VENTS 150 VKOk turbo

  • Description
  • Characteristics
  • Downloads
  • Options
  • Dimensions
  • Wiring plan
Description
Description
APPLICATIONS  
  • Continuous or periodic exhaust ventilation of bathroom, showers, kitchens and other utility spaces.
  • Exhaust or supply ventilation depending on the fan mounting type in the system.
  • Designed for PVC ducting systems or flexible ducts.
  • Low to medium air flow motion for short distances at low air resistance.
  • Compatible with Ø 100, 125 and 150 mm air ducts.
DESIGN  
  • The casing and the impeller are made of high-quality durable ABS plastic, UV resistant.
  • The intellectual impeller design makes the fan efficiency high and the service life long.
  • Protection rating IP X4.
MOTOR  
  • Reliable and low-watt electric motor.
  • Designed for continuous operation and requires no maintenance.
  • Equipped with overheating protection.
CONTROL  
Manual: Automatic:
  • The fan is controlled by a room light switch. It is not included in the delivery package.
  • Speed control is possible through a thyristor speed controller (see Electrical Accessories). Several fans may connected to the same controller. Speed controllers can not be connected to the fans with TTHTPVTVTH modification.
  • By the electronic control unit BU-1-60 (see Electrical Accessories). The control unit is supplied separately.
MOUNTING FEATURES  
  • The fan is mounted into a matching duct size. Fastening with clamps in case of flexible duct connection.
  • This series fans have different inlet and exhaust flange diameters to enable attachment of the decorative grille MV to the appropriate intake flange diameter in case of direct installation into the ventilation shaft or instead of the existing ventilation grille.
  • The fan can be mounted on a horizontal or vertical flat surface by a fixing bracket (VKOk model).
  • Two fans can be installed in series for higher performance.
  • For 12 V low-voltage motor fan connection to 220 V / 50 Hz power mains use the step-down transformer TRF 220/12-25 that is available upon separate order.

 

 
    VENTS VKO fan flat ventilation example   VENTS VKOk fan cottage ventilation example  

 

Characteristics
Characteristics
Parameter Value Measurement unit
Voltage 220-240 V
Frequency 50; 60 Hz
Power consumption 29 W
Air capacity 358 m³/h
Current 0.13 A
RPM 2400 min-1
Sound pressure level at 3 m 44 dBА
Weight 0.8 kg
Spigot size 150 mm
Engine Type 220-240V / 50Hz or 220-240V / 60Hz -
Design axial -
Duct diameter 150 mm
IP Code IP X4 -
Type supply and exhaust -
Mounting Inline -
Files archieve
Downloads
Modifications
Modifications
Modification name High-powered fan
VENTS 150 VKOk turbo
+
Dimensions
Characteristics
VENTS 150 VKOk turbo
Parameter Value Measurement unit
Ø D 150 mm
Ø D1 154 mm
B 200 mm
B1 184 mm
H 163 mm
L 108 mm
L1 46 mm
L2 45 mm
L3 29 mm
Wiring plan
Wiring plan
Wiring diagram for the fans equipped with a built-in switch Wiring diagram for the fans without built-in switch
Wiring diagram for the fans equipped with a timer / timer, humidity sensor and a built-in switch Wiring diagram for the fans equipped with a timer / timer with a humidity sensor without built-in switch
Wiring diagram for the fans with a light lamp. Separate activation of the fan and the built-in lamp. Wiring diagram for the fans with a light lamp. Parallel activation of the fan and the built-in lamp.
Wiring diagram for the fans with an light lamp and grounding. Separate activation of the fan and the built-in lamp. Wiring diagram for the fans with a light lamp and grounding. Parallel switching of the fan and the built-in lamp.
Wiring diagram for the fans with grounding  
 

* - only for fans designed for 12 V rated voltage (specified on the fan casing and packing).
S, S1, S2 - external switches.

Operating logic of the fans with optional equipment
  • The fan equipped with a timer is activated by the control voltage supplied to LT input. After the control voltage is disconnected the fan continues operating within the time period within 2 to 30 minutes according to the timer settings. The turn-off delay time is adjusted by turning the respective potentiometer T control knob clockwise to increase and counter-clockwise to reduce it.
  • The fan equipped with a timer and humidity sensor is activated by the control voltage supplied to LT input or in case of exceeding the preset humidity threshold value adjustable from ~60% to ~90%. After the control voltage is disconnected or as the humidity level H drops below the set threshold the fan continues operating within the time period within 2 to 30 minutes according to the timer settings.  The turn-off delay time and the threshold humidity level are adjusted by turning the control knob of the respective potentiometer T for timer and H for humidity sensor clockwise to increase and counter-clockwise to reduce the set value. To set the maximum humidity level (90%) set the potentiometer control knob for H max position.
  • The fan equipped with a timer and motion sensor is activated in case of the moving detection at the distance from 1 m to 4 m with 100° detection angle. After motion is off the fan continues operating within the time period within 2 to 30 minutes according to the timer settings. The turn-off delay time is adjusted by turning the respective potentiometer T control knob clockwise to increase and counter-clockwise to reduce it.
  • Wiring diagram for connection of the light lamp to the fan timer operated by the common switch is shown on diagram 4. Upon the light lamp disconnection the fan continues operating according to the timer setting within the set time period.
Legend
Legend
Picture symbol   Designation   Modification description
    VKOk   Fan with a fixing bracket for flat surface mounting.
  VKO L   The motor is equipped with ball bearings for long service life (appr. 40  thousand hours) and fan mounting at any angle. The bearings are maintenance-free and contain enough grease for the entire operating period.
  VKO turbo   High-powered motor.
  VKO press   5-blade low-noise impeller with improved aerodynamics for higher fan capacity.
  VKO 12   Modification with low-voltage motor. 12 V AC power supply.