - 220V / 60Hz - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - 230 34 157 1410 52 40 IP 24 2.5 - - - 150 - - - - - 60 - - - - - - - - - - - - - - - 31.3 - - 220V / 60Hz - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - 230 43 405 1300 32 40 IP 24 3 - - - 200 - - - - - 50 - - - - - - - - - - - - - - - - - - 220В / 50Гц - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - 230 83 - - 2500 47 - IP X4 5.1 - - - - 1 - - - - 50/60 - - - - - - - - - - - - - - - - - - - - - - - B - - - - 200 yes - - polymer coated steel yes - for round air ducts centrifugal supply and exhaust outdoor mounting , Inline - - 0.63 -25 +60 - - - - - - no - no - - - - - - - - - 845 - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
- - - 230 244 - - 910 45 - IP X4 24 - - - - 1 6 - - - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 500 250 galvanized steel - - for rectangular air ducts centrifugal - Inline - - 1.22 - - - - - - - - - - no - - - - - - - -20 … +50 1460 - -
- - - 1~200-277 1250 - 7830 1530 63 - IP X4 - - - - - 1 - - - - 50/60 - - - - - - - - - - - - - - - - - - - - - - - - - - - - 450 yes - - polymer coated steel - - for round air ducts mixed-flow - Inline - - 6.3 -25 +40 - - - - - - - - - - - - - - - - - - - - -
- - - 230 320 - 1515 2615 45 - IP X4 33 - - - - 1 - - - - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - 250 - - - aluzinc - - for round air ducts centrifugal supply and exhaust Inline - - 1.40 -25...+55 - - - - - - - no - yes no - - - - - - - - - -