Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use

VENTS 150 M1TP

  • Description
  • Characteristics
  • Downloads
  • Options
  • Dimensions
  • Wiring plan
Description
Description
APPLICATIONS  
  • Continuous or periodic exhaust ventilation of bathroom, showers, kitchens and other utility spaces.
  • Ventilation shaft mounting or duct connection.
  • Low to medium air flow motion for short distances at low air resistance.
  • Compatible with 100, 125 and 150 mm air ducts.
DESIGN  
  • Modern design and aesthetic look.
  • The casing and the impeller are made of high-quality durable ABS plastic, UV resistant.
  • The intellectual impeller design makes the fan efficiency high and the service life long.
  • Insect screen.
  • Protection rating IP 34.
MOTOR  
  • Reliable and low-watt electric motor.
  • Designed for continuous operation and requires no maintenance.
  • Equipped with overheating protection.
CONTROL  

Manual:

  • The fan is controlled by a room light switch. It is not included in the delivery package.
  • The fan is controlled by the built-in pull cord switch V. Not applied in case of ceiling mounting.
  • Speed control is possible through a thyristor speed controller (see Electrical Accessories). Several fans may connected to the same controller. Speed controllers can not be connected to the fans with TTHTPVTVTH modification.

Automatic:

  • By the electronic control unit BU-1-60 (see Electrical Accessories). The control unit is supplied separately.
  • By the timer (the built-in run-out timer enables the fan operation within 2 to 30 minutes after the fan switching off).
  • By the humidity sensor and timer TH (if the humidity level in the room exceeds the sensor threshold adjustable value within 60-90% the fan switches automatically on and operates until the humidity level drops to the standard level, after that the fan continues operating within the time period according to the timer setting, then shuts down).
  • By the motion sensor and the timer TP (in case of motion detection the fan switches automatically on and operates within the set time period from 2 to 30 minutes. The motion sensitivity area is up to 4 meters and the maximum detection angle is 100°.
MOUNTING FEATURES  
  • The fan is mounted directly into the ventilation shaft.
  • Flexible duct application is recommended in case of remote location of the ventilation shaft. The air duct is connected to the fan exhaust flange through a clamp.
  • Fixed to the wall by self-tapping screws.
  • For 12 V low-voltage motor fan connection to 220 V / 50 Hz power mains use the step-down transformer TRF 220/12-25 that is available upon separate order.

MOUNTING EXAMPLE  
 
Characteristics
Characteristics
Parameter Value Measurement unit
Voltage 220-240 V
Frequency 50; 60 Hz
Power consumption 24 W
Air capacity 295 m³/h
Current 0.13 A
RPM 2400 min-1
Sound pressure level at 3 m 39 dBА
Weight 0.8 kg
Spigot size 150 mm
Engine Type 220-240V / 50Hz or 220-240V / 60Hz -
Design axial -
Duct diameter 150 mm
IP Code IP 34 -
Type exhaust -
Mounting wall mounting , ceiling mounting -
Files archieve
Downloads
Modifications
Modifications
Modification name TimerMotion sensor
VENTS 150 M1TP
+
Dimensions
Characteristics
VENTS 150 M1
Parameter Value Measurement unit
Ø D 150 mm
B 212 mm
B1 196 mm
B2 150 mm
H 195 mm
L 114 mm
L1 33 mm
Wiring plan
Wiring plan
Wiring diagram for the fans equipped with a built-in switch Wiring diagram for the fans without built-in switch
Wiring diagram for the fans equipped with a timer / timer, humidity sensor and a built-in switch Wiring diagram for the fans equipped with a timer / timer with a humidity sensor without built-in switch
Wiring diagram for the fans with a light lamp. Separate activation of the fan and the built-in lamp. Wiring diagram for the fans with a light lamp. Parallel activation of the fan and the built-in lamp.
Wiring diagram for the fans with an light lamp and grounding. Separate activation of the fan and the built-in lamp. Wiring diagram for the fans with a light lamp and grounding. Parallel switching of the fan and the built-in lamp.
Wiring diagram for the fans with grounding  
 

* - only for fans designed for 12 V rated voltage (specified on the fan casing and packing).
S, S1, S2 - external switches.

Operating logic of the fans with optional equipment
  • The fan equipped with a timer is activated by the control voltage supplied to LT input. After the control voltage is disconnected the fan continues operating within the time period within 2 to 30 minutes according to the timer settings. The turn-off delay time is adjusted by turning the respective potentiometer T control knob clockwise to increase and counter-clockwise to reduce it.
  • The fan equipped with a timer and humidity sensor is activated by the control voltage supplied to LT input or in case of exceeding the preset humidity threshold value adjustable from ~60% to ~90%. After the control voltage is disconnected or as the humidity level H drops below the set threshold the fan continues operating within the time period within 2 to 30 minutes according to the timer settings.  The turn-off delay time and the threshold humidity level are adjusted by turning the control knob of the respective potentiometer T for timer and H for humidity sensor clockwise to increase and counter-clockwise to reduce the set value. To set the maximum humidity level (90%) set the potentiometer control knob for H max position.
  • The fan equipped with a timer and motion sensor is activated in case of the moving detection at the distance from 1 m to 4 m with 100° detection angle. After motion is off the fan continues operating within the time period within 2 to 30 minutes according to the timer settings. The turn-off delay time is adjusted by turning the respective potentiometer T control knob clockwise to increase and counter-clockwise to reduce it.
  • Wiring diagram for connection of the light lamp to the fan timer operated by the common switch is shown on diagram 4. Upon the light lamp disconnection the fan continues operating according to the timer setting within the set time period.
Legend
Legend
Picture symbol   Designation   Modification description
  M1 К   Fan is equipped with a backdraft damper for back flow preventing.
  M1 L   The motor is equipped with ball bearings for long service life (appr. 40 thousand hours) and fan mounting at any angle. The bearings are maintenance-free and contain enough grease for the entire operating period.
  М1 turbo   High-powered motor.
  M1 press   5-blade low-noise impeller with improved aerodynamics for higher fan capacity.
  М1 12   Modification with low-voltage motor. 12 V AC power supply.
  M1T   Equipped with a regulated timer with the operating time from 2 to 30 minutes.
  M1TH   Equipped with a timer with the operating time from 2 to 30 minutes and a humidity sensor with the threshold value from 60 to 90%.
  M1V   Equipped with a pull cord switch.
  М1VТ   Equipped with a pull cord switch and a regulated timer with the operating time adjustable from 2 to 30 minutes.
  M1VТН   Equipped with a pull cord switch, regulated timer with the operating time adjustable from 2 to 30 minutes and a humidity sensor with the operating threshold range from 60% to 90%.
  М1ТР   Equipped with a regulated timer and a motion sensor with the sensitivity area from 1 to 4 m and the detection angle up to 100°).
Accessories
Share your opinion

Questionnaire
Basic parameter for domestic fan selection