VENTS 100 LDT Fresh time K 12
- Description
- Characteristics
- Capacity diagram
- Downloads
- Options
- Dimensions
- Wiring plan
Description
Description
APPLICATIONS | |
|
|
DESIGN | |
|
|
MOTOR | |
|
|
CONTROL | |
Manual:
|
Automatic:
|
MOUNTING FEATURES | |
|
|
MOUNTING EXAMPLE | |
Characteristics
Characteristics
Parameter | Value | Measurement unit |
---|---|---|
Voltage | 12 | V |
Frequency | 50/60 | Hz |
Power consumption | 14 | W |
Air capacity | 77 | m³/h |
Current | 1.5 | A |
RPM | 2200 | min-1 |
Sound pressure level at 3 m | 32 | dBА |
Weight | 0.59 | kg |
Spigot size | 100 | mm |
Engine Type | 12V / 50-60Hz | - |
Design | axial | - |
Duct diameter | 100 | mm |
IP Code | IP 34 | - |
Type | exhaust | - |
Mounting | wall mounting , ceiling mounting | - |
Capacity diagram
Capacity diagram
- Selection method:
- Air flow:
- Pressure:
Operating point
- Air flow: --
- Pressure: ---
Files archieve
Downloads
Modifications
Modifications
Modification name | Backdraft damper | Timer | Safe voltage (12 V) | |
---|---|---|---|---|
VENTS 100 LDT Fresh time K 12 |
|
Dimensions
Characteristics
Parameter | Value | Measurement unit |
---|---|---|
Ø D | 100 | mm |
B | 152 | mm |
H | 120 | mm |
L | 135 | mm |
L1 | 40 | mm |
Wiring plan
Wiring plan
Wiring diagram for the fans equipped with a built-in switch | Wiring diagram for the fans without built-in switch |
Wiring diagram for the fans equipped with a timer / timer, humidity sensor and a built-in switch | Wiring diagram for the fans equipped with a timer / timer with a humidity sensor without built-in switch |
Wiring diagram for the fans with a light lamp. Separate activation of the fan and the built-in lamp. | Wiring diagram for the fans with a light lamp. Parallel activation of the fan and the built-in lamp. |
Wiring diagram for the fans with an light lamp and grounding. Separate activation of the fan and the built-in lamp. | Wiring diagram for the fans with a light lamp and grounding. Parallel switching of the fan and the built-in lamp. |
Wiring diagram for the fans with grounding | |
* - only for fans designed for 12 V rated voltage (specified on the fan casing and packing).
S, S1, S2 - external switches.
Operating logic of the fans with optional equipment
- The fan equipped with a timer is activated by the control voltage supplied to LT input. After the control voltage is disconnected the fan continues operating within the time period within 2 to 30 minutes according to the timer settings. The turn-off delay time is adjusted by turning the respective potentiometer T control knob clockwise to increase and counter-clockwise to reduce it.
- The fan equipped with a timer and humidity sensor is activated by the control voltage supplied to LT input or in case of exceeding the preset humidity threshold value adjustable from ~60% to ~90%. After the control voltage is disconnected or as the humidity level H drops below the set threshold the fan continues operating within the time period within 2 to 30 minutes according to the timer settings. The turn-off delay time and the threshold humidity level are adjusted by turning the control knob of the respective potentiometer T for timer and H for humidity sensor clockwise to increase and counter-clockwise to reduce the set value. To set the maximum humidity level (90%) set the potentiometer control knob for H max position.
- The fan equipped with a timer and motion sensor is activated in case of the moving detection at the distance from 1 m to 4 m with 100° detection angle. After motion is off the fan continues operating within the time period within 2 to 30 minutes according to the timer settings. The turn-off delay time is adjusted by turning the respective potentiometer T control knob clockwise to increase and counter-clockwise to reduce it.
- Wiring diagram for connection of the light lamp to the fan timer operated by the common switch is shown on diagram 4. Upon the light lamp disconnection the fan continues operating according to the timer setting within the set time period.
Legend
Legend
Picture symbol | Designation | Modification description | ||
---|---|---|---|---|
LD Fresh time R | Fan with a Roman hour plate. | |||
LD Fresh time К | Fan is equipped with a backdraft damper for back flow preventing. | |||
LD Fresh time L | The motor is equipped with ball bearings for long service life (appr. 40 thousand hours) and fan mounting at any angle. The bearings are maintenance-free and contain enough grease for the entire operating period. | |||
LD Fresh time turbo | High-powered motor. | |||
LD Fresh time 12 | Modification with low-voltage motor. 12 V AC power supply. | |||
LDT Fresh time | Equipped with a regulated timer with the operating time from 2 to 30 minutes. | |||
LDTH Fresh time | Equipped with a timer with the operating time from 2 to 30 minutes and a humidity sensor with the threshold value from 60 to 90%. | |||
LDV Fresh time | Equipped with a pull cord switch. | |||
LDVT Fresh time | Equipped with a pull cord switch and a regulated timer with the operating time adjustable from 2 to 30 minutes. | |||
LDVTH Fresh time | Equipped with a pull cord switch, regulated timer with the operating time adjustable from 2 to 30 minutes and a humidity sensor with the operating threshold range from 60% to 90%. |
Accessories